Rep Our Products

Are you interested in representing CaptiveAire and selling our products?
Please fill out the following form, and we will contact you soon.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

 
A2-E.734-G15 Parts
Motors, Pulleys, & Motor Specific Parts
Motor HP Phs Voltage FLA Shaft Frame Weight RPM Vendor
Lookup Part!  - .7518OT3E56-S48PP-50Hz 0.750 3 190/220-230/380/415 V 2.6/2.4-2.9/1.3/1.3 0.625" 56 29 lbs 1410 WEG
ODP (Open Drip Proof) Pulleys
Show parts
Lookup Part!  - .7518OT3E56-S48PP 0.750 3 208-220-230/380/460 V 2.5-2.3-2.3/1.3/1.1 0.625" 56 24 lbs 1735 WEG
ODP (Open Drip Proof) Pulleys
Show parts
Lookup Part!  - CK56HB02F01-60HZ 0.750 1 115/208-230 V 6/3.3-3 0.625" 56 34 lbs 1750 HSSA
ODP (Open Drip Proof) Pulleys
Show parts
Lookup Part!  - CK56HB02D01-60HZ 1.000 1 115/208-220-230 V 8.1/4.4-4.1-4 0.625" 56 39 lbs 1750 HSSA
ODP (Open Drip Proof) Pulleys
Show parts
Lookup Part!  - 00118OT3E56-S48PP 1.000 3 208-220-230/380/460 V 3.4-3.9-3.1/1.9/1.5 0.625" 56 26 lbs 1720 WEG
ODP (Open Drip Proof) Pulleys
Show parts
Lookup Part!  - 00158OT3E56-S48PP-50HZ 1.500 3 190/220/380/415 V 5.1/4.8/2.5/2.5 0.625" 56 31 lbs 1430 WEG
ODP (Open Drip Proof) Pulleys
Show parts
Lookup Part!  - 00158OT3E56-S48PP 1.500 3 208-220-230/380/460 V 4.6-4.2-4.2/2.4/2.1 0.625" 56 31 lbs 1710 WEG
ODP (Open Drip Proof) Pulleys
Show parts
Lookup Part!  - 00218OT3E56Z-S48PP-50HZ 1.500 3 190/220/380/415 V 6.5/5.7/3.2/3 0.875" 56HZ 40 lbs 1400 WEG
ODP (Open Drip Proof) Pulleys
Show parts
Lookup Part!  - CK56HB02C01-60HZ 1.500 1 115/208-230 V 12.2/6.7-6 0.625" 56 50 lbs 1750 HSSA
ODP (Open Drip Proof) Pulleys
Show parts
Lookup Part!  - B338 1.500 1 277 V 7.5 0.625" 56H 38 lbs 1725 Marathon
ODP (Open Drip Proof) Pulleys
Show parts
Lookup Part!  - CK56HB02B01-60HZ 2.000 1 115/208-230 V 16.5/9.5-8.1 0.875" 56HZ 58 lbs 1750 HSSA
ODP (Open Drip Proof) Pulleys
Show parts
Lookup Part!  - 00218OT3E56Z-S48PP 2.000 3 208-230/415/460 V 5.9-5.3/3/2.6 0.875" 56 40 lbs 1700 WEG
ODP (Open Drip Proof) Pulleys
Show parts
Lookup Part!  - 00318OT3E56Z-S48PP-50HZ 2.000 3 190/220/380/415 V 6.9/6.7/3.4/3.5 0.875" 56 55 lbs 1410 WEG
ODP (Open Drip Proof) Pulleys
Show parts
Lookup Part!  - 00318OS1C184T 3.000 1 208-230 V 18.6-17.5 1.125" 184T 73 lbs 1745 WEG
ODP (Open Drip Proof) Pulleys
Show parts
Lookup Part!  - 00518OS1C184T 5.000 1 208-230 V 27.1-24.6 1.125" 184T 99 lbs 1750 WEG
ODP (Open Drip Proof) Pulleys
Show parts
Lookup Part!  - DTP0014 1.000 3 208-230/460 V 3.1-2.8/1.4 0.875" 143 35 lbs 1750 Mimco/TECO
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
Lookup Part!  - 00118OT3H143T-S 1.000 3 575 V 1.2 0.875" 143T 34 lbs 1750 WEG
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
Lookup Part!  - 00158OT3H145T-S 1.500 3 575 V 1.6 0.875" 145T 42 lbs 1750 WEG
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
Lookup Part!  - DTP1/54 1.500 3 190/208-230/380/460 V 4.6/4.4-4/2.3/2 0.875" 145 46 lbs 1750 Mimco/TECO
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
Lookup Part!  - 00218OT3H145T-S 2.000 3 575 V 2.1 0.875" 145T 39 lbs 1750 WEG
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
Lookup Part!  - DTP0024 2.000 3 190/208-230/380/460 V 5.9/6.1-5.5/2.9/2.7 0.875" 145T 44 lbs 1740 Mimco/TECO
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
Lookup Part!  - DTP0034 3.000 3 208-230/380/415/460 V 9.5-8.6/5.2/4.8/4.3 1.125" 182T 69 lbs 1755 Mimco/TECO
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
Lookup Part!  - 00318OT3E56Z-48PP 3.000 3 208-230/380/460 V 8.7-7.9/4.8/3.9 0.875" 56 55 lbs 1730 WEG
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
Lookup Part!  - 00318OT3H182T-S 3.000 3 575 V 3 1.125" 182T 66 lbs 1750 WEG
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
Lookup Part!  - DHP0034 3.000 3 208-230/460 V 8.5-7.8/3.9 1.125" 182T 95 lbs 1750 Mimco/TECO
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
Lookup Part!  - 00518OT3H184T-S 5.000 3 575 V 5 1.125" 184T 80 lbs 1750 WEG
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
Lookup Part!  - DTP0054 5.000 3 190/200-208-230/380/400/415/460 V 17/15.6-15-13.6/8.5/7.7/7.5/6.8 1.125" 184T 77 lbs 1750 Mimco/TECO
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
Lookup Part!  - DTP0054-50 5.000 3 190/208-230/380/415 V 14.9/15-13.6/7.5/8.1 1.125" 182T 89 lbs 1435 Mimco/TECO
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
Lookup Part!  - H869L 0.750 3 208-230/460 V 2.4-2.4/1.2 0.625" 56 20 lbs 1800 Regal Beloit/A.O. Smith
TEFC (Totally Enclosed Fan Cooled) Pulleys
Show parts
Lookup Part!  - 131509 2.000 1 115/208-230 V 24.8/13-12.4 1.125" 182T 75 lbs 1740 Leeson/Rempfer & Assoc.
