Rep Our Products

Are you interested in representing CaptiveAire and selling our products?
Please fill out the following form, and we will contact you soon.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

 
CAH 225 with 84" burner Parts
Motors, Pulleys, & Motor Specific Parts
Motor HP Phs Voltage FLA Shaft Frame Weight RPM Vendor
Lookup Part!  - DTP0154 15.000 3 208-230/380/460 V 40.3-36.4/22.7/18.2 1.625" 254T 231 lbs 1755 Mimco/TECO
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
Lookup Part!  - DTP0204 20.000 3 208-230/460 V 53.7-48.6/24.3 1.625" 256T 269 lbs 1770 Mimco/TECO
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
Lookup Part!  - DTP0254 25.000 3 208-230/460 V 65-58.8/29.4 1.875" 284T 339 lbs 1765 Mimco/TECO
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
Lookup Part!  - 02518OT3H284T-W40 25.000 3 575 V 23.6 1.875" 284 350 lbs 1770 WEG
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
Lookup Part!  - DTP0304 30.000 3 208-230/460 V 76.7-69.4/34.7 1.875" 286T 283 lbs 1770 Mimco/TECO
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
Lookup Part!  - DHP0404 40.000 3 208-230/460 V 102.4-92.6/46.3 2.125" 324T 338 lbs 1770 Mimco/TECO
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
Lookup Part!  - 04018OT3H324T-W40 40.000 3 575 V 38.1 2.125" 324T 443 lbs 1775 WEG
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
Lookup Part!  - 050180T3H326T-W40 50.000 3 575 V 46.8 2.125" 326T 513 lbs 1775 WEG
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
Lookup Part!  - DHP0504 50.000 3 208-230/460 V 128.9-117/58.3 2.125" 326T 440 lbs 1775 Mimco/TECO
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
Lookup Part!  - NP0154 15.000 3 190/208-230/380/460 V 41.8/38.2-34.5/20.9/17.3 1.625" 254T 250 lbs 1765 Mimco/TECO
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
Lookup Part!  - NP0204 20.000 3 190/208-230/380/460 V 55.7/50.8-46/27.8/23 1.625" 256T 287 lbs 1760 Mimco/TECO
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
Lookup Part!  - 02018ET3H256T-W22 20.000 3 575 V 19.3 1.625" 256T 396 lbs 1750 WEG
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
Lookup Part!  - 02518ET3H284T-W22 25.000 3 575 V 23.6 1.875" 284T 412 lbs 1750 WEG
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
Lookup Part!  - NP0254 25.000 3 208-230/460 V 64.3-58.2/29.1 1.875" 284T 358 lbs 1765 Mimco/TECO
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
Lookup Part!  - NP0304 30.000 3 208-230/460 V 75.8-68.6/34.3 1.875" 286T 436 lbs 1765 Mimco/TECO
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
Lookup Part!  - 03018ET3H286T-W22 30.000 3 575 V 28.1 1.875" 286T 450 lbs 1750 WEG
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
Lookup Part!  - 04018ET3H324T-W22 40.000 3 575 V 37.7 2.125" 324T 574 lbs 1750 WEG
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
Lookup Part!  - NP0404 40.000 3 208-230/460 V 102.3-92.6/46.3 2.125" 324T 661 lbs 1770 Mimco/TECO
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
Lookup Part!  - 05018ET3H326T-W22 50.000 3 575 V 47.4 2.125" 326T 595 lbs 1750 WEG
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
Lookup Part!  - NP0504 50.000 3 208-230/460 V 125-113.8/56.9 2.125" 326T 686 lbs 1770 Mimco/TECO
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts

The manufacturer reserves the right to use alternate motors from alternate vendors that meet the operating requirements of the fan but may have slightly different specifications.
Intakes & Intake Parts
Part
Lookup Part! IH7-O-FDH Full downturn intake hood.
