WE ARE OPEN | SERVICE, TECH SUPPORT, PARTS, FAST LEAD TIMES FROM 6 LOCAL PLANTS

Rep Our Products

Are you interested in representing CaptiveAire and selling our products?
Please fill out the following form, and we will contact you soon.

0 / 500
0 / 500
0 / 500
0 / 1000

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

 
CAH-M 222 with 96" burner Parts
Motors, Pulleys, & Motor Specific Parts
Click on a part # to order that part.
Motor HP Phs Voltage FLA Shaft Frame Weight RPM Vendor
DTP0154 15.000 3 208-230/380/460 V 40.3-36.4/22.7/18.2 1.625" 254T 231 lbs 1755 Mimco/TECO
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
DTP0204 20.000 3 208-230/460 V 53.7-48.6/24.3 1.625" 256T 269 lbs 1770 Mimco/TECO
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
DTP0254 25.000 3 208-230/460 V 65-58.8/29.4 1.875" 284T 339 lbs 1765 Mimco/TECO
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
DTP0304 30.000 3 208-230/460 V 76.7-69.4/34.7 1.875" 286T 283 lbs 1770 Mimco/TECO
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
DHP0404 40.000 3 208-230/460 V 102.4-92.6/46.3 2.125" 324T 338 lbs 1770 Mimco/TECO
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
01018ET3H215T-W22 10.000 3 575 V 9.9 1.375" 215T 188 lbs 1750 WEG
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
01518ET3H254T-W22 15.000 3 575 V 14.4 1.625" 254T 347 lbs 1750 WEG
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
NP0154 15.000 3 190/208-230/380/460 V 41.8/38.2-34.5/20.9/17.3 1.625" 254T 250 lbs 1765 Mimco/TECO
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
NP0204 20.000 3 190/208-230/380/460 V 55.7/50.8-46/27.8/23 1.625" 256T 287 lbs 1760 Mimco/TECO
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
02018ET3H256T-W22 20.000 3 575 V 19.3 1.625" 256T 396 lbs 1750 WEG
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
02518ET3H284T-W22 25.000 3 575 V 23.6 1.875" 284T 412 lbs 1750 WEG
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
NP0254 25.000 3 208-230/460 V 64.3-58.2/29.1 1.875" 284T 358 lbs 1765 Mimco/TECO
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
NP0304 30.000 3 208-230/460 V 75.8-68.6/34.3 1.875" 286T 436 lbs 1765 Mimco/TECO
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
03018ET3H286T-W22 30.000 3 575 V 28.1 1.875" 286T 450 lbs 1750 WEG
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
04018ET3H324T-W22 40.000 3 575 V 37.7 2.125" 324T 574 lbs 1750 WEG
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
NP0404 40.000 3 208-230/460 V 102.3-92.6/46.3 2.125" 324T 661 lbs 1770 Mimco/TECO
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts

The manufacturer reserves the right to use alternate motors from alternate vendors that meet the operating requirements of the fan but may have slightly different specifications.
Intakes & Intake Parts
Click on a part # to order that part.
Part Per Unit List 
IH7-O-FDH Full downturn intake hood. $2,566.59
IH7-O-IHNF Intake Hood - 140.25" Width X 69.50" Length X 46.75" $1,711.06
IH7-O-IH2"EZ Intake Hood Outdoor - 140.25" Width X 69.50" Length X 46.75" Height With 2" EZ Filter Max CFM = 45281 $1,784.12
Show parts
IH7-O-VB2"TA-FDH V-BANK - 140.25" Width X 80" Length X 46.75" Height, Standard 2" TA Filter With Full Downturn Hood MERV 8 Filters $3,411.18
Show parts
IH7-O-VB2"EZ-IH2"EZ V-BANK - 140.25" Width X 97.5" Length X 46.75" Height, Standard 2" EZ Filter With Intake Hood $3,497.78
Show parts
IH7-I-VB2"TA V-BANK - 140.25" Width X 28" Length X 46.75" Height for Horizontal Industrial With Standard 2" Pleated Filter MERV 8 Filters $1,438.85
Show parts
IH7-I-VB2"TA13 V-BANK - 140.25" Width X 28" Length X 46.75" Height for Horizontal Industrial With Standard 2" Pleated Filter MERV 13 Filters $2,408.20
Show parts
IH7-I-VB2"EZ V-BANK - 140.25" Width X 28" Length X 46.75" Height for Industrial Horizontal With Standard 2" EZ Filter $1,713.69
Show parts
IH7-O-VB2"TA13-VB2"TA-IHNF V-BANK - 140.25" Width X 80" Length X 46.75" Height, Standard 2" TA Filter With Full Downturn Hood MERV 13 Filters $4,380.54
Show parts
IH7-O-VB2"EZ-IHNF V-BANK - 140.25" Width X 95.50" Length X 46.75" Height With Standard 2" EZ Filter And Intake Hood w/ No Filters $3,106.34
Show parts
IH7-O-VB2"TA13-IHNF V-BANK - 140.25" Width X 95.50" Length X 46.75" Height With Standard 2" Pleated Filter w/Intake Hood w/No Filters MERV 13 Filters $3,800.86
Show parts
IH7-O-VB2"TA-IHNF V-BANK - 140.25" Width X 95.50" Length X 46.75" Height With Standard 2" Pleated Filter w/Intake Hood w/No Filters MERV 8 Filters $2,831.49
Show parts
Temperature Controls
Click on a part # to order that part.