TEFC (Totally Enclosed Fan Cooled) Pulleys
Show parts
Lookup Part!  - GP0014 1.000 3 200-208-230/400/460 V 2.9-3-2.7/1.4/1.3 0.875" L143T 36 lbs 1800 Mimco/TECO
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
Lookup Part!  - 00118ET3H143T-W22 1.000 3 575 V 1.2 0.875" 143T 48 lbs 1750 WEG
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
Lookup Part!  - 00158ET3H145T-W22 1.500 3 575 V 1.6 0.875" 145T 53 lbs 1750 WEG
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
Lookup Part!  - GP1/54 1.500 3 190/200-208-230/380/400/460 V 4.3/4.3-4.5-4/2.1/2.1/2.1 0.875" 145T 40 lbs 1800 Mimco/TECO
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
Lookup Part!  - GP0024 2.000 3 190/200-208-230/380/400/460 V 6/5.9-5.7-5.2/3/2.9/2.6 0.875" 145T 40 lbs 1740 Mimco/TECO
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
Lookup Part!  - 00218ET3H145T-W22 2.000 3 575 V 2.2 0.875" 145T 54 lbs 1750 WEG
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
Lookup Part!  - 00318ET3H182T-W22 3.000 3 575 V 3.1 1.125" 182T 94 lbs 1750 WEG
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
Lookup Part!  - GP0034 3.000 3 190/208-230/380/400/460 V 9.8/9.4-8.5/4.9/4.6/4.3 1.125" 182T 60 lbs 1800 Mimco/TECO
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
Lookup Part!  - GP0054 5.000 3 190/200-208-230/380/400/460 V 15.6/14.9-14.5-13.1/7.8/7.4/6.6 1.125" 184T 82 lbs 1800 Mimco/TECO
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
Lookup Part!  - 00518ET3H184T-W22 5.000 3 575 V 5.1 1.125" 184T 104 lbs 1750 WEG
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts

The manufacturer reserves the right to use alternate motors from alternate vendors that meet the operating requirements of the fan but may have slightly different specifications.
Intakes & Intake Parts
Part
Lookup Part! CD-VB-I-02MDF-TA Celdek and V-Bank for Size # 2 Modular Heater with TA filters. For indoor installation. MERV 8 V-Bank Filters.
Show parts
Lookup Part! CD-VB-I-02MDF-TA-13 Celdek and V-Bank for Size # 2 Modular Heater with TA filters. For indoor installation. MERV 13 V-Bank Filters.
Show parts
Lookup Part! CD-VB-I-02MDF Celdek and V-Bank for Size # 2 Modular Heater. For indoor installation.
Show parts
Lookup Part! CD-VB-O-02M-HE Celdek and V-Bank for Size # 2 Modular Supply unit with HE filters. For outdoor installation. MERV 15 V-Bank Filters. Includes Screened Intake
Show parts
Lookup Part! CD-VB-O-02M-HE-IL Celdek and V-Bank for Size # 2 Modular Supply unit with HE filters. For outdoor installation. MERV 15 V-Bank Filters. Includes Intake Louver.
Show parts
Lookup Part! CD-VB-I-02M-HE Celdek and V-Bank for Size # 2 Modular Supply unit with HE filters. For indoor installation. MERV 15 V-Bank Filters.
Show parts
Lookup Part! CD-VB-O-02M-HEPA Celdek and V-Bank for Size # 2 Modular Supply unit with HEPA filters. For outdoor installation. Includes Screened Intake
Show parts
Lookup Part! CD-VB-O-02M-HEPA-IL Celdek and V-Bank for Size # 2 Modular Supply unit with HEPA filters. For outdoor installation. Includes Intake Louver.
Show parts
Lookup Part! CD-VB-I-02M-HEPA Celdek and V-Bank for Size # 2 Modular Supply unit with HEPA filters. For indoor installation.