Lookup Part! IH7-O-IHNF Intake Hood - 140.25" Width X 69.50" Length X 46.75" Max CFM = 45280
Lookup Part! IH7-O-IH2"EZ Intake Hood Outdoor - 140.25" Width X 69.50" Length X 46.75" Height With 2" EZ Filter Max CFM = 45280
Show parts
Lookup Part! IH7-O-VB2"TA-FDH V-BANK - 140.25" Width X 80" Length X 46.75" Height, Standard 2" TA Filter With Full Downturn Hood MERV 8 Filters
Show parts
Lookup Part! IH7-O-VB2"EZ-IH2"EZ V-BANK - 140.25" Width X 97.5" Length X 46.75" Height, Standard 2" EZ Filter With Intake Hood Max CFM = 45280
Show parts
Lookup Part! IH7-I-VB2"TA V-BANK - 140.25" Width X 28" Length X 46.75" Height for Horizontal Industrial With Standard 2" Pleated Filter MERV 8 Filters Max CFM = 56,000
Show parts
Lookup Part! IH7-I-VB2"TA13 V-BANK - 140.25" Width X 28" Length X 46.75" Height for Horizontal Industrial With Standard 2" Pleated Filter MERV 13 Filters Max CFM = 56,000
Show parts
Lookup Part! IH7-I-VB2"EZ V-BANK - 140.25" Width X 28" Length X 46.75" Height for Industrial Horizontal With Standard 2" EZ Filter Max CFM = 56,000
Show parts
Lookup Part! IH7-O-VB2"TA13-VB2"TA-IHNF V-BANK - 140.25" Width X 80" Length X 46.75" Height, Standard 2" TA Filter With Full Downturn Hood MERV 13 Filters Max CFM = 21,525
Show parts
Lookup Part! IH7-O-VB2"EZ-IHNF V-BANK - 140.25" Width X 95.50" Length X 46.75" Height With Standard 2" EZ Filter And Intake Hood w/ No Filters Max CFM = 50,000
Show parts
Lookup Part! IH7-O-VB2"TA13-IHNF V-BANK - 140.25" Width X 95.50" Length X 46.75" Height With Standard 2" Pleated Filter w/Intake Hood w/No Filters MERV 13 Filters Max CFM = 45,280
Show parts
Lookup Part! IH7-O-VB2"TA-IHNF V-BANK - 140.25" Width X 95.50" Length X 46.75" Height With Standard 2" Pleated Filter w/Intake Hood w/No Filters MERV 8 Filters Max CFM = 45,280
Show parts
Temperature Controls

No Temperature Controls Found.

Gas Manifold Parts

No Gas Manifold Parts Found.

Blower
Part
Lookup Part! A225-25H Two 25" Blowers - Enamel finish, pillow block bearing, 30000-56000, 50 HP, 2 3/16 Shaft, 900 MAX RPM, used in heated and non-heated supply fans
Burner
Part
Lookup Part! R7-9-84 Direct-fired burner assembly. 3,850,000 BTU/HR Maximum, 128,333 minimum. 84" long. Used in sizes 6-9 industrial vertical and horizontal direct-fired heaters. Used for both Natural and Propane Gas. Pilot/Flame Rod/Spark Assembly included.
 
Lookup Part!  - 1190850 - [1 used] BURNER PART - "BRUTE" PILOT ASSEMBLY W/ SPARK & FLAME ROD. Pilot hole size is drill #50 (.070 diameter) (342B) (A0003270) Includes pack of boots and hardware. REPLACES 1190870
 
Lookup Part!  - 1060810 - [2 used] BURNER PART - 12" STRAIGHT BACK INLET SECTION - HMA-2A (Aluminum)
 
Lookup Part!  - 1010810 - [5 used] BURNER PART - 12" STRAIGHT SECTION - HMA-2A (Aluminum)
 
Lookup Part!  - 1372-52 - [2 used] BURNER PART - BLANK END FLANGE - ALUMINUM
 
Lookup Part!  - 1354-50 - [1 used] BURNER PART - SS End Plate
 
Lookup Part!  - 1354-60 - [1 used] BURNER PART - SS End Plate W/ PILOT MOUNT
Replacement Parts
Part
Lookup Part!  - [1 used] PN10-10RX-L Yellow Ring Expanded Entry for GTO Cable - Panduit Used on ignition transformers
Lookup Part!  - [1 used] M7090H1I Floor support for Size 7 Industrial Horizontal units.
