Rep Our Products

Are you interested in representing CaptiveAire and selling our products?
Please fill out the following form, and we will contact you soon.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

 
CAH-M 18 with 24" burner Parts
Motors, Pulleys, & Motor Specific Parts
Motor HP Phs Voltage FLA Shaft Frame Weight RPM Vendor
00218OT3E56Z-S48PP 2.000 3 208-230/415/460 V 5.9-5.3/3/2.6 0.875" 56 40 lbs 1700 WEG
ODP (Open Drip Proof) Pulleys
Show parts
CK56HB02B01-60HZ 2.000 1 115/208-230 V 16.5/9.5-8.1 0.875" 56HZ 58 lbs 1750 HSSA
ODP (Open Drip Proof) Pulleys
Show parts
00318OT3E56Z-S48PP-50HZ 2.000 3 190/220/380/415 V 6.9/6.7/3.4/3.5 0.875" 56 55 lbs 1410 WEG
ODP (Open Drip Proof) Pulleys
Show parts
00318OS1C184T 3.000 1 208-230 V 18.6-17.5 1.125" 184T 73 lbs 1745 Weg
ODP (Open Drip Proof) Pulleys
Show parts
00518OS1C184T 5.000 1 208-230 V 27.1-24.6 1.125" 184T 99 lbs 1750 Weg
ODP (Open Drip Proof) Pulleys
Show parts
00318OT3E56Z-48PP 3.000 3 208-230/380/460 V 8.7-7.9/4.8/3.9 0.875" 56 55 lbs 1730 WEG
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
DTP0054 5.000 3 190/200-208-230/380/400/415/460 V 17/15.6-15-13.6/8.5/7.7/7.5/6.8 1.125" 184T 77 lbs 1750 Mimco/TECO
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
DTP7/54 7.500 3 200-208-230/380/400/460 V 21.5-21.1-19.1/11.4/10.8/9.6 1.375" 213T 104 lbs 1750 Mimco/TECO
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
DTP0104 10.000 3 190/208-230/380/460 V 29.9/27-24.4/15/12.2 1.375" 215T 143 lbs 1755 Mimco/TECO
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
131509 2.000 1 115/208-230 V 24.8/13-12.4 1.125" 182T 75 lbs 1740 Leeson/Rempfer & Assoc.
TEFC (Totally Enclosed Fan Cooled) Pulleys
Show parts
NP0024 2.000 3 208-230/460 V 6.2-5.6/2.8 0.875" 145T 65 lbs 1740 Mimco/TECO
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
00218ET3H145T-W22 2.000 3 575 V 2.2 0.875" 145T 54 lbs 1750 WEG
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
00318ET3H182T-W22 3.000 3 575 V 3.1 1.125" 182T 94 lbs 1750 WEG
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
NP0034 3.000 3 208-230/460 V 8.5-7.7/3.8 1.125" 182T 81 lbs 1755 Mimco/TECO
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
NP0054 5.000 3 190/208-230/460 V 14.8/13.5-12.2/6.1 1.125" 184T 89 lbs 1745 Mimco/TECO
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
00518ET3H184T-W22 5.000 3 575 V 5.1 1.125" 184T 104 lbs 1750 WEG
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
00718ET3H213T-W22 7.500 3 575 V 7.3 1.375" 213T 174 lbs 1750 WEG
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
01018ET3H215T-W22 10.000 3 575 V 9.9 1.375" 215T 188 lbs 1750 WEG
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts

The manufacturer reserves the right to use alternate motors from alternate vendors that meet the operating requirements of the fan but may have slightly different specifications.