Show parts
Lookup Part! CD-VB-O-02M-TA Celdek and V-Bank for Size # 2 Modular Supply unit with TA filters. For outdoor installation. MERV 8 V-Bank Filters. Includes Screened Intake
Show parts
Lookup Part! CD-VB-O-02M-TA-IL Celdek and V-Bank for Size # 2 Modular Supply unit with TA filters. For outdoor installation. MERV 8 V-Bank Filters. Includes Intake Louver.
Show parts
Lookup Part! CD-VB-O-02M-TA-13 Celdek and V-Bank for Size # 2 Modular Supply unit with TA filters. For outdoor installation. MERV 13 V-Bank Filters. Includes Screened Intake
Show parts
Lookup Part! CD-VB-O-02M Celdek and V-Bank for Size # 2 Modular Supply unit. For outdoor installation. Includes Screened Intake
Show parts
Lookup Part! CD-VB-O-02M-IL Celdek and V-Bank for Size # 2 Modular Supply unit. For outdoor installation. Includes Intake Louver.
Show parts
Lookup Part! CD-I A2DF Celdek Evaporative Cooler for Size # 2 Modular Heater. 36.75" Wide X 32.125" Long X 36.688" High. For indoor installation. Min. water pressure for optimal performance is 30 PSI. Max. water pressure should not exceed 50 PSI. Use with water softener recommended.
Show parts
Lookup Part! CD-O A2DF Celdek Evaporative Cooler for Size # 2 Modular Heater. 36.75" Wide X 62.438" Long X 36.688" High. Includes screened intake. For outdoor installation. Use with water softener recommended.
Show parts
Lookup Part! CD-O A2DF-IH Celdek Evaporative Cooler for Size # 2 Modular Heater. 36.75" Wide X 85.813" Long X 36.688" High. Includes intake hood with filters. For outdoor installation. Use with water softener recommended.
Show parts
Lookup Part! CD-O A2DF-NF Celdek Evaporative Cooler for Size # 2 Modular Heater. 36.75" Wide X 85.813" Long X 36.688" High. Includes intake hood without filters. For outdoor installation. Use with water softener recommended.
Show parts
Lookup Part! CD-O A2-IL Celdek Evaporative Cooler for Size # 2 Modular Un-tempered Supply Air Unit. ~36.75" Wide X 62.438" Long X 36.688" High. Includes intake louver. For outdoor installation. Use with water softener recommended.
Show parts
Lookup Part! SI-2 Screen Intake for Size 2 Commercial Fans.
Show parts
Lookup Part! CD-O A3DF-2 Size # 3 Celdek Evaporative Cooler for Size # 2 Modular Heater. 40.75" Wide x 72.313" Long x 43.375" High. Includes screened intake. For outdoor installation. Use with water softener recommended.
Show parts
Lookup Part! CD-O A3DF-IH-2 Size # 3 Celdek Evaporative Cooler for Size # 2 Modular Make-Up Air Heater. 40.75" Wide x 83.75" Long x 43.375" High. Includes intake hood with filters. For outdoor installation. Use with water softener recommended.
Show parts
Lookup Part! CD-O A3DF-NF-2 Size # 3 Celdek Evaporative Cooler for Size # 2 Modular Make-Up Air Heater. 40.75" Wide x 83.75" Long x 43.375" High. Includes intake hood without filters. For outdoor installation. Use with water softener recommended.
Show parts
Lookup Part! CD-O A3-2-IL Size # 3 Celdek Evaporative Cooler for Size # 2 Modular Un-tempered Supply Air Unit. 40.75" Wide x 72.313" Long x 43.375" High. Includes intake louver. For outdoor installation. Use with water softener recommended.
Show parts
Lookup Part! CD-LPD-VB-O-03-2M-IL Size 3 Celdek and V-Bank for Size # 2 Modular Supply unit. For outdoor installation. Includes Intake Louver.
Show parts
Lookup Part! CD-I A3DF-2 Size 3 Celdek Evaporative Cooler for Size # 2 Modular Make-Up Air Heater. 40.75" Wide x 38.125" Long x 43.375" High. For indoor installation. Min. water pressure for optimal performance is 30 PSI. Max. water pressure should not exceed 50 PSI. Use with water softener recommended.
Show parts
Lookup Part! CD-LPD-VB-I-03-2M Size 3 LPD Celdek and V-Bank for Size # 2 Modular Supply unit. For indoor installation.
Show parts
Lookup Part! CD-LPD-VB-I-03-2M-TA Size 3 LPD Celdek and V-Bank for Size # 2 Modular Supply unit. For indoor installation.
Show parts
Lookup Part! CD-LPD-VB-I-03-2M-TA-13 Size 3 LPD Celdek and V-Bank for Size # 2 Modular Supply unit. For indoor installation.
Show parts
Lookup Part! CD-LPD-VB-I-03-2M-HE Size 3 LPD Celdek and V-Bank for Size # 2 Modular Supply unit. For indoor installation.
Show parts
Lookup Part! CD-LPD-VB-I-03-2M-HEPA Size 3 LPD Celdek and V-Bank for Size # 2 Modular Supply unit. For indoor installation.