Lookup Part!  - [1 used] M7043H1I Vestibule side intake panel for Size 7 Industrial Horizontal units.
Common Heater Components
Lookup Part!  - [1 used] HMI_Bracket 20 GA. Galvanized. Used on IBT controls
Controller&HMI
Lookup Part!  - [1 used] HMI_01_MUA_POPULATED HMI assembly. Preprogrammed for use with MUA Board. Includes CASHMI PCB, 4 mounting screws, 16 ga. SS backing plate, membrane switches & gasket. HMI should have populated RH sensor.
Coupler
Lookup Part!  - [2 used] 2 3/16" BUSHING SF 2 3/16" BUSHING SF will take 2 to make up coupler
Lookup Part!  - [2 used] 11B FLANGE Flange 11B will take two to make up coupler, match with 11E sleeve and SF bushing.
Lookup Part!  - [1 used] 11E SLEEVE SLEEVE 11E will take one to make up coupler. Match with two 11B flanges.
Direct Fired Air Movement Control Components
Lookup Part!  - [4 used] 17045A Airflow Switch Components Cleveland Controls Airflow Probe 4".
Direct Fired Components
Lookup Part!  - [4 used] 85000.002 Standard Lifiting Eye for Industrial Horizontal Heaters Size 2-8, 3/8" plate.
Direct Fired Flame Control Components
Lookup Part!  - [1 used] M4RT1 Fireye Flame Safety Control. Direct replacement for M series 2. Pre-purge preset 5 Sec. PTFI preset 10 Sec. Recycles once only after flame signal loss. Wiring connections are identical to M series 2.
Direct Fired Sheet Metal Components
Lookup Part!  - [1 used] M3BLDRAS Assembled blower acccess door for size 3 and size 7 horizontal industrial unit. Includes hinge, latches, liner and insulation.
Lookup Part!  - [1 used] M3VDRASLA Assembled vestibule acccess door for size 3 horizontal industrial unit. Includes hinge, latches, liner and insulation.
Lookup Part!  - [1 used] M3VDRAS Assembled vestibule acccess door for size 3 horizontal industrial unit. Includes hinge, liner and insulation.
Lookup Part!  - [1 used] M7004H1B Base channel center front used on size 7 industrial horizontal units
Lookup Part!  - [1 used] M7003H1B Base channel center rear used on size 7 industrial horizontal units
Lookup Part!  - [1 used] M7005H1B Base channel center splice used on size 7 industrial horizontal units
Lookup Part!  - [2 used] M7002H1B Base channel end left used on size 7 industrial horizontal units
Lookup Part!  - [2 used] M7001H1B Base channel end right used on size 7 industrial horizontal units
Lookup Part!  - [2 used] M7006H1B Base channel end splice used on size 7 industrial horizontal units
Lookup Part!  - [2 used] M7010H1B Base channel motor support used on size 7 industrial horizontal units
Lookup Part!  - [1 used] M400259B Base frame side used on size 4, 7 and 8 industrial horizontal units
Lookup Part!  - [1 used] M400258B Base side used on size 4, 7 and 8 industrial horizontal units
Lookup Part!  - [1 used] M7089H1I Burner base used on size 7 industrial horizontal units
Lookup Part!  - [1 used] M3040H1W Center wall panel between control vestibule and blower access door, used on size 3 horizontal industrial unit. H1, H2, H2I, H3
Lookup Part!  - [1 used] M300039W Door jam, upper RH used on size 3 and size 7 industrial horizontal units
Lookup Part!  - [1 used] M3046H1W Door jamb lower vestibule, used on size 3 and size 7 horizontal industrial unit.