Part Per Unit List
0-150°F Industrial Recirculating Discharge Temp Control • Heating Activation Based On Intake Set Point • Manual Blower Mode.Use with MUA. (R-RCS-DISCHARGE-INTAKE-0-150-MANUAL-NEW)  
  0-150°F Range Modulating Discharge Temperature Control Unit Maximum Discharge 150°F Discharge Set Point Mounted in Heater Discharge Sensor Mounted in Discharge of Unit Modulating Temperature Control System Designed to Maintain Discharge Temperature Set-Point Heating Activation Based On Intake Set Point Manual Blower Mode  
Show parts
401M • Series 14 with RCS05 Control System (R-401M-S14-COR-60%/-30/7/90)  
  Maxitrol Series 14 Electronic Modulating Discharge Temperature Control with Remote Panel 40-80°F Discharge Temperature Set-Point Discharge Temperature Set-Point Mounted on Remote Panel Discharge Sensor Mounted in Blower Discharge RCS5 Re-Circulating Heater Control System Minimum Outside Temperature = -30°F, Maximum Discharge Temperature = 90°F Minimum Return Temperature = 7°F, Maximum Return Air % = 60% Controls Recirculating and Outdoor Air Dampers Remote Panel Includes Summer/Off/Winter Switch, and Indicator Lights Modulating Temperature Control System Designed to Maintain Discharge Temperature Set-Point  
Show parts
401M • Series 14 with RCS10 Control System (R-401M-S14-COR-50%/-30/25/120)  
  Maxitrol Series 14 Electronic Modulating Discharge Temperature Control with Remote Panel 40-80°F Discharge Temperature Set-Point Discharge Temperature Set-Point Mounted on Remote Panel Discharge Sensor Mounted in Blower Discharge RCS10 Re-Circulating Heater Control System Minimum Outside Temperature = -30°F, Maximum Discharge Temperature = 120°F Minimum Return Temperature = 25°F, Maximum Return Air % = 50% Controls Recirculating and Outdoor Air Dampers Remote Panel Includes Summer/Off/Winter Switch, and Indicator Lights Modulating Temperature Control System Designed to Maintain Discharge Temperature Set-Point  
Show parts
401M • Series 14 with RCS15 Control System (R-401M-S14-COR-80%/-25/58/90)  
  Maxitrol Series 14 Electronic Modulating Discharge Temperature Control with Remote Panel 40-80°F Discharge Temperature Set-Point Discharge Temperature Set-Point Mounted on Remote Panel Discharge Sensor Mounted in Blower Discharge RCS15 Re-Circulating Heater Control System Minimum Outside Temperature = -25°F, Maximum Discharge Temperature = 90°F Minimum Return Temperature = 58°F, Maximum Return Air % = 80% Controls Recirculating and Outdoor Air Dampers Remote Panel Includes Summer/Off/Winter Switch, and Indicator Lights Modulating Temperature Control System Designed to Maintain Discharge Temperature Set-Point  
Show parts
401M • Series 14 with RCS20 Control System (R-401M-S14-COR-60%/-25/54/120)  
  Maxitrol Series 14 Electronic Modulating Discharge Temperature Control with Remote Panel 40-80°F Discharge Temperature Set-Point Discharge Temperature Set-Point Mounted on Remote Panel Discharge Sensor Mounted in Blower Discharge RCS20 Re-Circulating Heater Control System Minimum Outside Temperature = -25°F, Maximum Discharge Temperature = 120°F Minimum Return Temperature = 54°F, Maximum Return Air % = 60% Controls Recirculating and Outdoor Air Dampers Remote Panel Includes Summer/Off/Winter Switch, and Indicator Lights Modulating Temperature Control System Designed to Maintain Discharge Temperature Set-Point  
Show parts
401M • Series 14 with RCS25 Control System (R-401M-S14-COR-50%/-20/55/140)  
  Maxitrol Series 14 Electronic Modulating Discharge Temperature Control with Remote Panel 40-80°F Discharge Temperature Set-Point Discharge Temperature Set-Point Mounted on Remote Panel Discharge Sensor Mounted in Blower Discharge RCS25 Re-Circulating Heater Control System Minimum Outside Temperature = -20°F, Maximum Discharge Temperature = 140°F Minimum Return Temperature = 55°F, Maximum Return Air % = 50% Controls Recirculating and Outdoor Air Dampers Remote Panel Includes Summer/Off/Winter Switch, and Indicator Lights Modulating Temperature Control System Designed to Maintain Discharge Temperature Set-Point  
Show parts
401M • Series 14 with RCS30 Control System (R-401M-S14-COR-60%/-15/47/120)  
  Maxitrol Series 14 Electronic Modulating Discharge Temperature Control with Remote Panel 40-80°F Discharge Temperature Set-Point Discharge Temperature Set-Point Mounted on Remote Panel Discharge Sensor Mounted in Blower Discharge RCS30 Re-Circulating Heater Control System Minimum Outside Temperature = -15°F, Maximum Discharge Temperature = 120°F Minimum Return Temperature = 47°F, Maximum Return Air % = 60% Controls Recirculating and Outdoor Air Dampers Remote Panel Includes Summer/Off/Winter Switch, and Indicator Lights Modulating Temperature Control System Designed to Maintain Discharge Temperature Set-Point  
Show parts
401M • Series 14 with RCS35 Control System (R-401M-S14-COR-80%/0/52/90)  