Show parts
Lookup Part! CD-LPD-VB-O-03-2M-HEPA Size 3 LPD Celdek and V-Bank for Size # 2 Modular Supply unit. For outdoor installation. Includes Screened Intake
Show parts
Lookup Part! CD-LPD-VB-O-03-2M-HE Size 3 LPD Celdek and V-Bank for Size # 2 Modular Supply unit. For outdoor installation. Includes Screened Intake
Show parts
Lookup Part! CD-LPD-VB-O-03-2M-TA-13 Size 3 LPD Celdek and V-Bank for Size # 2 Modular Supply unit. For outdoor installation. Includes Screened Intake
Show parts
Lookup Part! CD-LPD-VB-O-03-2M Size 3 LPD Celdek and V-Bank for Size # 2 Modular Supply unit. For outdoor installation. Includes Screened Intake
Show parts
Lookup Part! CD-LPD-VB-O-03-2M-HE-IL Size 3 LPD Celdek and V-Bank for Size # 2 Modular Supply unit. For outdoor installation. Includes Intake Louver.
Show parts
Lookup Part! CD-LPD-VB-O-03-2M-HEPA-IL Size 3 LPD Celdek and V-Bank for Size # 2 Modular Supply unit. For outdoor installation. Includes Intake Louver.
Show parts
Lookup Part! CD-LPD-VB-O-03-2M-TA-IL Size 3 LPD Celdek and V-Bank for Size # 2 Modular Supply unit. For outdoor installation. Includes Intake Louver.
Show parts
Lookup Part! CD-LPD-VB-O-03-2M-TA-13-IL Size 3 LPD Celdek and V-Bank for Size # 2 Modular Supply unit. For outdoor installation. Includes Intake Louver.
Show parts
Lookup Part! SFIH-02MDF Sloped Filtered Intake for Size #2 Modular Heater. 26.813" Wide X 53.625" Long X 31.313" High. Includes 2" MV EZ Kleen Metal Mesh Filters.
Show parts
Lookup Part! SFIH-02S Sloped Filtered Intake for Size #2 Standard Untempered Make-Up Air Unit with 12" blower wheel. 26.75" Wide x 29.25" Long x 31.5" High. Includes 2" MV EZ Kleen Metal Mesh Filters.
Show parts
Lookup Part! TL-02MDF TRUNKLINE - Extended Intake for size #2 Modular Heater. 24.75" Wide, 91.68" Long, 29.25" High. Includes intake hood with 2" EZ Kleen metal mesh filters, adjustable legs and 38" long extension.
Show parts
Lookup Part! TL-02S TRUNKLINE - Extended Intake for size 2, standard untempered MUA unit, with 12" blower 24.75" Width, 110" Length, 29.25" Height Includes intake hood with 2" EZ Kleen metal mesh filters, and 79.75" long extension.
Show parts
Lookup Part! VB-I-02MDF-TA V-Bank for Size # 2 Modular Heater with TA filters. For indoor installation. MERV 8 V-Bank Filters.
Show parts
Lookup Part! VB-O-02MDF-TA V-Bank for Size # 2 Modular Heater with TA Filters. Includes screened intake. For outdoor installation. MERV 8 V-Bank Filters.
Show parts
Lookup Part! VB-I-02MDF-TA-13 V-Bank for Size # 2 Modular Heater with TA filters. For indoor installation. MERV 13 V-Bank Filters.
Show parts
Lookup Part! VB-O-02MDF-TA-13 V-Bank for Size # 2 Modular Heater with TA Filters. Includes screened intake. For outdoor installation. MERV 13 V-Bank Filters.
Show parts
Lookup Part! VB-O-02M-HE V-Bank for Size # 2 Modular Make-Up Air unit with HE Filters. Includes screened intake. For outdoor installation. MERV 15 V-Bank Filters.
Show parts
Lookup Part! VB-O-02M-HE-IL V-Bank for Size # 2 Modular Make-Up Air unit with HE Filters. Includes intake louver. For outdoor installation. MERV 15 V-Bank Filters.
Show parts
Lookup Part! VB-O-02M-HEPA V-Bank for Size # 2 Modular Make-Up Air unit with HEPA filters. Includes screened intake. For outdoor installation.
Show parts
Lookup Part! VB-O-02M-TA-IL V-Bank for Size # 2 Modular Make-Up Air unit with TA Filters. Includes intake louver. For outdoor installation. MERV 8 V-Bank Filters
Show parts
Lookup Part! VB-O-02M-TA-13-IL V-Bank for Size # 2 Modular Make-Up Air unit with TA Filters. Includes intake louver. For outdoor installation. MERV 13 V-Bank Filters.
Show parts
Lookup Part! VB-O-02M-IL V-Bank for Size # 2 Modular Make-Up Air unit. EZ Metal Mesh Filters. Includes intake louver. For outdoor installation.
Show parts
Lookup Part! VB-I-02M-HE V-Bank for Size # 2 Modular Supply unit with HE filters. For indoor installation. MERV 15 V-Bank Filters.
Show parts
Lookup Part! VB-I-02M-HEPA V-Bank for Size # 2 Modular Supply unit with HEPA filters. For indoor installation.
Show parts
Lookup Part! VB-O-02M-HE-IH-EZ V-Bank for Size #2 Modular Make-Up Air unit with HE Filters. Includes intake hood with EZ filters. For outdoor installation. MERV 15 V-Bank Filters.