Intakes & Intake Parts
Part
IH2-O-FDH Full Downturn Hood. 56.25" Width, 44" Deep, 40.75" Height
IH2-O-IHNF Intake Hood - 56.25" Width X 69.50" Length X 40.75" Height
Show parts
IH2-O-IH2"EZ Intake Hood Outdoor - 56.25" Width X 69.50" Length X 40.75" With 2" EZ Filter Max CFM = 16000
Show parts
IH2-O-VB2"TA-FDH V-BANK - 56.25" Width X 72" Length X 40.75" Height, Standard 2" TA Filter With Full Downturn Hood MERV 8 Filters
Show parts
IH2-O-VB2"EZ-IH2"EZ V-BANK - 56.25" Width X 97.5" Length X 40.75" Height, Standard 2" EZ Filter With Intake Hood
Show parts
IH2-O-VB2"TA-IH2"EZ V-BANK - 56.25" Width X 97.5" Length X 40.75" Height, Standard 2" TA Filter With Intake Hood MERV 8 Filters
Show parts
IH2-I-VB2"EZ V-BANK - 56.20" Width X 28" Length X 40.75" for Industrial Horizontal With Standard 2" EZ Filter
Show parts
IH2-I-VB2"TA13 V-BANK - 56.25" Width X 28" Length X 40.75" Height for Horizontal Industrial With Standard 2" Pleated Filter MERV 13 Filters
Show parts
IH2-I-VB2"TA V-BANK - 56.25" Width X 28" Length X 40.75" High for Horizontal Industrial, With Standard 2" Pleated Filter MERV 8 Filters
Show parts
IH2-O-VB2"TA13-FDH V-BANK - 56.25" Width X 72" Length X 40.75" Height, Standard 2" TA Filter With Full Downturn Hood MERV 13 Filters
Show parts
IH2-O-VB2"EZ-IHNF V-BANK - 56.25" Width X 96.50" Length X 40.75" With Standard 2" EZ Filter And Intake Hood w/ No Filters
Show parts
IH2-O-VB2"TA13-IHNF V-BANK - 56.25" Width X 96.50" Length X 40.75" With Standard 2" Pleated Filter w/Intake Hood w/No Filters MERV 13 Filters
Show parts
IH2-O-VB2"TA-IHNF V-BANK - 56.25" Width X 96.50" Length X 40.75" With Standard 2" Pleated Filter w/Intake Hood w/No Filters MERV 8 Filters
Show parts
IH2-O-VB2"TA13-VB2"TA-IHNF V-BANK - 56.25" Width X 96.50" Length X 40.75" With Standard 2" Pleated Filter w/Intake Hood w/No Filters MERV 8 Filters
Show parts
IH2-O-VB2"TA13-IH2"EZ V-BANK - 56.25" Width X 97.5" Length X 40.75" Height, Standard 2" TA Filter With Intake Hood MERV 13 Filters
Show parts
Temperature Controls
Part
0-150°F Industrial Recirculating Discharge Temp Control • Heating Activation Based On Intake Set Point • Manual Blower Mode. Use with MUA. (R-RCS-DISCHARGE-INTAKE-0-150-MANUAL-RP-MUA)  
  0-150°F Range Modulating Discharge Temperature Control Unit Maximum Discharge 150°F Discharge Set Point Mounted in Heater Discharge Sensor Mounted in Discharge of Unit Modulating Temperature Control System Designed to Maintain Discharge Temperature Set-Point Heating Activation Based On Intake Set Point Manual Blower Mode Additional HMI Ships Loose  
Show parts
0-150°F Industrial Recirculating Discharge Temp Control • Heating Activation Based On Intake Set Point • Manual Blower Mode.Use with MUA. (R-RCS-DISCHARGE-INTAKE-0-150-MANUAL-MUA)  
  0-150°F Range Modulating Discharge Temperature Control Unit Maximum Discharge 150°F Discharge Set Point Mounted in Heater Discharge Sensor Mounted in Discharge of Unit Modulating Temperature Control System Designed to Maintain Discharge Temperature Set-Point Heating Activation Based On Intake Set Point Manual Blower Mode  
50-90°F Industrial Recirculating Space Temp Control • Heating Activation Based On Either Intake or Space Set Point • Manual Blower Mode. Use with MUA. (R-RCS-SPACE-EITHER-50-90-MANUAL-MUA)  
  50-90°F Range Modulating Space Recirculating Temperature Control Unit Maximum Discharge 120°F Space Sensor Shipped Loose for Room Mounting Modulating Temperature Control System Designed to Maintain Space Temperature Set-Point Heating Activation Based On Either Intake or Space Set Point Manual Blower Mode  