  Maxitrol Series 14 Electronic Modulating Discharge Temperature Control with Remote Panel 40-80°F Discharge Temperature Set-Point Discharge Temperature Set-Point Mounted on Remote Panel Discharge Sensor Mounted in Blower Discharge RCS35 Re-Circulating Heater Control System Minimum Outside Temperature = -0°F, Maximum Discharge Temperature = 90°F Minimum Return Temperature = 52°F, Maximum Return Air % = 80% Controls Recirculating and Outdoor Air Dampers Remote Panel Includes Summer/Off/Winter Switch, and Indicator Lights Modulating Temperature Control System Designed to Maintain Discharge Temperature Set-Point  
Show parts
401M • Series 14 with RCS40 Control System (R-401M-S14-COR-50%/0/35/140)  
  Maxitrol Series 14 Electronic Modulating Discharge Temperature Control with Remote Panel 40-80°F Discharge Temperature Set-Point Discharge Temperature Set-Point Mounted on Remote Panel Discharge Sensor Mounted in Blower Discharge RCS40 Re-Circulating Heater Control System Minimum Outside Temperature = -0°F, Maximum Discharge Temperature = 140°F Minimum Return Temperature = 35°F, Maximum Return Air % = 50% Controls Recirculating and Outdoor Air Dampers Remote Panel Includes Summer/Off/Winter Switch, and Indicator Lights Modulating Temperature Control System Designed to Maintain Discharge Temperature Set-Point  
Show parts
402M • Series 14 with RCS10 Space Heating Control System (R-402M-S14-COR-50%/-30/25/120)  
  Maxitrol Series 14 Electronic Modulating Discharge Temperature Control with Remote Panel and Room Override Thermostat 40-80°F Space Temperature Set-Point Mounted on Remote Panel 40°F Room Overide Mounted on Separate Remote Panel Discharge Set-Point Mounted on Remote Panel Discharge Sensor Mounted in Blower Discharge RCS10 Re-Circulating Heater Control System Minimum Outside Temperature = -30°F, Maximum Discharge Temperature = 120°F Minimum Return Temperature = 25°F, Maximum Return Air % = 50% Controls Recirculating and Outdoor Air Dampers Remote Panel Includes Summer/Off/Winter Switch and Indicator Lights Modulating Temperature Control System Designed to Maintain Discharge Temperature Set-Point  
Show parts
402M • Series 14 with RCS15 Space Heating Control System (R-402M-S14-COR-80%/-25/58/90)  
  Maxitrol Series 14 Electronic Modulating Discharge Temperature Control with Remote Panel and Room Override Thermostat 40-80°F Space Temperature Set-Point Mounted on Remote Panel 40°F Room Overide Mounted on Separate Remote Panel Discharge Set-Point Mounted on Remote Panel Discharge Sensor Mounted in Blower Discharge RCS15 Re-Circulating Heater Control System Minimum Outside Temperature = -25°F, Maximum Discharge Temperature = 90°F Minimum Return Temperature = 58°F, Maximum Return Air % = 80% Controls Recirculating and Outdoor Air Dampers Remote Panel Includes Summer/Off/Winter Switch and Indicator Lights Modulating Temperature Control System Designed to Maintain Discharge Temperature Set-Point  
Show parts
402M • Series 14 with RCS20 Space Heating Control System (R-402M-S14-COR-60%/-25/54/120)  
  Maxitrol Series 14 Electronic Modulating Discharge Temperature Control with Remote Panel and Room Override Thermostat 40-80°F Space Temperature Set-Point Mounted on Remote Panel 40°F Room Overide Mounted on Separate Remote Panel Discharge Set-Point Mounted on Remote Panel Discharge Sensor Mounted in Blower Discharge RCS20 Re-Circulating Heater Control System Minimum Outside Temperature = -25°F, Maximum Discharge Temperature = 120°F Minimum Return Temperature = 54°F, Maximum Return Air % = 60% Controls Recirculating and Outdoor Air Dampers Remote Panel Includes Summer/Off/Winter Switch and Indicator Lights Modulating Temperature Control System Designed to Maintain Discharge Temperature Set-Point  
Show parts
402M • Series 14 with RCS25 Space Heating Control System (R-402M-S14-COR-50%/-20/55/140)  
  Maxitrol Series 14 Electronic Modulating Discharge Temperature Control with Remote Panel and Room Override Thermostat 40-80°F Space Temperature Set-Point Mounted on Remote Panel 40°F Room Overide Mounted on Separate Remote Panel Discharge Set-Point Mounted on Remote Panel Discharge Sensor Mounted in Blower Discharge RCS25 Re-Circulating Heater Control System Minimum Outside Temperature = -20°F, Maximum Discharge Temperature = 140°F Minimum Return Temperature = 55°F, Maximum Return Air % = 50% Controls Recirculating and Outdoor Air Dampers Remote Panel Includes Summer/Off/Winter Switch and Indicator Lights Modulating Temperature Control System Designed to Maintain Discharge Temperature Set-Point  
Show parts
402M • Series 14 with RCS30 Space Heating Control System (R-402M-S14-COR-60%/-15/47/120)  
  Maxitrol Series 14 Electronic Modulating Discharge Temperature Control with Remote Panel and Room Override Thermostat 40-80°F Space Temperature Set-Point Mounted on Remote Panel 40°F Room Overide Mounted on Separate Remote Panel Discharge Set-Point Mounted on Remote Panel Discharge Sensor Mounted in Blower Discharge RCS30 Re-Circulating Heater Control System Minimum Outside Temperature = -15°F, Maximum Discharge Temperature = 120°F Minimum Return Temperature = 47°F, Maximum Return Air % = 60% Controls Recirculating and Outdoor Air Dampers Remote Panel Includes Summer/Off/Winter Switch and Indicator Lights Modulating Temperature Control System Designed to Maintain Discharge Temperature Set-Point  