Show parts
Lookup Part! VB-O-02M-HEPA-IH-EZ V-Bank for Size #2 Modular Make-Up Air unit with HEPA filters. Includes intake hood with EZ filters. For outdoor installation.
Show parts
Lookup Part! VB-O-02M-TA-13-IH-EZ V-Bank for Size #2 Modular Make-Up Air unit with TA Filters. Includes intake hood with EZ filters. For outdoor installation. MERV 13 V-Bank Filters.
Show parts
Lookup Part! VB-O-02M-TA-IH-EZ V-Bank for Size #2 Modular Make-Up Air unit with TA Filters. Includes intake hood with EZ filters. For outdoor installation. MERV 8 V-Bank Filters.
Show parts
Lookup Part! VB-I-02MDF V-Bank with EZ filters for Size # 2 Modular Heater. EZ Metal Mesh Filters. For indoor installation.
Show parts
Lookup Part! VB-O-02MDF V-Bank with EZ filters for Size # 2 Modular Heater. EZ Metal Mesh Filters. Includes screened intake. For outdoor installation.
Show parts
Temperature Controls

No Temperature Controls Found.

Blower
Part
Lookup Part! G15-PB 15" forward curved, centrifugal blower. Pillow Block ball bearings. Galvanized finish. 1" x 27-1/8" Shaft. 2000-7500 CFM. 1800 max. RPM. Used in heated and non-heated supply fans.
Burner
Part
Lookup Part! EMC2-73KW4803 Electric Duct Insert for Size 2 Enclosure. 480V 3 phase, 73 KW maximum - 3 stages total, 1 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Uses A/CP-DO-120-QC Sensor and VT7225 Thermostat. Sensor and Thermostat not included. Coil is 22.63" wide and 23.63" tall.
 
Lookup Part!  - DP 11-1003 - [1 used] 2 Pole Contactor, used with EMC1-20KW2403, EMC1-20KW4803, EMC1-35KW4803, EMC1-50KW4803, EMC2-73KW4803, EMC2-100KW4803, EMC2-73KW6003, EMC3-52KW2403, EMC3-64KW2403, EMC3-175KW6003, EMC4-97KW2403, EMC4-300KW6003, EMC5-151KW2403, EMC5-257KW6003, EMC5-415KW6003, RTUEC-100KW6003, RTUEC-15KW2401, RTUEC-15KW4803, RTUEC-15KW6003, RTUEC-30KW6003, RTUEC-45KW4803, RTUEC-45KW6003, RTUEC-60KW2403, RTUEC-60KW6003, RTUEC-90KW6003, RTUEC1S-15KW2401, RTUEC1S-15KW4803, RTUEC1S-15KW6003, RTUEC1S-30KW6003, RTUEC1S-40KW2403, RTUEC1S-45KW4803, RTUEC1S-45KW6003, RTUEC1S-10KW2403, RTUEC1S-10KW4803, RTUEC1S-10KW6003, RTUEC1L-60KW6003, RTUEC4-90KW4803, RTUEC4-60KW6003, RTUEC4-60KW4803, RTUEC4-45KW4803, RTUEC4-30KW6003, RTUEC5-120KW2403, RTUEC5-150KW2403, and RTUEC5-240KW4803
 
Lookup Part!  - DP 11-1004 - [1 used] 3 Pole Contactor, used with EMC1-20KW2403, EMC1-20KW4803, EMC1-35KW4803, EMC1-50KW4803, EMC2-73KW4803, EMC2-100KW4803, EMC2-73KW6003, EMC3-52KW2403, EMC3-64KW2403, EMC3-175KW6003, EMC4-97KW2403, EMC4-300KW6003, EMC5-151KW2403, EMC5-257KW6003, EMC5-415KW6003, RTUEC-15KW4803, RTUEC-15KW6003, RTUEC-30KW6003, RTUEC-45KW4803, RTUEC-45KW6003, RTUEC1S-15KW4803, RTUEC1S-15KW6003, RTUEC1S-30KW6003, RTUEC1S-45KW4803, RTUEC1S-45KW6003, RTUEC1S-10KW2403, RTUEC1L-60KW6003, and RTUEC5-150KW2403
 
Lookup Part!  - DP 20-1001 - [1 used] Airflow Switch, used with Neptronic electric inserts
 
Lookup Part!  - DP 24-1002 - [1 used] Automatic Cutout, used with Neptronic electric inserts
 