Lookup Part!  - [1 used] M7031H1B Floor center used on size 7 industrial horizontal units with 25" blowers
Lookup Part!  - [1 used] M7030H1B Floor front used on size 7 industrial horizontal units with 25" blowers
Lookup Part!  - [1 used] M400248B Floor panel back used on size 4 & 8 industrial horizontal units
Lookup Part!  - [1 used] M300120W Heat shield, back wall, used in size 3 and size 7 industrial horizontal units.
Lookup Part!  - [1 used] M300022I Heat shield, vestibule used in size 3 and size 7 industrial horizontal units
Lookup Part!  - [1 used] M3038H1W Lower door jamb blower access door used on size 3 horizontal industrial unit.
Lookup Part!  - [1 used] M1017H1W Pilot access panel for industrial direct fired heaters.
Lookup Part!  - [1 used] M8045H1R Roof support for size 7 & 8 industrial horizontal units
Lookup Part!  - [1 used] M7063H1R Roof support for size 7 & 8 industrial horizontal units
Lookup Part!  - [1 used] M7088H1I Vestibule back for a size 7 horizontal industrial unit
Lookup Part!  - [1 used] M4113H1I Vestibule shelf used on size 4, 5 and 8 industrial horizontal units
Lookup Part!  - [1 used] M7053H1I Vestibule side for a size 7 horizontal industrial unit
Lookup Part!  - [1 used] M7057H1W Wall panel center between blowers for size 7 Industrial Horizontal heater
Lookup Part!  - [1 used] M300029W Wall Panel, back center, used in size 3 and size 7 industrial horizontal units.
Miscellaneous Electrical Parts
Lookup Part!  - [1 used] CAT5_3FT 3 Foot Long CAT5 Cable
Lookup Part!  - [1 used] MUA Board PCB for use in heaters. Used with CAS HMI.
Miscellaneous Heater Components
Lookup Part!  - [1 used] 206525 Yellow Label Sheet Package for Industrial MAUs.
Product Manuals
Lookup Part!  - [1 used] MANUAL INDUST Manual for Industrial Direct Fired Heaters.
Thermostats/Sensors
Lookup Part!  - [2 used] A/CP-DO-240-QC 10K, Type II thermistor with 6" probe. 20' wire leads. (Replaces part# A/CP-DO-120-QC)
Transformers
Lookup Part!  - [1 used] 1092TYPEF Ignition Transformer 120V, 180VA, Output 6000 Volts Used with direct fired heaters
Lookup Part!  - [1 used] BE161640GEK0018 TRANSFORMER - Low 40VA Voltage Transformer Used for 120v Primary and 24v Secondary.
Options
Parts
Lookup Part! AALARM Audible Alarm, 120v,(Alarm sounds on flame failure).
Show parts
Lookup Part! 6631T18 Combustible Gas and Carbon Monoxide Detector 120VAC input. On-Board 10A, 250V Relay and 85db Audible Alarm. 150ppm CO, 17ppm H2, 5000 ppm Methane, 35ppm Propane. (HIC-822). 10,000 cubic feet recommended coverage per detector.
Lookup Part! CODTIL Detector/Alarm Interlock (By Others)
Lookup Part! D4120-DST-1.5 Duct Mounted Smoke Detector For Direct Fired Heater. Complete with detector (D4120) and sampling tube (DST-1.5). Ships Loose.
Show parts
Lookup Part! SMDTIL Smoke Detector Interlock (By Others)
Lookup Part! XBINDTWIN Extra Set of V-Belts For Twin Industrial Units. Only to be ordered as fan option at time fan is ordered.