XGFS • PLC PCB • High Temp • Canada (R-GFS-PLC-PCB-0-150-MANUAL-MUA-CANADA)  
  0-150°F Range Modulating Discharge Temperature Control Unit Maximum Discharge 150°F Discharge Set Point Mounted in Heater Discharge Sensor Mounted in Discharge of Unit Modulating Temperature Control System Designed to Maintain Discharge Temperature Set-Point Heating Activation Based On Either Intake or Space Set Point Manual Blower Mode  
Show parts
XGFS • PLC PCB • High Temp • NFPA86 (R-GFS-PLC-PCB-0-150-MANUAL-MUA)  
  0-150°F Range Modulating Discharge Temperature Control Unit Maximum Discharge 150°F Discharge Set Point Mounted in Heater Discharge Sensor Mounted in Discharge of Unit Modulating Temperature Control System Designed to Maintain Discharge Temperature Set-Point Heating Activation Based On Either Intake or Space Set Point Manual Blower Mode  
Show parts
Gas Manifold Parts
Part
Industrial Gas Manifold - 14 in. w.c. - 1 lb., FIA/IRI Insurance Requirement, BV250-1010  
1925000 - 2199999 BTU
Show parts
2200000 - 2474999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., FIA/IRI Insurance Requirement, BV250-66  
0 - 399999 BTU
Show parts
400000 - 549999 BTU
Show parts
550000 - 824999 BTU
Show parts
825000 - 999999 BTU
Show parts
1000000 - 1374999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., FIA/IRI Insurance Requirement, BV250-88  
1375000 - 1649999 BTU
Show parts
1650000 - 1924999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., FM Insurance Requirement, BV250-1010  
1925000 - 2199999 BTU
Show parts
2200000 - 2474999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., FM Insurance Requirement, BV250-66  
0 - 824999 BTU
Show parts
825000 - 1374999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., FM Insurance Requirement, BV250-88  
1375000 - 1649999 BTU
Show parts
1650000 - 1924999 BTU
Show parts
Ind Gas Man - 14 in. w.c. - 1 lb., FM Insurance Requirement with Proof of Closure, BV250-1010  
1925000 - 2199999 BTU
Show parts
2200000 - 2474999 BTU
Show parts
Ind Gas Man - 14 in. w.c. - 1 lb., FM Insurance Requirement with Proof of Closure, BV250-66  
0 - 824999 BTU
Show parts
825000 - 1374999 BTU
Show parts
Ind Gas Man - 14 in. w.c. - 1 lb., FM Insurance Requirement with Proof of Closure, BV250-88  
1375000 - 1649999 BTU
Show parts
1650000 - 1924999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., No Insurance Requirement (ANSI), BV250-1010  
1925000 - 2199999 BTU
Show parts
2200000 - 2474999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., No Insurance Requirement (ANSI), BV250-66  
0 - 549999 BTU
Show parts
550000 - 824999 BTU
Show parts
825000 - 1374999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., No Insurance Requirement (ANSI), BV250-88  
1375000 - 1649999 BTU
Show parts
1650000 - 1924999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., No Insurance Requirement with Proof of Closure, BV250-1010  
1925000 - 2199999 BTU
Show parts
2200000 - 2474999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., No Insurance Requirement with Proof of Closure, BV250-66  
0 - 549999 BTU
Show parts
550000 - 824999 BTU
Show parts
825000 - 1374999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., No Insurance Requirement with Proof of Closure, BV250-88  
1375000 - 1649999 BTU
Show parts
