 Electric Heating Coil Module (Sizes 1-3)
 
     
CaptiveAire Systems
www.captiveaire.com
     
** Please call for pricing or to purchase **
 
Part # & Description
Lookup Part!  - E1.101
Electric Heat Module. 208V 1 phase, 10 KW maximum - 1 modulating stage, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 15.50" wide and 17.75" tall. 48 Amp service required. 400 to 3,600 cfm's. Sheet metal enclosure included.

Lookup Part!  - E1.201
Electric Heat Module. 208V 1 phase, 20 KW maximum - 5 stages, 1 modulating stage, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 15.50" wide and 17.75" tall. 97 Amp service required. 400 to 3,600 cfm's. Sheet metal enclosure included.

Lookup Part!  - E1.202
Electric Heat Module. 208V 3 phase, 20 KW maximum - 2 modulating stages, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 15.50" wide and 17.75" tall. 56 Amp service required. 400 to 3,600 cfm's. Sheet metal enclosure included.

Lookup Part!  - E1.204
Electric Heat Module. 460V 3 phase, 20 KW maximum - 1 modulating stage, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 15.50" wide and 17.75" tall. 26 Amp service required. 400 to 3,600 cfm's. Sheet metal enclosure included.

Lookup Part!  - E1.351
Electric Heat Module. 208V 1 phase, 35 KW maximum - 6 stages total, 2 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 15.50" wide and 17.75" tall. 168.27 Amp service required. 400 to 3,600 cfm's. Sheet metal enclosure included.

Lookup Part!  - E1.354
Electric Heat Module. 460V 3 phase, 35 KW maximum - 2 modulating stages, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 15.50" wide and 17.75" tall. 42 Amp service required. 400 to 3,600 cfm's. Sheet metal enclosure included.

Lookup Part!  - E1.355
Electric Heat Module. 575V 3 phase, 35 KW maximum - 1 modulating stage, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 15.50" wide and 17.75" tall. 33.68 Amp service required. 400 to 3,600 cfm's. Sheet metal enclosure included.

Lookup Part!  - E1.362
Electric Heat Module. 208V 3 phase, 36 KW maximum - 5 stages total, 1 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 15.50" wide and 17.75" tall. 101 Amp service required. 400 to 3,600 cfm's. Sheet metal enclosure included.

Lookup Part!  - E1.401
Electric Heat Module. 208V 1 phase, 40 KW maximum - 5 stages, 2 modulating stage, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 15.50" wide and 17.75" tall. 193 Amp service required. 400 to 3,600 cfm's. Sheet metal enclosure included.

Lookup Part!  - E1.504
Electric Heat Module. 460V 3 phase, 50 KW maximum - 2 modulating stage, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 15.50" wide and 17.75" tall. 62 Amp service required. 400 to 3,600 cfm's. Sheet metal enclosure included.

Lookup Part!  - E1.724
Electric Heat Module. 460V 3 phase, 72 KW maximum - 5 stages, 1 modulating stage, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 15.50" wide and 17.75" tall. 91 Amp service required. 400 to 3,600 cfm's. Sheet metal enclosure included.

Lookup Part!  - E1.765
Electric Heat Module. 600V 3 phase, 76 KW maximum - 2 modulating stage, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 15.50" wide and 17.75" tall. 80 Amp service required. 400 to 3,600 cfm's. Sheet metal enclosure included.

Lookup Part!  - E2.1004
Electric Heat Module. 460V 3 phase, 100 KW maximum - 6 stages, 2 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 22.63" wide and 23.63" tall. 126 Amp service required. 2,000 to 6,500 cfm's. Sheet metal enclosure included.

Lookup Part!  - E2.1195
Electric Heat Module. 575V 3 phase, 119 KW maximum - 5 stages, 1 modulating stages, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 22.63" wide and 23.63" tall. 120 Amp service required. 2,000 to 6,500 cfm's. Sheet metal enclosure included.

Lookup Part!  - E2.452
Electric Heat Module. 208V 3 phase, 45 KW maximum - 5 stages total, 1 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 22.63" wide and 23.63" tall. 125 Amp service required. 2,000 to 6,500 cfm's. Sheet metal enclosure included.

Lookup Part!  - E2.734
Electric Heat Module. 460V 3 phase, 73 KW maximum - 5 stages total, 1 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 22.63" wide and 23.63" tall. 87.6 Amp service required. 2,000 to 6,500 cfm's. Sheet metal enclosure included.