Lookup Part! EGL-7 Size 7 Industrial Heater Extended Grease Lines
Show parts
Lookup Part! CABHTR100WNC Control panel enclosure heater, includes 100w, 120v heater. Recommended for winter design temperature less than 0°F. Operates on PCB controls in IBT Single Modules or RTU
Show parts
Lookup Part! CABHTR200W Control panel enclosure heater, includes 200w, 120v heater and thermostat (10 degree setting). Requires convenience outlet option (power by others). Recommended for winter design temperature less than 0°F. - Old Controls
Show parts
Lookup Part! BHE Box Hanging Eyes (set of 4) for Industrial Direct Fired Heaters (Sizes 2-8)
Show parts
Lookup Part! NON SILICONE Fan housing assembled without the use of silicone caulk. Primarily used for paint booth applications. Use Acrylic Latex Caulk , P/N A0011848.
Lookup Part! POC Proof of closure option for industrial direct fired heaters. One motorized valve must be included in gas manifold.
Lookup Part! CINSUL-7 Size 7 Industrial Heater Casing Insulation with Steel Liner
Lookup Part! FLINSUL-7 Size 7 Industrial Heater Floor Insulation with Steel Liner
Lookup Part! DNDISINDH7-225-ID Down Discharge Construction Internal Damper Size 7 Horizontal Industrial With two 25" Blowers
Show parts
Lookup Part! Cooling Interlock Cooling Interlock Between Remote Panel and Heater
Lookup Part! CIR-IN Cooling Interlock Relay Mounted in Unit - After Air Proving and Intake Air Stat.
Show parts
Lookup Part! A225SDAD-R 180° Side Discharge Air Diffuser A225
Lookup Part! A225DDAD3W 3-Way Down Discharge Air Diffuser A225
Show parts
Lookup Part! A225DDAD4W 4-Way Down Discharge Air Diffuser A225
Show parts
Lookup Part! DSD-225V Straight Run Diffuser Ductwork for A225 Diffuser. 3 Feet Long, 18ga.
Lookup Part! NON_FUSED_DISC_IND_SEP120 Non-Fused Disconnect Switch for Industrial Make Up Air Units, Sep 120v Connection.
Lookup Part! NON_FUSED_DISC_IND_SP Non-Fused Disconnect Switch for Industrial Make Up Air Units, Single Point Connection.
Lookup Part! PRESSGA15 Gas Pressure Gauge, 0-15PSI, 2.5" Diameter, 1/4" Thread Size
Lookup Part! PRESSGA35 Gas Pressure Gauge, 0-35", 2.5" Diameter, 1/4" Thread Size
Lookup Part! PRESSGA5 Gas Pressure Gauge, 0-5#, 2.5" Diameter, 1/4" Thread Size
Lookup Part! PRESSGA-5-0+15 Gas Pressure Gauge, -5 to +15 Inches Wc., 2.5" Diameter, 1/4" Thread Size
Lookup Part! PRESSGA35 Gas Pressure Gauge, 0-35", 2.5" Diameter, 1/4" Thread Size
Lookup Part! PRESSGA15 Gas Pressure Gauge, 0-15PSI, 2.5" Diameter, 1/4" Thread Size
Lookup Part! GMH-A4-4-4 High Gas Pressure Switch (1" - 20" WC) Factory set at 8" w.c. Replaces part HGP-A.
Lookup Part! LGPSO Low Pressure Gas Switch (1" - 6" WC) Factory set at 2" w.c.