Lookup Part!  - NW HEC0S02SS - [1 used] Circuit Board, used with EMC1-50KW4803, EMC1-72KW4803, EMC1-76KW6003, EMC2-45KW2403, EMC2-73KW4803, EMC2-100KW4803, EMC2-73KW6003, EMC2-119KW6003, EMC3-52KW2403, EMC3-64KW2403, EMC3-122KW4803, EMC3-122KW6003, RTUEC-100KW2403, RTUEC-100KW4803, RTUEC-15KW2401, RTUEC-30KW2401, RTUEC-30KW2403, RTUEC-45KW2403, RTUEC-45KW4803, RTUEC-60KW2403, RTUEC-60KW4803, RTUEC-60KW6003, RTUEC-90KW4803, RTUEC-90KW6003, RTUEC1S-15KW2401, RTUEC1S-20KW2401, RTUEC1S-30KW2403, RTUEC1S-40KW2403, RTUEC1S-45KW4803, RTUEC1L-60KW4803, RTUEC1L-60KW6003, RTUEC4-120KW6003, RTUEC4-90KW6003, RTUEC4-90KW4803, RTUEC4-60KW6003, RTUEC4-60KW4803, RTUEC4-45KW4803, RTUEC4-45KW2403, RTUEC4-30KW2403, and RTUEC5-120KW6003
 
Lookup Part!  - DP 24-2002 - [1 used] Manual Cutout, used with Neptronic electric inserts
 
Lookup Part!  - DW SSR50Y1 - [1 used] SCR, used with EMC1-20KW2403, EMC1-20KW4803, EMC1-35KW4803, EMC1-50KW4803, EMC1-35KW6003, EMC2-45KW2403, EMC2-73KW4803, EMC2-100KW4803, EMC2-73KW6003, EMC3-122KW4803, EMC3-175KW6003, EMC4-300KW6003, EMC5-257KW4803, EMC5-334KW4803, EMC5-257KW6003, EMC5-415KW6003, RTUEC-100KW6003, RTUEC-15KW2401, RTUEC-15KW2403, RTUEC-30KW2403, RTUEC-30KW4803, RTUEC-30KW6003, RTUEC-45KW4803, RTUEC-45KW6003, RTUEC-60KW4803, RTUEC-60KW6003, RTUEC-90KW4803, RTUEC-90KW6003, RTUEC1S-15KW2401, RTUEC1S-15KW2403, RTUEC1S-30KW2403, RTUEC1S-30KW4803, RTUEC1S-30KW6003, RTUEC1S-45KW4803, RTUEC1S-45KW6003, RTUEC1S-10KW2403, RTUEC1L-60KW2403, RTUEC1L-60KW4803, RTUEC1L-60KW6003, RTUEC4-150KW6003, RTUEC4-120KW4803, RTUEC4-60KW6003, RTUEC4-60KW2403, RTUEC4-45KW4803, RTUEC4-45KW2403, RTUEC4-30KW6003, RTUEC4-30KW4803, RTUEC4-30KW2403, RTUEC5-120KW4803, RTUEC5-120KW6003, RTUEC5-150KW4803, RTUEC5-150KW6003, RTUEC5-180KW4803, RTUEC5-180KW6003, RTUEC5-210KW6003, and RTUEC5-240KW6003
 
Lookup Part!  - DP 10-8003 - [1 used] Step Down Transformer 480 VAC to 24 VAC, used with EMC1-35KW4803, EMC1-50KW4803, EMC1-72KW4803, EMC2-73KW4803, RTUEC-100KW4803, RTUEC-45KW4803, RTUEC-60KW4803, RTUEC-90KW4803, RTUEC1S-45KW4803, RTUEC1L-60KW4803, RTUEC4-90KW4803, RTUEC4-60KW4803, and RTUEC4-45KW4803
Replacement Parts
Part
Lookup Part!  - [12 used] 33008 A0003208 - 3/8" WASHERS
Lookup Part!  - [6 used] 8003 CONDUIT CONNECTOR - 90deg; 1/2" Bridgeport, 1/2" long thread
Lookup Part!  - [1 used] G15BRACKET Motor Platform for G15 Blower Wheel
Lookup Part!  - [2 used] Scroll Plate Scroll Plate Angle Support for G7/G10/G12G15/G18 Blower Wheel - Ship With Mounting Hardware.
Common Heater Components
Lookup Part!  - [1 used] HMI_Bracket 20 GA. Galvanized. Used on IBT controls
Common Heater Electrical Components
Lookup Part!  - [1 used] SU201M-K2 CIRCUIT BREAKER - 2 AMP Circuit Breaker Used for Commercial Heaters. Trip Curve 9. Old P/N S201U-K2
Controller&HMI
Lookup Part!  - [1 used] HMI_01_MUA_POPULATED HMI assembly. Preprogrammed for use with MUA Board. Includes CASHMI PCB, 4 mounting screws, 16 ga. SS backing plate, membrane switches & gasket. HMI should have populated RH sensor.
Direct Fired Sheet Metal Components
Lookup Part!  - [2 used] MD12MR DF 1-2 MAIN RAIL 45.25X8 GALV14GA REV5
Lookup Part!  - [1 used] D13TDSPDPRL DF 1-3 Top Door Support w/Integrated Drip Rail
Lookup Part!  - [1 used] D2BOTTH DF 2 Bottom Hinged
Lookup Part!  - [1 used] D2DOORH DF 2 Burner Hinged Door
Lookup Part!  - [1 used] D2LTFPH DF 2 Left Front Post Hinged
Lookup Part!  - [1 used] D2LRDJNVH DF 2 Left Rear Door Jamb with No View Port Hinged
Lookup Part!  - [1 used] D2LIDDPRL DF 2 LID w/Integrated Drip Rail
Lookup Part!  - [1 used] D2RTFPH DF 2 Right Front Post Hinged
Lookup Part!  - [2 used] MD15LCOVER Door Louver Cover for Commercial DF 1-5 Units.