Lookup Part!  - E2.735
Electric Heat Module. 575V 3 phase, 73 KW maximum - 2 modulating stages, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 22.63" wide and 23.63" tall. 70.26 Amp service required. 2,000 to 6,500 cfm's. Sheet metal enclosure included.

Lookup Part!  - E3.1224
Electric Heat Module. 460V 3 phase, 122 KW maximum - 6 stages total, 2 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 29.50" wide and 29.63" tall. 146.4 Amp service required. 4,000 to 8,000 cfm's. Sheet metal enclosure included.

Lookup Part!  - E3.1225
Electric Heat Module. 575V 3 phase, 122 KW maximum - 5 stages total, 1 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 29.50" wide and 29.63" tall. 117.42 Amp service required. 4,000 to 8,000 cfm's. Sheet metal enclosure included.

Lookup Part!  - E3.1434
Electric Heat Module. 460V 3 phase, 133 KW maximum - 6 stages total, 2 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 29.50" wide and 29.63" tall. 180 Amp service required. 4,000 to 8,000 cfm's. Sheet metal enclosure included.

Lookup Part!  - E3.1755
Electric Heat Module. 575V 3 phase, 175 KW maximum - 6 stages, 2 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 29.50" wide and 29.63" tall. 176 Amp service required. 4,000 to 8,000 cfm's. Sheet metal enclosure included.

Lookup Part!  - E3.522
Electric Heat Module. 208V 3 phase, 52 KW maximum - 6 stages total, 2 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 29.50" wide and 29.63" tall. 144 Amp service required. 4,000 to 8,000 cfm's. Sheet metal enclosure included.

Lookup Part!  - E3.642
Electric Heat Module. 208V 3 phase, 64 KW maximum - 6 stages total, 2 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 29.50" wide and 29.63" tall. 178 Amp service required. 4,000 to 8,000 cfm's. Sheet metal enclosure included.

 
 Electric Heating Coil Module (Size 4)
 
     
CaptiveAire Systems
www.captiveaire.com
     
** Please call for pricing or to purchase **
 
Part # & Description
Lookup Part!  - E4.1684
Electric Heat Module. 460V 3 phase, 168 KW maximum - 6 stages total, 2 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 33.50" wide and 35.63" tall. 201.6 Amp service required. 5,000 to 13,000 cfm's. Sheet metal enclosure included.

Lookup Part!  - E4.1685
Electric Heat Module. 575V 3 phase, 168 KW maximum - 6 stages total, 2 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 33.50" wide and 35.63" tall. 161.7 Amp service required. 5,000 to 13,000 cfm's. Sheet metal enclosure included.

Lookup Part!  - E4.2854
Electric Heat Module. 460V 3 phase, 285 KW maximum - 12 stages, 4 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 33.50" wide and 35.63" tall. 359 Amp service required. 5,000 to 13,000 cfm's. Sheet metal enclosure included.

Lookup Part!  - E4.972
Electric Heat Module. 208V 3 phase, 97 KW maximum - 12 stages total, 4 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 33.50" wide and 35.63" tall. 269 Amp service required. 5,000 to 13,000 cfm's. Sheet metal enclosure included.

 
 Electric Heating Coil Module (Size 5)
 
     
CaptiveAire Systems
www.captiveaire.com
     
** Please call for pricing or to purchase **
 
Part # & Description
Lookup Part!  - E5.1732
Electric Heat Module. 208V 3 phase, 173 KW maximum - 24 stages total, 8 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 42.50" wide and 42.63" tall. 480 Amp service required. 8,000 to 22,000 cfm's. Sheet metal enclosure included.

Lookup Part!  - E5.2574
Electric Heat Module. 460V 3 phase, 257 KW maximum - 12 stages total, 4 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 42.50" wide and 42.63" tall. 308.4 Amp service required. 8,000 to 22,000 cfm's. Sheet metal enclosure included.

Lookup Part!  - E5.2575
Electric Heat Module. 575V 3 phase, 257 KW maximum - 12 stages total, 4 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 42.50" wide and 42.63" tall. 247.35 Amp service required. 8,000 to 22,000 cfm's. Sheet metal enclosure included.

Lookup Part!  - E5.3344
Electric Heat Module. 460V 3 phase, 334 KW maximum - 12 stages, 4 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 42.50" wide and 42.63" tall. 420 Amp service required. 8,000 to 22,000 cfm's. Sheet metal enclosure included.

Lookup Part!  - E5.4155
Electric Heat Module. 575V 3 phase, 415 KW maximum - 12 stages, 4 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 42.50" wide and 42.63" tall. 418 Amp service required. 8,000 to 22,000 cfm's. Sheet metal enclosure included.