1650000 - 1924999 BTU
Show parts
Industrial Gas Manifold - 1 lb. - 5 lb., FIA/IRI Insurance Requirement, BV250-66  
0 - 399999 BTU
Show parts
400000 - 824999 BTU
Show parts
825000 - 999999 BTU
Show parts
1000000 - 1374999 BTU
Show parts
Industrial Gas Manifold - 1 lb. - 5 lb., FIA/IRI Insurance Requirement, BV250-88  
1375000 - 1649999 BTU
Show parts
1650000 - 2199999 BTU
Show parts
2200000 - 2749999 BTU
Show parts
Industrial Gas Manifold - 1 lb. - 5 lb., FM Insurance Requirement, BV250-66  
0 - 824999 BTU
Show parts
825000 - 999999 BTU
Show parts
1000000 - 1374999 BTU
Show parts
Industrial Gas Manifold - 1 lb. - 5 lb., FM Insurance Requirement, BV250-88  
1375000 - 1649999 BTU
Show parts
1650000 - 2199999 BTU
Show parts
2200000 - 2499999 BTU
Show parts
2500000 - 2749999 BTU
Show parts
Industrial Gas Manifold - 1 lb. - 5 lb., FM Insurance Requirement with Proof of Closure, BV250-66  
0 - 824999 BTU
Show parts
825000 - 999999 BTU
Show parts
1000000 - 1374999 BTU
Show parts
Industrial Gas Manifold - 1 lb. - 5 lb., FM Insurance Requirement with Proof of Closure, BV250-88  
1375000 - 1649999 BTU
Show parts
1650000 - 2199999 BTU
Show parts
2200000 - 2499999 BTU
Show parts
2500000 - 2749999 BTU
Show parts
Industrial Gas Manifold - 1 lb. - 5 lb., No Insurance Requirement (ANSI), BV250-66  
0 - 824999 BTU
Show parts
825000 - 1000000 BTU
Show parts
1000001 - 1374999 BTU
Show parts
Industrial Gas Manifold - 1 lb. - 5 lb., No Insurance Requirement (ANSI), BV250-88  
1375000 - 1649999 BTU
Show parts
1650000 - 2199999 BTU
Show parts
2200000 - 2749999 BTU
Show parts
Industrial Gas Manifold - 1 lb. - 5 lb., No Insurance Requirement with Proof of Closure, BV250-66  
0 - 824999 BTU
Show parts
825000 - 999999 BTU
Show parts
1000000 - 1374999 BTU
Show parts
Industrial Gas Manifold - 1 lb. - 5 lb., No Insurance Requirement with Proof of Closure, BV250-88  
1375000 - 1649999 BTU
Show parts
1650000 - 2199999 BTU
Show parts
2200000 - 2749999 BTU
Show parts
Industrial Gas Manifold - 5 lb. - 10 lb., FIA/IRI Insurance Requirement, BV250-66  
0 - 399999 BTU
Show parts
400000 - 824999 BTU
Show parts
825000 - 999999 BTU
Show parts
1000000 - 1374999 BTU
Show parts
Industrial Gas Manifold - 5 lb. - 10 lb., FIA/IRI Insurance Requirement, BV250-88  
1375000 - 1649999 BTU
Show parts
1650000 - 2199999 BTU
Show parts
2200000 - 2749999 BTU
Show parts
Industrial Gas Manifold - 5 lb. - 10 lb., FM Insurance Requirement, BV250-66  
0 - 824999 BTU
Show parts
825000 - 999999 BTU
Show parts
1000000 - 1374999 BTU
Show parts
Industrial Gas Manifold - 5 lb. - 10 lb., FM Insurance Requirement, BV250-88  
1375000 - 1649999 BTU
Show parts
1650000 - 2199999 BTU
Show parts
2200000 - 2499999 BTU
Show parts
2500000 - 2749999 BTU
Show parts
Industrial Gas Manifold - 5 lb. - 10 lb., FM Insurance Requirement with Proof of Closure, BV250-66  
0 - 824999 BTU
Show parts
825000 - 999999 BTU
Show parts
1000000 - 1374999 BTU
Show parts
Industrial Gas Manifold - 5 lb. - 10 lb., FM Insurance Requirement with Proof of Closure, BV250-88  
1375000 - 1649999 BTU
Show parts
1650000 - 2199999 BTU
Show parts
2200000 - 2499999 BTU
Show parts
2500000 - 2749999 BTU
Show parts
Industrial Gas Manifold - 5 lb. - 10 lb., No Insurance Requirement (ANSI), BV250-66  
0 - 824999 BTU
Show parts
825000 - 999999 BTU
Show parts
1000000 - 1374999 BTU
Show parts
Industrial Gas Manifold - 5 lb. - 10 lb., No Insurance Requirement (ANSI), BV250-88  
1375000 - 1649999 BTU