Show parts
402M • Series 14 with RCS35 Space Heating Control System (R-402M-S14-COR-80%/0/52/90)  
  Maxitrol Series 14 Electronic Modulating Discharge Temperature Control with Remote Panel and Room Override Thermostat 40-80°F Space Temperature Set-Point Mounted on Remote Panel 40°F Room Overide Mounted on Separate Remote Panel Discharge Set-Point Mounted on Remote Panel Discharge Sensor Mounted in Blower Discharge RCS35 Re-Circulating Heater Control System Minimum Outside Temperature = -0°F, Maximum Discharge Temperature = 90°F Minimum Return Temperature = 52°F, Maximum Return Air % = 80% Controls Recirculating and Outdoor Air Dampers Remote Panel Includes Summer/Off/Winter Switch and Indicator Lights Modulating Temperature Control System Designed to Maintain Discharge Temperature Set-Point  
Show parts
402M • Series 14 with RCS40 Space Heating Control System (R-402M-S14-COR-50%/0/35/140)  
  Maxitrol Series 14 Electronic Modulating Discharge Temperature Control with Remote Panel and Room Override Thermostat 40-80°F Space Temperature Set-Point Mounted on Remote Panel 40°F Room Overide Mounted on Separate Remote Panel Discharge Set-Point Mounted on Remote Panel Discharge Sensor Mounted in Blower Discharge RCS40 Re-Circulating Heater Control System Minimum Outside Temperature = -0°F, Maximum Discharge Temperature = 140°F Minimum Return Temperature = 35°F, Maximum Return Air % = 50% Controls Recirculating and Outdoor Air Dampers Remote Panel Includes Summer/Off/Winter Switch and Indicator Lights Modulating Temperature Control System Designed to Maintain Discharge Temperature Set-Point  
Show parts
403M • Series 44 with RCS05 Space Heating Control System (R-403M-S44-COR-60%/-30/7/90)  
  Maxitrol Series 44 Electronic Modulating Space Temperature Control with Remote Panel 55-90°F Range Modulating Space Slectrastat Mounted on Remote Panel Discharge Sensor Mounted in Blower Discharge Minimum Discharge Set-Point 40-80°F, Factory Set at 60°F Maximum Discharge Set-Point 80-140°F, Factory Set at 90°F RCS5 Re-Circulating Heater Control System Minimum Outside Temperature = -30°F, Maximum Discharge Temperature = 90°F Minimum Return Temperature = 7°F, Maximum Return Air % = 60% Controls Recirculating and Outdoor Air Dampers Remote Panel Includes Summer/Off/Winter Switch, Selectrastat, and Indicator Lights Modulating Temperature Control System Designed to Maintain Space Temperature Set-Point  
Show parts
403M • Series 44 with RCS10 Space Heating Control System (R-403M-S44-COR-50%/-30/25/120)  
  Maxitrol Series 44 Electronic Modulating Space Temperature Control with Remote Panel 55-90°F Range Modulating Space Slectrastat Mounted on Remote Panel Discharge Sensor Mounted in Blower Discharge Minimum Discharge Set-Point 40-80°F. Factory Set at 60°F Maximum Discharge Set-Point 80-140°F. Factory Set at 120°F RCS10 Re-Circulating Heater Control System Minimum Outside Temperature = -30°F, Maximum Discharge Temperature = 120°F Minimum Return Temperature = 25°F, Maximum Return Air % = 50% Controls Recirculating and Outdoor Air Dampers Remote Panel Includes Summer/Off/Winter Switch, Selectrastat, and Indicator Lights Modulating Temperature Control System Designed to Maintain Space Temperature Set-Point  
Show parts
403M • Series 44 with RCS15 Space Heating Control System (R-403M-S44-COR-80%/-25/58/90)  
  Maxitrol Series 44 Electronic Modulating Space Temperature Control with Remote Panel 55-90°F Range Modulating Space Slectrastat Mounted on Remote Panel Discharge Sensor Mounted in Blower Discharge Minimum Discharge Set-Point 40-80°F, Factory Set at 60°F Maximum Discharge Set-Point 80-140°F, Factory Set at 90°F RCS15 Re-Circulating Heater Control System Minimum Outside Temperature = -25°F, Maximum Discharge Temperature = 90°F Minimum Return Temperature = 58°F, Maximum Return Air % = 80% Controls Recirculating and Outdoor Air Dampers Remote Panel Includes Summer/Off/Winter Switch, Selectrastat, and Indicator Lights Modulating Temperature Control System Designed to Maintain Space Temperature Set-Point  
Show parts
403M • Series 44 with RCS15 Space Heating Control System • Remote Sensor (R-403M-S44-COR-80%/-25/58/90-RS)  
  Maxitrol Series 44 Electronic Modulating Space Temperature Control with Remote Panel 55-90°F Range Modulating Space Set-Point Mounted on Remote Panel With Remote Temperature Sensor Discharge Sensor Mounted in Blower Discharge Minimum Discharge Set-Point 40-80°F, Factory Set at 60°F Maximum Discharge Set-Point 80-140°F, Factory Set at 90°F RCS15 Re-Circulating Heater Control System Minimum Outside Temperature = -25°F, Maximum Discharge Temperature = 90°F Minimum Return Temperature = 58°F, Maximum Return Air % = 80% Controls Recirculating and Outdoor Air Dampers Remote Panel Includes Summer/Off/Winter Switch, Set Point, and Indicator Lights Modulating Temperature Control System Designed to Maintain Space Temperature Set-Point  
Show parts
403M • Series 44 with RCS20 Space Heating Control System (R-403M-S44-COR-60%/-25/54/120)  