Show parts
Lookup Part! Gas Strainer 1 1/2" Ship Loose Gas Strainer. To be installed upstream of unit connection. 1 1/2" Connection
Show parts
Lookup Part! Gas Strainer 1 1/4" Ship Loose Gas Strainer. To be installed upstream of unit connection. 1 1/4" Connection
Show parts
Lookup Part! Gas Strainer 1" Ship Loose Gas Strainer. To be installed upstream of unit connection. 1" Connection
Show parts
Lookup Part! Gas Strainer 2 1/2" Ship Loose Gas Strainer. To be installed upstream of unit connection. 2 1/2" Connection
Show parts
Lookup Part! Gas Strainer 2" Ship Loose Gas Strainer. To be installed upstream of unit connection. 2" Connection
Show parts
Lookup Part! Gas Strainer 3/4" Ship Loose Gas Strainer. To be installed upstream of unit connection. 3/4" Connection
Show parts
Lookup Part! CLCOMM_REV04 CASLink building monitoring system communications module. Requires internet & field wired ethernet connection or 3G cellular service. Includes Rev 3 Comm Module, RJ45 to modbus converter, 3 FT cat5 cable, and 1 FT of shielded twisted pair.
Show parts
Lookup Part! DDC-IP BACnet Monitoring Remote IP BACnet monitoring for supply fans.
Show parts
Lookup Part! DDC-MSTP BACnet Monitoring Remote MSTP BACnet monitoring
Show parts
Lookup Part! Dry Mode Dry Mode
Show parts
Lookup Part! FECONTAAFS Field Wired Exhaust Contactor After Airflow Switch. Rated 23 Amps. Starts up to (2) Single Phase Motors. 2HP max. 115V, 3HP max. 240V. Starts one Three Phase Motor. 5HP max. 208V, 7.5HP 230v, 15HP max. 460V, 15HP max. 575V or (4) Dry Interlocks. Overload not Included
Show parts
Lookup Part! FECONTBAFS Field Wired Exhaust Contactor Before Airflow Switch. Rated 23 Amps. Starts up to (2) Single Phase Motors. 2HP max. 115V, 3HP max. 240V. Starts one Three Phase Motor. 5HP max. 208V, 7.5HP max 230v, 15HP max. 460V. Overload not Included
Show parts
Lookup Part! FECONTBAFS Field Wired Exhaust Contactor Before Airflow Switch. Rated 23 Amps. Starts up to (2) Single Phase Motors. 2HP max. 115V, 3HP max. 240V. Starts one Three Phase Motor. 5HP max. 208V, 7.5HP max 230v, 15HP max. 460V. Overload not Included
Show parts
Lookup Part! Exhaust on Fire Exhaust on Fire
Lookup Part! FEInterBAFS Relay for Field wired Exhaust Interlock. Located before airflow switch.
Show parts
Lookup Part! LFS Low Fire Start. Allows the burner circuit to energize when the modulation control is in a low fire position.
Lookup Part! MAN RES FSC Manual reset of flame safety controller. Used to meet Canada requirement. Flame safety will not reset on cycle of power. Dips 1,2,3,5 closed, 4, 6 open standard settings.
Lookup Part! OCCUPIED SCHEDULING Occupied Scheduling Defaulted for IBT/RTU.
Lookup Part! OPPSIDE-TWINIH-CTRLS Mount motor and controls on opposite side of heaters with double blowers
Lookup Part! INSUEXPV Supply and exhaust (exhaust by others) proving for industrial make up air units. Includes timed relay, requires field supplied exhaust interlock.
Show parts
Lookup Part! Supply Fan Preset Speed Supply Fan Preset Speed Input to PCB. Field Wired.
Lookup Part! CLOGFILTHMI Clogged Filter Switch with Notification on HMI
Show parts
Lookup Part! CLOGFILT Clogged Filter Switch with Light on Remote Panel
Show parts
Lookup Part! PBCLOGFILT Clogged Filter Switch with Light on Paint Booth Control Panel
Show parts
Lookup Part! Control Vestibule LED Lights Control Vestibule LED Lights Used on Industrial Units.
Show parts
Lookup Part! CVOUTLET GFCI 15 amp Convenience Outlet For Heater Enclosure. Power supply by others - Includes receptacle and J box.