Lookup Part!  - [4 used] MLIFTL LIFTING LUG
Electric Heater Sheet Metal Components
Lookup Part!  - [1 used] EH2RRDJH EH 2 Right Rear Door Jamb Hinged
Exhaust Fan Whiz Nuts & Bolts
Lookup Part!  - [22 used] 800043 A0005678 - Bolt Whiz 3/8-16 X 1 1/2, Steel Grade 5 Minimum (3 Evenly Spaced Radial Marks)
Lookup Part!  - [8 used] 5/16-18 WHIZNUT Zinc-Plated Grade 5 Steel Serrated-Flange Locknut, 5/16"-18 Thread Size, 11/16" Flange Diameter, 9/32" Overall Height.
Exhaust Fan Wiring Options
Lookup Part!  - [14 used] 8002 CONDUIT - 1/2" LT FLEX JIC. (Price per Foot)
Miscellaneous Electrical Parts
Lookup Part!  - [1 used] CAT5_3FT 3 Foot Long CAT5 Cable
Lookup Part!  - [2 used] 800041 Bolt Whiz 10-32 X 1/2, SFB103212Z, Steel Grade 5 Minimum (3 Evenly Spaced Radial Marks)
Lookup Part!  - [2 used] 800030 Nut Whiz 10-32, SFLN1032Z, Steel, Large Flange
Lookup Part!  - [1 used] MUA Board Printed Circuit board for use in heaters. Used in conjunction with CAS HMI.
Miscellaneous Heater Components
Lookup Part!  - [6 used] NBB4000516 5/16" NUTS
Lookup Part!  - [10 used] WA4000516 5/16" WASHERS
Lookup Part!  - [1 used] 3M467J Captiveaire Factory Direct sticker
Lookup Part!  - [50 used] INSULATION/sq ft INSULATION (Price per Sq Foot)
Lookup Part!  - [8 used] HG-OTA100 Removable Door Hinge used on Pollution Control Units and KB Blowers
Lookup Part!  - [2 used] UNI VENT II - 20" Vinyl coated polyurethane foam, uv stabilized, fire retardant with continuous double glue strip. Used to seal louver cover and gaps in vbank filters. 20" Length.
Miscellaneous Hood Parts
Lookup Part!  - [6 used] SCREW 10-24X3/8 ZINC RD HD SLOTTED MS - DOOR HANDLE SCREW 10-24X3/8 ZINC RD HD SLOTTED MS - Used on UC door handles and MUA door handles
Lookup Part!  - [1 used] 104778 SEALANT - 10.3 oz Silicone Silver/Aluminum Sealant. 350 deg silicone used in hoods. (item #104778)
Pollution Control Hardware
Lookup Part!  - [48 used] 90272A829 Zinc-Plated Steel Pan Head Phillips Machine Screw, 10-32 Thread, 1/2" Length
Product Manuals
Lookup Part!  - [1 used] MANUAL ELECTRIC Manual for Commercial Electric Heater
RTU Miscellaneous Components
Lookup Part!  - [8 used] A7-10-351-20 Black Compression Handle Latch and Clasp
Supply Fan Miscellaneous Parts
Lookup Part!  - [2 used] 2T4000516040000 5/16" BOLTS 4" LONG
Lookup Part!  - [266 used] SB6-4-RIVET RIVET - 3/16" Diameter, .126 To .250 Grip Range, SB6-4 Button Head Steel/Steel. Replaced 800075.
Lookup Part!  - [16 used] ITH41234 SHEET METAL SCREWS 12-14 X 3/4"
Supply Fan Sheet Metal Components
Lookup Part!  - [2 used] M2EFLS 2 END FLASHING
Lookup Part!  - [1 used] B25DDB AHU 2 BOTTOM
Lookup Part!  - [1 used] B2LIDDPRL AHU 2 LID w/Intergrated Drip Rail
Lookup Part!  - [2 used] B2MNRL AHU 2 MAIN RAIL
Lookup Part!  - [1 used] B2RTFPH AHU 2 Right Front Post Hinged
Lookup Part!  - [2 used] B2BLBC BLOWER BRACE
Lookup Part!  - [4 used] MCONWAS Connecting Washer 12 Gauge 2-7/8" x 2-7/8"
Lookup Part!  - [1 used] B2G15COL G15 COLLAR
Lookup Part!  - [4 used] M2HSUP HORIZONTAL SUPPORT
Supply Fan Vibration Isolators
Lookup Part!  - [4 used] L1VIB Motor Frame Vibration Eliminator 1" Out. Dia. X 1/4" Tall, Rubber (Black) New Style, 5/16-18 x 1/2 dual studs. Durometer = 50
Thermostats/Sensors
Lookup Part!  - [1 used] A/CP-DO-240-QC 10K, Type II thermistor with 6" probe. 20' wire leads. (Replaces part# A/CP-DO-120-QC)
Curbs
Part
Lookup Part! CRB31X79X8INS ROOF CURB - 31" Wide X 79" Long X 8" High, Insulated. For the # 2 Modular Heater.
Lookup Part! CRB31X79X10INS ROOF CURB - 31" Wide X 79" Long X 10" High, Insulated. For the # 2 Modular Heater.
Lookup Part! CRB31X79X14INS ROOF CURB - 31" Wide X 79" Long X 14" High, Insulated. For the # 2 Modular Heater.
Lookup Part! CRB31X79X15INS ROOF CURB - 31" Wide X 79" Long X 15" High, Insulated. For the # 2 Modular Heater.
Lookup Part! CRB31X79X16INS ROOF CURB - 31" Wide X 79" Long X 16" High, Insulated. For the # 2 Modular Heater.