  Maxitrol Series 44 Electronic Modulating Space Temperature Control with Remote Panel 55-90°F Range Modulating Space Slectrastat Mounted on Remote Panel Discharge Sensor Mounted in Blower Discharge Minimum Discharge Set-Point 40-80°F, Factory Set at 60°F Maximum Discharge Set-Point 80-140°F, Factory Set at 120°F RCS20 Re-Circulating Heater Control System Minimum Outside Temperature = -25°F, Maximum Discharge Temperature = 120°F Minimum Return Temperature = 54°F, Maximum Return Air % = 60% Controls Recirculating and Outdoor Air Dampers Remote Panel Includes Summer/Off/Winter Switch, Selectrastat, and Indicator Lights Modulating Temperature Control System Designed to Maintain Space Temperature Set-Point  
Show parts
403M • Series 44 with RCS25 Space Heating Control System (R-403M-S44-COR-50%/-20/55/140)  
  Maxitrol Series 44 Electronic Modulating Space Temperature Control with Remote Panel 55-90°F Range Modulating Space Slectrastat Mounted on Remote Panel Discharge Sensor Mounted in Blower Discharge Minimum Discharge Set-Point 40-80°F, Factory Set at 60°F Maximum Discharge Set-Point 80-140°F, Factory Set at 120°F RCS25 Re-Circulating Heater Control System Minimum Outside Temperature = -20°F, Maximum Discharge Temperature = 140°F Minimum Return Temperature = 55°F, Maximum Return Air % = 50% Controls Recirculating and Outdoor Air Dampers Remote Panel Includes Summer/Off/Winter Switch, Selectrastat, and Indicator Lights Modulating Temperature Control System Designed to Maintain Space Temperature Set-Point  
Show parts
403M • Series 44 with RCS30 Space Heating Control System (R-403M-S44-COR-60%/-15/47/120)  
  Maxitrol Series 44 Electronic Modulating Space Temperature Control with Remote Panel 55-90°F Range Modulating Space Slectrastat Mounted on Remote Panel Discharge Sensor Mounted in Blower Discharge Minimum Discharge Set-Point 40-80°F, Factory Set at 60°F Maximum Discharge Set-Point 80-140°F, Factory Set at 120°F RCS30 Re-Circulating Heater Control System Minimum Outside Temperature = -15°F, Maximum Discharge Temperature = 120°F Minimum Return Temperature = 47°F, Maximum Return Air % = 60% Controls Recirculating and Outdoor Air Dampers Remote Panel Includes Summer/Off/Winter Switch, Selectrastat, and Indicator Lights Modulating Temperature Control System Designed to Maintain Space Temperature Set-Point  
Show parts
403M • Series 44 with RCS35 Space Heating Control System (R-403M-S44-COR-80%/0/52/90)  
  Maxitrol Series 44 Electronic Modulating Space Temperature Control with Remote Panel 55-90°F Range Modulating Space Slectrastat Mounted on Remote Panel Discharge Sensor Mounted in Blower Discharge Minimum Discharge Set-Point 40-80°F, Factory Set at 60°F Maximum Discharge Set-Point 80-140°F, Factory Set at 90°F RCS35 Re-Circulating Heater Control System Minimum Outside Temperature = -0°F, Maximum Discharge Temperature = 90°F Minimum Return Temperature = 52°F, Maximum Return Air % = 80% Controls Recirculating and Outdoor Air Dampers Remote Panel Includes Summer/Off/Winter Switch, Selectrastat, and Indicator Lights Modulating Temperature Control System Designed to Maintain Space Temperature Set-Point  
Show parts
403M • Series 44 with RCS40 Space Heating Control System (R-403M-S44-COR-50%/0/35/140)  
  Maxitrol Series 44 Electronic Modulating Space Temperature Control with Remote Panel 55-90°F Range Modulating Space Slectrastat Mounted on Remote Panel Discharge Sensor Mounted in Blower Discharge Minimum Discharge Set-Point 40-80°F, Factory Set at 60°F Maximum Discharge Set-Point 80-140°F, Factory Set at 120°F RCS40 Re-Circulating Heater Control System Minimum Outside Temperature = -0°F, Maximum Discharge Temperature = 140°F Minimum Return Temperature = 35°F, Maximum Return Air % = 50% Controls Recirculating and Outdoor Air Dampers Remote Panel Includes Summer/Off/Winter Switch, Selectrastat, and Indicator Lights Modulating Temperature Control System Designed to Maintain Space Temperature Set-Point  
Show parts
50-90°F Industrial Recirculating Space Temp Control • Heating Activation Based On Either Intake or Space Set Point • Manual Blower Mode. Use with MUA. (R-RCS-SPACE-EITHER-50-90-MANUAL-NEW)  
  50-90°F Range Modulating Space Recirculating Temperature Control Unit Maximum Discharge 120°F Space HMI Shipped Loose for Room Mounting Modulating Temperature Control System Designed to Maintain Space Temperature Set-Point Heating Activation Based On Either Intake or Space Set Point Manual Blower Mode  
Show parts
Building Management Signal RCS15 • 0 to 10VDC or 4-20mA Signal Conditioner • Blower/Heat/Cooling Relays (R-BMS-COR-80%/-25/58/90)  
  Building Management System That Receives a 0-10VDC or 4-20mA Signal for Heat Modulation Blower Start/Heat Start/Cooling Start 24VAC Relays Included RCS15 Re-Circulating Heater Control System Minimum Outside Temperature = -25°F, Maximum Discharge Temperature = 90°F Minimum Return Temperature = 58°F, Maximum Return Air % = 80% Controls Recirculating and Outdoor Air Dampers Modulating Temperature Control System  
Show parts
Building Management Signal RCS30 • 0 to 10VDC or 4-20mA Signal Conditioner • Blower/Heat/Cooling Relays (R-BMS-COR-60%/-15/47/120)  