Lookup Part! INDPCVOUTLET GFCI 15 amp Powered Convenience Outlet For Industrial units with 208/230/460 power. Includes receptacle, jbox, cover and transformer. Not available with ship loose vfd.
Show parts
Lookup Part! N.O. Contacts Extra set of N.O. contacts on supply starter.
Lookup Part! Shaft Grounding Ring Option Shaft Grounding Ring Option
Lookup Part! A225DDD-R INS External Down Discharge Insulated Damper for size 7 horizontal industrial units with (2)25" blowers. Includes actuator. Insulated blades and frame. Thermally broken blades. Non-stock option, lead time 6 weeks.
Show parts
Lookup Part! A225DDS-R INS External Side Discharge Insulated Damper for size 7 Horizontal industrial units with (2)25" blowers. Includes actuator. Insulated blades and frame. Thermally broken blades. Non-stock option, lead time 6 weeks.
Show parts
Lookup Part! R7 ID INS Size 7 Horizontal Industrial Heater Insulated Intake Damper. Includes Actuator. Non-stock option, lead time 6 weeks.
Show parts
Lookup Part! A225DD-DM External Discharge CD60 Damper for size 7 industrial units with (2)25" blowers. Includes actuator.
Show parts
Lookup Part! A225DDD-R External Down Discharge CD60 Damper for size 7 horizontal industrial units with (2)25" blowers. Includes actuator.
Show parts
Lookup Part! FIELDDMP(S) Field Supplied Damper(s) Indicated By Others
Lookup Part! A225DDI Internal Down Discharge Damper for size 7 industrial horizontal units with (2) 25" inch blowers. Includes actuators.
Show parts
Lookup Part! A225DDS-R External Side Discharge CD60 Damper for size 7 Horizontal industrial units with (2)25" blowers. Includes actuator.
Show parts
Lookup Part! R7 ID-SL Size 7 Horizontal Industrial Heater Intake Damper. Includes Actuator. SHIPS LOOSE For Mounting at Building Wall.
Show parts
Lookup Part! PB-VFD-BSPC-AB Auto Balance Exhaust VFD Static Pressure Control (preset to: -0.01 and 0.02)
Show parts
Lookup Part! PB-BSPC-AB Auto Balance Exhaust Static Pressure Controls, vfd not included (preset to: -0.01 and 0.02)
Show parts
Lookup Part! PB-VFD-RMP-MB Manual Balance Exhaust VFD Control
Lookup Part! PB-LC Paint Booth Lighting Circuit Switch Only.
Lookup Part! PB-LC-AO Paint Booth Lighting Circuit Switch and Auto Off in Cure Mode.
Lookup Part! PB-PURGE Paint Booth Purge Cycle with Light
Lookup Part! CONSERVETMR Spray mode energy conservation timer, reduces cfm's if spray not active. Factory set for 5 minutes. Requires mau vfd.
Show parts
Lookup Part! ENAM-7 Tan Enamel Coating (exterior walls/roof) For Heaters with 222"-225" blower wheels, includes casing and intakes. Consult factory for other colors. Sherwin Williams p/n F75KXN5809-4347, (AX = A0006229)
Lookup Part! NOSTOVVFD-TWIN-PCB No starter/overloads (PCB Controls) installed in unit, no vav profile package, includes VFD for soft start operation (ship loose is default).
Show parts
Lookup Part! NOSTOVVFD-TWIN No starter/overloads installed in unit, no vav profile package, includes VFD for soft start operation (ship loose is default).
Show parts
Lookup Part! NOSTOV-TWIN No starter/overloads installed in unit, non-fused disconnect switch, vfd for soft start by others, no vav profile package provided.
Show parts
Lookup Part! VAV-PWP7-DCV Size 7 VAV Profile and Wiring Package, For Use With DCV.