Show parts
1650000 - 2199999 BTU
Show parts
2200000 - 2749999 BTU
Show parts
Industrial Gas Manifold - 5 lb. - 10 lb., No Insurance Requirement with Proof of Closure, BV250-66  
0 - 824999 BTU
Show parts
825000 - 999999 BTU
Show parts
1000000 - 1374999 BTU
Show parts
Industrial Gas Manifold - 5 lb. - 10 lb., No Insurance Requirement with Proof of Closure, BV250-88  
1375000 - 1649999 BTU
Show parts
1650000 - 2199999 BTU
Show parts
2200000 - 2749999 BTU
Show parts
Industrial Gas Manifold - 7 in. w.c. - 14 in. w.c., FIA/IRI Insurance Requirement, BV250-1010  
1100000 - 1374999 BTU
Show parts
Industrial Gas Manifold - 7 in. w.c. - 14 in. w.c., FIA/IRI Insurance Requirement, BV250-1212  
1375000 - 1649999 BTU
Show parts
Industrial Gas Manifold - 7 in. w.c. - 14 in. w.c., FIA/IRI Insurance Requirement, BV250-66  
0 - 399999 BTU
Show parts
400000 - 549999 BTU
Show parts
Industrial Gas Manifold - 7 in. w.c. - 14 in. w.c., FIA/IRI Insurance Requirement, BV250-88  
550000 - 824999 BTU
Show parts
825000 - 999999 BTU
Show parts
1000000 - 1099999 BTU
Show parts
Industrial Gas Manifold - 7 in. w.c. - 14 in. w.c., FM Insurance Requirement, BV250-1010  
1100000 - 1374999 BTU
Show parts
Industrial Gas Manifold - 7 in. w.c. - 14 in. w.c., FM Insurance Requirement, BV250-1212  
1375000 - 1649999 BTU
Show parts
Industrial Gas Manifold - 7 in. w.c. - 14 in. w.c., FM Insurance Requirement, BV250-66  
0 - 549999 BTU
Show parts
Industrial Gas Manifold - 7 in. w.c. - 14 in. w.c., FM Insurance Requirement, BV250-88  
550000 - 824999 BTU
Show parts
825000 - 1099999 BTU
Show parts
Industrial Gas Manifold - 7 in. w.c. - 14 in. w.c., FM Insurance Requirement with Proof of Closure, BV250-1010  
1100000 - 1374999 BTU
Show parts
Industrial Gas Manifold - 7 in. w.c. - 14 in. w.c., FM Insurance Requirement with Proof of Closure, BV250-1212  
1375000 - 1649999 BTU
Show parts
Industrial Gas Manifold - 7 in. w.c. - 14 in. w.c., FM Insurance Requirement with Proof of Closure, BV250-66  
0 - 549999 BTU
Show parts
Industrial Gas Manifold - 7 in. w.c. - 14 in. w.c., FM Insurance Requirement with Proof of Closure, BV250-88  
550000 - 824999 BTU
Show parts
825000 - 1099999 BTU
Show parts
Industrial Gas Manifold - 7 in. w.c. - 14 in. w.c., No Insurance Requirement (ANSI), BV250-1010  
1100000 - 1374999 BTU
Show parts
Industrial Gas Manifold - 7 in. w.c. - 14 in. w.c., No Insurance Requirement (ANSI), BV250-1212  
1375000 - 1649999 BTU
Show parts
Industrial Gas Manifold - 7 in. w.c. - 14 in. w.c., No Insurance Requirement (ANSI), BV250-66  
0 - 549999 BTU
Show parts
Industrial Gas Manifold - 7 in. w.c. - 14 in. w.c., No Insurance Requirement (ANSI), BV250-88  
550000 - 999999 BTU
Show parts
1000000 - 1099999 BTU
Show parts
Industrial Gas Manifold - 7 in. w.c. - 14 in. w.c., No Insurance Requirement with Proof of Closure, BV250-1010  
1100000 - 1374999 BTU
Show parts
Industrial Gas Manifold - 7 in. w.c. - 14 in. w.c., No Insurance Requirement with Proof of Closure, BV250-1212  
1375000 - 1649999 BTU
Show parts
Industrial Gas Manifold - 7 in. w.c. - 14 in. w.c., No Insurance Requirement with Proof of Closure, BV250-66  
0 - 549999 BTU
Show parts
Industrial Gas Manifold - 7 in. w.c. - 14 in. w.c., No Insurance Requirement with Proof of Closure, BV250-88  
550000 - 824999 BTU
Show parts
825000 - 1099999 BTU
Show parts
Industrial Gas Manifold - 10 lb. or greater w/ High Gas Pressure Regulator, FIA/IRI Insurance Requirement, BV250-66  