  Building Management System That Receives a 0-10VDC or 4-20mA Signal for Heat Modulation Blower Start/Heat Start/Cooling Start 24VAC Relays Included RCS30 Re-Circulating Heater Control System Minimum Outside Temperature = -15°F, Maximum Discharge Temperature = 120°F Minimum Return Temperature = 47°F, Maximum Return Air % = 60% Controls Recirculating and Outdoor Air Dampers Modulating Temperature Control System  
Show parts
Building Management Signal RCS35 • 0 to 10VDC or 4-20mA Signal Conditioner • Blower/Heat.Cooling Relays (R-BMS-COR-80%/0/52/90)  
  Building Management System That Receives a 0-10VDC or 4-20mA Signal for Heat Modulation Blower Start/Heat Start/Cooling Start 24VAC Relays Included RCS35 Re-Circulating Heater Control System Minimum Outside Temperature = -0°F, Maximum Discharge Temperature = 90°F Minimum Return Temperature = 52°F, Maximum Return Air % = 80% Controls Recirculating and Outdoor Air Dampers Modulating Temperature Control System  
Show parts
Maxitrol "M" Series Programmable Controller with RCS15 System • High Temp Components Ship Loose (R-M Series RCS15 No Remotes)  
  Maxitrol "M" Series Programmable Controller with RCS15 System.  
Show parts
Paint Booth • Maxitrol "M" Series Programmable Control • Cure Only • RCS • High Temp (R-PB-C-1-RCS-M Series)  
  Maxitrol "M" Series Programmable Controller. Cure Only Re-circulating Heater Controls Controls 1 or 2, Single Speed Booth Exhasut Fans "On" Push Button "M" Series Control Start Delay Timer Power On Light Blower On Light Burner On Light Flame Failure Light Fire System Interlocks Cure Timer Cure Light Cool Down Cycle with Light Lights Out During and After Cure Solenoid Lockout during Cure  
Show parts
Paint Booth • Maxitrol "M" Series Programmable Control • Spray/Cure • Single Speed EFs • RCS • High Temp (R-PB-SC-1-RCS-M Series)  
  Maxitrol "M" Series Programmable Controller. Spray/Cure Re-Circulating Heater Controls Controls 1 or 2, 1-Speed Booth Exhasut Fans "On" Push Button "M" Series Control Start Delay Timer Power On Light Blower On Light Burner On Light Flame Failure Light Fire System Interlocks Solenoid Interlocks Spray Light Cure Timer Cure Light Cool Down Cycle with Light Solenoid Lockout during Cure  
Show parts
Signal Conditioner with RCS30 that uses 4-20mA or 0-10v control. (R-SC-COR-60%/-15/47/120)  
  Signal Conditioner with RCS35 that uses 4-20mA or 0-10v control with Remote Panel. Remote Panel Includes Summer/Off/Winter Switch and Indicator Lights RCS30 Re-Circulating Heater Control System Minimum Outside Temperature = -15°F, Maximum Discharge Temperature = 120°F Minimum Return Temperature = 47°F, Maximum Return Air % = 60%  
Show parts
XGFSM • 401M • Series 14 with RCS20 Space Heating Control System (R-GFS-401M-S14-COR-60%/-25/54/120)  
  Maxitrol Series 14 Electronic Modulating Discharge Temperature Control 40-80°F Discharge Temperature Set-Point Discharge Sensor Mounted in Blower Discharge Remote Panel by GFS RCS20 Re-Circulating Heater Control System Minimum Outside Temperature = -25°F, Maximum Discharge Temperature = 120°F Minimum Return Temperature = 54°F, Maximum Return Air % = 60%  
Show parts
XGFSM • 401M • Series 14 with RCS30 Space Heating Control System (R-GFS-401M-S14-COR-60%/-15/47/120)  
  Maxitrol Series 14 Electronic Modulating Discharge Temperature Control 40-80°F Discharge Temperature Set-Point Discharge Sensor Mounted in Blower Discharge Remote Panel by GFS RCS30 Re-Circulating Heater Control System Minimum Outside Temperature = -15°F, Maximum Discharge Temperature = 120°F Minimum Return Temperature = 47°F, Maximum Return Air % = 60%  
Show parts
XGFSM • 401M PLC Series 14 Specialized Control System (R-GFSM-401M-S14-40-80-PLC)  
  401M-Maxitrol Series 14 Electronic Modulating Discharge Temperature Control Discharge Sensor Mounted in Blower Discharge Specialized PLC Control w/ N.O. Contacts Remote Panels & Controls By Others  
Show parts
XGFSM • 401M PLC Series 14 Specialized Control System with RCS15 Space Heating Control System (R-GFSM-401M-S14-COR-80%/-25/58/90-PLC)  
  401M-Maxitrol Series 14 Electronic Modulating Discharge Temperature Control Single Range - 40°F to 80°F Discharge Sensor Mounted in Blower Discharge Specialized PLC Control w/ N.O. Contacts Remote Panels & Controls By Others RCS15 Re-Circulating Heater Control System Minimum Outside Temperature = -25°F, Maximum Discharge Temperature = 90°F Minimum Return Temperature = 58°F, Maximum Return Air % = 80%  
Show parts
XGFSM • 7EC PLC Signal Conditioner • High Temp (R-GFSM-SC-PLC)  
  7EC Signal Conditioner that uses 4-20mA or 0-10v control. Specialized PLC Control w/ N.O. Contacts Remote Panels & Controls By Others  
Show parts
XGFSM • 7EC Signal Conditioner • High Temp (R-GFSM-SC)  
  7EC Signal Conditioner that uses 4-20mA or 0-10v control. Remote Panels & Controls By Others  
Show parts
XGFSM • Maxitrol "M" Series Programmable Control • High Temp • RCS15 (R-GFSM-M Series-COR-80%/-25/50/90)  
  Maxitrol "M" Series Programmable Controller. Remote Panels & Controls By Others  
Show parts
Gas Manifold Parts
Click on a part # to order that part.