Show parts
Lookup Part! VAV-PWP7-ND Size 7 VAV Profile and Wiring Package. No VFD included
Show parts
Lookup Part! VAV-PWP7-ND-NP Size 7 VAV Profile and Wiring Package. No VFD included
Show parts
Lookup Part! VAV-PWPH7-BSPC-PCBMUA Size 7 Horizontal Heater VAV Profile and Wiring Package w/ Building Static Pressure Control used with MUA Board
Show parts
Lookup Part! VAV-PWPH7-403G Size 7 Horizontal Heater VAV Profile and Wiring Package w/ CO Detector (by others) Speed Control
Show parts
Lookup Part! VAV-PWPH7-CSAI-PCB Size 7 Horizontal Heater VAV Profile and Wiring Package w/ Constant Speed Control or Analog Input Control PCB
Show parts
Lookup Part! VAV-PWPH7-CSAI Size 7 Horizontal Heater VAV Profile and Wiring Package w/ Constant Speed Control or Analog Input Control
Show parts
Lookup Part! VAV-PWPH7-M Size 7 Horizontal Heater VAV Profile and Wiring Package w/ Manual Adjustment
Show parts
Lookup Part! VAV-PWPH7-MAN-PCB Size 7 Horizontal Heater VAV Profile and Wiring Package w/ Manual Control PCB
Show parts
Lookup Part! VAV-PWPH7-BSPC Size 7 Horizontal Heater VAV Profile and Wiring Package w/ Building Static Pressure Control
Show parts
Lookup Part! VAV-PWPV7-CSAI Size 7 Vertical Heater VAV Profile and Wiring Package w/ Constant Speed Control or Analog Input Control
Show parts
Lookup Part! FIRESTAT-DISCHARGE- Discharge Firestat. Set to 240°F
Lookup Part! FIRESTAT-DISCHARGE Discharge Firestat for Heaters Set to 240°F - Old Controls
Show parts
Lookup Part! FREEZESTAT Freezestat
Lookup Part! FRSTAT-20 Freezestat With 20' Sensor. Factory set at 35°F and 10 minutes.
Show parts
Lookup Part! FRSTAT-20-LTL Freezestat With 20' Sensor and Low Temp Light on Remote Panel. Factory set at 35°F and 10 minutes.
Show parts
Lookup Part! FRSTAT-20-LTL Freezestat With 20' Sensor and Low Temp Light on Remote Panel. Factory set at 35°F and 10 minutes.
Show parts
Lookup Part! FIRESTAT-INTAKE- Intake Firestat. Set to 135°F
Lookup Part! FIRESTAT-INTAKE Intake Firestat for Heaters Set to 135°F - Old Controls
Show parts
Lookup Part! IBT/DF/RTU Nema 4x remote Space Sensor Nema 4x Remote Room Sensor Option. Wall Mountable 10k Room Sensor Included.
Show parts
Lookup Part! A/CP-D-12"-GD 10k Type 2 Thermistor with 12 Inch Probe
Lookup Part! IBT/RTU remote Space Sensor Remote Room Sensor Option. Wall Mountable 10k Room Sensor and Wire Included.
Show parts
Lookup Part! PRE-PT Pre purge (set at 30 seconds) allowing the blower to purge the inside of the heater.
Lookup Part! R7VBI Size 7 Horizontal Industrial Vbank Insulation Upgrade
Lookup Part! LOADREACTORININD Mount Load Reactor in Industrial Mau (Does not include reactor cost, just mounting).
Lookup Part! SPVCM Unit Mount Static Pressure VFD Control (preset to: -0.01 and 0.02)
Lookup Part! FMSVI-7 Floor Mounted Spring Vibration Isolators for Industrial Size 7 Heaters and Supply Fans. Cannot be used in conjunction with curb.
Show parts
Lookup Part! HSVI-7 Hanging Spring Vibration Isolators for Size 7 Industrial Heaters and Supply Fans. Cannot be used in conjunction with curb.