0 - 399999 BTU
Show parts
400000 - 824999 BTU
Show parts
825000 - 999999 BTU
Show parts
1000000 - 1374999 BTU
Show parts
Industrial Gas Manifold - 10 lb. or greater w/ High Gas Pressure Regulator, FIA/IRI Insurance Requirement, BV250-88  
1375000 - 1649999 BTU
Show parts
1650000 - 2199999 BTU
Show parts
2200000 - 2749999 BTU
Show parts
Industrial Gas Manifold - 10 lb. or greater w/ High Gas Pressure Regulator, FM Insurance Requirement, BV250-66  
0 - 824999 BTU
Show parts
825000 - 999999 BTU
Show parts
1000000 - 1374999 BTU
Show parts
Industrial Gas Manifold - 10 lb. or greater w/ High Gas Pressure Regulator, FM Insurance Requirement, BV250-88  
1375000 - 1649999 BTU
Show parts
1650000 - 2199999 BTU
Show parts
2200000 - 2499999 BTU
Show parts
2500000 - 2749999 BTU
Show parts
Industrial Gas Manifold - 10 lb. or greater w/ High Gas Pressure Regulator, FM Insurance Requirement with Proof of Closure, BV250-66  
0 - 824999 BTU
Show parts
825000 - 999999 BTU
Show parts
1000000 - 1374999 BTU
Show parts
Industrial Gas Manifold - 10 lb. or greater w/ High Gas Pressure Regulator, FM Insurance Requirement with Proof of Closure, BV250-88  
1375000 - 1649999 BTU
Show parts
1650000 - 2199999 BTU
Show parts
2200000 - 2499999 BTU
Show parts
2500000 - 2749999 BTU
Show parts
Industrial Gas Manifold - 10 lb. or greater w/ High Gas Pressure Regulator, No Insurance Requirement (ANSI), BV250-66  
0 - 824999 BTU
Show parts
825000 - 999999 BTU
Show parts
1000000 - 1374999 BTU
Show parts
Industrial Gas Manifold - 10 lb. or greater w/ High Gas Pressure Regulator, No Insurance Requirement (ANSI), BV250-88  
1375000 - 1649999 BTU
Show parts
1650000 - 2199999 BTU
Show parts
2200000 - 2749999 BTU
Show parts
Industrial Gas Manifold - 10 lb. or greater w/ High Gas Pressure Regulator, No Insurance Requirement with Proof of Closure, BV250-66  
0 - 824999 BTU
Show parts
825000 - 999999 BTU
Show parts
1000000 - 1374999 BTU
Show parts
Industrial Gas Manifold - 10 lb. or greater w/ High Gas Pressure Regulator, No Insurance Requirement with Proof of Closure, BV250-88  
1375000 - 1649999 BTU
Show parts
1650000 - 2199999 BTU
Show parts
2200000 - 2749999 BTU
Show parts
Blower
Part
918M 18" forward curved, centrifugal blower. Pillow-block bearings. Enamel finish framing, G90 housing. 4000-12000 CFM. 1 3/16" x 34" Shaft. 1450 max RPM. Heavy duty angle iron framing. Used in heated and non-heated supply units.
Burner
Part
R1-2-24M Direct-fired burner assembly. 1,300,000 BTU/HR Maximum, 43,333 BTU/HR Minimum. 24" long. Used in sizes 1-9 industrial vertical and horizontal re-circulating direct-fired heaters. Used for both Natural and Propane Gas. Pilot/Flame Rod/Spark Assembly included.
 
HMA-2A-24-4-A
[1 used]
Direct-fired burner assembly. 1,100,000 BTU/HR Maximum, 36,666 BTU/HR Minimum. Aluminum Casting with SS Baffles. 24" long. Used in size 4 commercial direct-fired heater. Used for both Natural and Propane Gas. Pilot/Flame Rod/Spark Assembly included.
Replacement Parts
Part
Common Heater Components
HMI_Bracket
[1 used]
20 GA. Galvanized. Used on IBT controls
Controller&HMI
HMI_01_MUA_POPULATED
[1 used]
HMI assembly. Preprogrammed for use with MUA Board. Includes CASHMI PCB, 4 mounting screws, 16 ga. SS backing plate, membrane switches & gasket. HMI should have populated RH sensor.
Direct Fired Air Movement Control Components
17045A
[4 used]
Airflow Switch Components Cleveland Controls Airflow Probe 4".