Part Per Unit List
Industrial Gas Manifold - 14 in. w.c. - 1 lb., FIA/IRI Insurance Requirement, BV250-1010  
1925000 - 2199999 BTU
Show parts
2200000 - 2474999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., FIA/IRI Insurance Requirement, BV250-1212  
2475000 - 2749999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., FIA/IRI Insurance Requirement, BV250-1616  
2750000 - 4124999 BTU
Show parts
4125000 - 7974999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., FIA/IRI Insurance Requirement, BV250-2020  
7975000 - 9624999 BTU
Show parts
9625000 - 11274999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., FIA/IRI Insurance Requirement, BV250-2424  
11275000 - 12924999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., FIA/IRI Insurance Requirement, BV250-66  
0 - 399999 BTU
Show parts
400000 - 549999 BTU
Show parts
550000 - 824999 BTU
Show parts
825000 - 999999 BTU
Show parts
1000000 - 1374999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., FIA/IRI Insurance Requirement, BV250-88  
1375000 - 1649999 BTU
Show parts
1650000 - 1924999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., FM Insurance Requirement, BV250-1010  
1925000 - 2199999 BTU
Show parts
2200000 - 2474999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., FM Insurance Requirement, BV250-1212  
2475000 - 2499999 BTU
Show parts
2500000 - 2749999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., FM Insurance Requirement, BV250-1616  
2750000 - 4124999 BTU
Show parts
4125000 - 5774999 BTU
Show parts
5775000 - 6324999 BTU
Show parts
6325000 - 7974999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., FM Insurance Requirement, BV250-2020  
7975000 - 8524999 BTU
Show parts
8525000 - 9624999 BTU
Show parts
9625000 - 11274999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., FM Insurance Requirement, BV250-2424  
11275000 - 12374999 BTU
Show parts
12375000 - 12924999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., FM Insurance Requirement, BV250-66  
0 - 824999 BTU
Show parts
825000 - 1374999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., FM Insurance Requirement, BV250-88  
1375000 - 1649999 BTU
Show parts
1650000 - 1924999 BTU
Show parts
Ind Gas Man - 14 in. w.c. - 1 lb., FM Insurance Requirement with Proof of Closure, BV250-1010  
1925000 - 2199999 BTU
Show parts
2200000 - 2474999 BTU
Show parts
Ind Gas Man - 14 in. w.c. - 1 lb., FM Insurance Requirement with Proof of Closure, BV250-1212  
2475000 - 2499999 BTU
Show parts
2500000 - 2749999 BTU
Show parts
Ind Gas Man - 14 in. w.c. - 1 lb., FM Insurance Requirement with Proof of Closure, BV250-1616  
2750000 - 4124999 BTU
Show parts
4125000 - 5774999 BTU
Show parts
5775000 - 6324999 BTU
Show parts
6325000 - 7974999 BTU
Show parts
Ind Gas Man - 14 in. w.c. - 1 lb., FM Insurance Requirement with Proof of Closure, BV250-2020  
7975000 - 8524999 BTU
Show parts
8525000 - 9624999 BTU
Show parts
9625000 - 11274999 BTU
Show parts
Ind Gas Man - 14 in. w.c. - 1 lb., FM Insurance Requirement with Proof of Closure, BV250-2424  
11275000 - 12374999 BTU
Show parts
12375000 - 12924999 BTU
Show parts
Ind Gas Man - 14 in. w.c. - 1 lb., FM Insurance Requirement with Proof of Closure, BV250-66  
0 - 824999 BTU
Show parts
825000 - 1374999 BTU
Show parts
Ind Gas Man - 14 in. w.c. - 1 lb., FM Insurance Requirement with Proof of Closure, BV250-88  
1375000 - 1649999 BTU
Show parts
1650000 - 1924999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., No Insurance Requirement (ANSI), BV250-1010  
1925000 - 2199999 BTU
Show parts
2200000 - 2474999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., No Insurance Requirement (ANSI), BV250-1212  
2475000 - 2749999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., No Insurance Requirement (ANSI), BV250-1616  
2750000 - 4124999 BTU
Show parts
4125000 - 6874999 BTU
Show parts
6875000 - 7974999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., No Insurance Requirement (ANSI), BV250-2020  
7975000 - 8524999 BTU
Show parts
8525000 - 9624999 BTU
Show parts
9625000 - 11274999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., No Insurance Requirement (ANSI), BV250-2424  
11275000 - 12924999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., No Insurance Requirement (ANSI), BV250-66  
0 - 549999 BTU
Show parts
550000 - 824999 BTU
Show parts
825000 - 1374999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., No Insurance Requirement (ANSI), BV250-88  
1375000 - 1649999 BTU
Show parts
1650000 - 1924999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., No Insurance Requirement with Proof of Closure, BV250-1010  
1925000 - 2199999 BTU
Show parts
2200000 - 2474999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., No Insurance Requirement with Proof of Closure, BV250-1212  
2475000 - 2749999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., No Insurance Requirement with Proof of Closure, BV250-1616  
2750000 - 4124999 BTU
Show parts
4125000 - 6874999 BTU
Show parts
6875000 - 7974999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., No Insurance Requirement with Proof of Closure, BV250-2020  
7975000 - 8524999 BTU
Show parts
8525000 - 9624999 BTU
Show parts
9625000 - 11274999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., No Insurance Requirement with Proof of Closure, BV250-2424  
11275000 - 12374999 BTU
Show parts
12375000 - 12924999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., No Insurance Requirement with Proof of Closure, BV250-66  
0 - 549999 BTU
Show parts
550000 - 824999 BTU
Show parts
825000 - 1374999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., No Insurance Requirement with Proof of Closure, BV250-88  
1375000 - 1649999 BTU
Show parts
1650000 - 1924999 BTU
Show parts
Industrial Gas Manifold - 1 lb. - 5 lb., FIA/IRI Insurance Requirement, BV250-1010  
2750000 - 3574999 BTU
Show parts
Industrial Gas Manifold - 1 lb. - 5 lb., FIA/IRI Insurance Requirement, BV250-1212  
3575000 - 4124999 BTU
Show parts
Industrial Gas Manifold - 1 lb. - 5 lb., FIA/IRI Insurance Requirement, BV250-1616  
4125000 - 6874999 BTU
Show parts
6875000 - 9624999 BTU
Show parts
9625000 - 10174999 BTU
Show parts
10175000 - 11824999 BTU
Show parts
Industrial Gas Manifold - 1 lb. - 5 lb., FIA/IRI Insurance Requirement, BV250-2020  
11825000 - 12924999 BTU
Show parts
Industrial Gas Manifold - 1 lb. - 5 lb., FIA/IRI Insurance Requirement, BV250-66  
0 - 399999 BTU
Show parts
400000 - 824999 BTU
Show parts
825000 - 999999 BTU
Show parts
1000000 - 1374999 BTU
Show parts
Industrial Gas Manifold - 1 lb. - 5 lb., FIA/IRI Insurance Requirement, BV250-88  
1375000 - 1649999 BTU
Show parts
1650000 - 2199999 BTU
Show parts
2200000 - 2749999 BTU
Show parts
Industrial Gas Manifold - 1 lb. - 5 lb., FM Insurance Requirement, BV250-1010  
2750000 - 3574999 BTU
Show parts
Industrial Gas Manifold - 1 lb. - 5 lb., FM Insurance Requirement, BV250-1212  
3575000 - 4124999 BTU
Show parts
Industrial Gas Manifold - 1 lb. - 5 lb., FM Insurance Requirement, BV250-1616  
4125000 - 4674999 BTU
Show parts
4675000 - 5699000 BTU
Show parts
Industrial Gas Manifold - 1 lb. - 5 lb., FM Insurance Requirement, BV250-2020  
11825000 - 12374999 BTU
Show parts
12375000 - 12924999 BTU
Show parts
Industrial Gas Manifold - 1 lb. - 5 lb., FM Insurance Requirement, BV250-66  
0 - 824999 BTU
Show parts
825000 - 999999 BTU
Show parts
1000000 - 1374999 BTU
Show parts
Industrial Gas Manifold - 1 lb. - 5 lb., FM Insurance Requirement, BV250-88  
1375000 - 1649999 BTU
Show parts
1650000 - 2199999 BTU
Show parts
2200000 - 2499999 BTU
Show parts
2500000 - 2749999 BTU
Show parts
Industrial Gas Manifold - 1 lb. - 5 lb., FM Insurance Requirement with Proof of Closure, BV250-1010  
2750000 - 3574999 BTU
Show parts
Industrial Gas Manifold - 1 lb. - 5 lb., FM Insurance Requirement with Proof of Closure, BV250-1212  
3575000 - 4124999 BTU
Show parts
Industrial Gas Manifold - 1 lb. - 5 lb., FM Insurance Requirement with Proof of Closure, BV250-1616  
4125000 - 4674999 BTU
Show parts
4675000 - 6874999 BTU
Show parts
6875000 - 9074999 BTU
Show parts
9075000 - 10174999 BTU
Show parts
10175000 - 11824999 BTU
Show parts
Industrial Gas Manifold - 1 lb. - 5 lb., FM Insurance Requirement with Proof of Closure, BV250-2020  
11825000 - 12374999 BTU
Show parts
12375000 - 12924999 BTU
Show parts