Direct Fired Components
85000.002
[4 used]
Standard Lifiting Eye for Industrial Horizontal Heaters Size 2-8, 3/8" plate.
Direct Fired Flame Control Components
M4RT1
[1 used]
Fireye Flame Safety Control. Direct replacement for M series 2. Pre-purge preset 5 Sec. PTFI preset 10 Sec. Recycles once only after flame signal loss. Wiring connections are identical to M series 2.
Direct Fired Sheet Metal Components
M200570I
[2 used]
Motor support hat channel used in size 2 Horizontal Industrial units with all blowers all motors. 5.63 x 32.00 x 12 GA.
M1017H1W
[1 used]
PILOT ACCESS PANEL FOR INDUSTRIAL DIRECT FIRED HEATERS
M1101H1W
[1 used]
Sheet Metal Cover Plate for Industrial Flame Observation Port, used with ASTM-V-7.
M1040H1R
[1 used]
SIZE 1 INDUSTIRIAL HORIZONTAL ROOF 49.91 x 72.75 x 20 GA.
M2BLDRAS
[1 used]
Size 2 Industrial Horizontal Door Blower, assembled, with insulation, hinge, liner and latches. 26.95 x 49.08 x 18 ga.
Miscellaneous Electrical Parts
MUA Board
[1 used]
Printed Circuit board for use in heaters. Used in conjunction with CAS HMI.
Miscellaneous Heater Components
206525
[1 used]
Yellow Label Sheet Package for Industrial MAUs.
Product Manuals
MANUAL INDUST
[1 used]
Manual for Industrial Direct Fired Heaters.
Profile parts-Industrial
M20092AD
[2 used]
Profile bypass damper (14X40) used in Industrial units with 18/20 inch blowers.
Supply Fan Miscellaneous Parts
SB6-4-RIVET
[1 used]
RIVET - 3/16" Diameter, .126 To .250 Grip Range, SB6-4 Button Head Steel/Steel. Replaced 800075.
ITH41234
[1 used]
SHEET METAL SCREWS 12-14 X 3/4"
Thermostats/Sensors
A/CP-DO-240-QC
[2 used]
10K, Type II thermistor with 6" probe. 20' wire leads. (Replaces part# A/CP-DO-120-QC)
Transformers
1092TYPEF
[1 used]
Ignition Transformer 120V, 180VA, Output 6000 Volts Used with direct fired heaters
BE161640GEK0018
[1 used]
TRANSFORMER - Low 40VA Voltage Transformer Used for 120v Primary and 24v Secondary.
Options
Part
ETPRC Electric Two Position Recirculating Damper Control
Show parts
MPRC Manual Potentiometer Re-circulating Damper Control - - Ship loose in 2x4 j-box
Show parts
PRRC Building Automation System Re-circulating Damper Control. Accepts 2-10VDC signal for damper position.
Show parts
SRRDC Schedule damper control - used with the MUA board.
Show parts
SPRC-NP Static Pressure Recirculating Damper Control (Pressure Control By Others)
Show parts
SPRC Static Pressure Recirculating Damper Control (Shipped Loose, preset to: -0.01 and 0.02)
Show parts
SPRCM Static Pressure Recirculating Damper Control (Mounted in Unit, preset to: -0.01 and 0.02)
Show parts
SPRCM-MUA Static Pressure Recirculating Damper Control (Mounted in Unit, preset to: -0.01 and 0.02) Used with MUA board
Show parts
AALARM Audible Alarm, 120v,(Alarm sounds on flame failure).
Show parts
6631T18 Combustible Gas and Carbon Monoxide Detector 120VAC input. On-Board 10A, 250V Relay and 85db Audible Alarm. 150ppm CO, 17ppm H2, 5000 ppm Methane, 35ppm Propane. (HIC-822). 10,000 cubic feet recommended coverage per detector.
CODTIL Detector/Alarm Interlock (By Others)
D4120-DST-1.5 Duct Mounted Smoke Detector For Direct Fired Heater. Complete with detector (D4120) and sampling tube (DST-1.5). Ships Loose.
Show parts
SMDTIL Smoke Detector Interlock (By Others)
XBIND2 Extra Set of V-Belts For Size Two Industrial. Only to be ordered as fan option at time fan is ordered.
EGL-2 Size 2 Industrial Heater Extended Grease Lines
Show parts