Lookup Part! CRB31X79X18INS ROOF CURB - 31" Wide X 79" Long X 18" High, Insulated. For the # 2 Modular Heater.
Lookup Part! CRB31X79X20INS ROOF CURB - 31" Wide X 79" Long X 20" High. Insulated.
Lookup Part! CRB31X79X20INS-BTC BOLT TOGETHER ROOF CURB -31" X 79" X 20" High, Insulated. 18 GA Galvanized. Ships Flat. Pitched Curb Option Not Available with Bolt Together Curbs.
Lookup Part! CRB31X79X24INS CURB - 31" Wide X 79" Long X 24" High, Insulated. For the # 2 Modular Heater.
Lookup Part! CRB31X79X26INS CURB - 31" Wide X 79" Long X 26" High, Insulated. For the # 2 Modular Heater.
Lookup Part! CRB31X79X28INS CURB - 31" Wide X 79" Long X 28" High, Insulated. For the # 2 Modular Heater.
Lookup Part! CRB31X79X30INS CURB - 31" Wide X 79" Long X 30" High, Insulated. For the # 2 Modular Heater.
Lookup Part! CRB31X79X36INS CURB - 31" Wide X 79" Long X 36" High, Insulated. For the # 2 Modular Heater.
Lookup Part! CRB31X79X40INS ROOF CURB - 31" Wide X 79" Long X 40" High, Insulated. For the # 2 Modular Heater.
Options
Parts
Lookup Part! CSMDTIL Commercial Smoke Detector Interlock (Detector By Others)
Lookup Part! D4120-DST-1.5-C Duct Mounted Smoke Detector For Commercial Direct Fired Heater. Complete with detector (D4120) and sampling tube (DST-1.5). Ships Loose
Show parts
Lookup Part! CABHTR200W Control panel enclosure heater, includes 200w, 120v heater and thermostat (10 degree setting). Requires convenience outlet option (power by others). Recommended for winter design temperature less than 0°F. - Old Controls
Show parts
Lookup Part! CWCM2-1 CW Coil Module for Size 2 Modular Fans - 1,500 thru 5,300 CFM (5 Ton, 5WS0604B-37.5x36.0) Not stocked. Allow 5-6 weeks lead time. Temperature controls, mixing valves, thermostats, and freeze protection by others.
Show parts
Lookup Part! CWCM2-2 CW Coil Module for Size 2 Modular Fans - 1,500 thru 5,300 CFM (10 Ton, 5WS1004B-37.5x36.0) Not stocked. Allow 5-6 weeks lead time. Temperature controls, mixing valves, thermostats, and freeze protection by others.
Show parts
Lookup Part! CWCM2-3 CW Coil Module for Size 2 Modular Fans - 1,500 thru 5,300 CFM (15 Ton, 5WS1204B-37.5x36.0) Not stocked. Allow 5-6 weeks lead time. Temperature controls, mixing valves, thermostats, and freeze protection by others.
Show parts
Lookup Part! CWCM2-4 CW Coil Module for Size 2 Modular Fans - 1,500 thru 5,300 CFM (20 Ton, 5WS1404B-37.5x36.0) Not stocked. Allow 5-6 weeks lead time. Temperature controls, mixing valves, thermostats, and freeze protection by others.
Show parts
Lookup Part! Ecoat-AC-2 Size 2 Cooling Coil Ecoating option for MPU-AC options. Adds 5-6 week lead time.
Lookup Part! Ecoat-2-MPU-RH Size 2 Cooling Coil Ecoating option for MPU-RH options. Adds 5-6 week lead time.
Lookup Part! Ecoat-2-C Size 2 Cooling Coil Ecoating option for standard MPU, DX and Chilled Water Coils. Adds 5-6 week lead time.
Lookup Part! 5 Ton 2 Circuit 1 Phase 208/230V Condensing Package (2) 2.5 Ton (5 Ton Total), Dual Circuit Condensing Units. 1 phase 208-230V. Air Cooled. Includes: Disconnect Switch. R410 refrigerant and piping by others. Shipping included in price. 24ACC430A003
Show parts
Lookup Part! 5 Ton 2 Circuit 208/230V Condensing Package (2) 2.5 Ton (5 Ton Total), Dual Circuit Condensing Units. 3 phase 208/230V. Air Cooled. Includes: Disconnect Switch. R410 refrigerant and piping by others. Shipping included in price. 24ABB330A005
Show parts
Lookup Part! CTR-CC DX Cooling Intake Air Thermostat and Relays Mounted in Unit - Set Point For Thermostat Should Be 85°F.
Show parts
Lookup Part! CTR-RPI-CC Cooling Thermostat and Relay Mounted in Fan with Remote Panel Interlock - Set Point For Thermostat Should Be 85°F.
Show parts
Lookup Part! IACT-CC Intake Air Single Stage Cooling Thermostat Mounted in Unit - Set Point For Thermostat Should Be 85°F for MPU, 60°F for MPU-AC. Low Limit cooling thermostat.
Show parts
Lookup Part! A10SDAD-A 180° Side Discharge Air Diffuser A10, A12, A15. For Commercial Heaters.
Lookup Part! A10DDAD3W-A 3-Way Down Discharge Air Diffuser A10, A12, A15. For Commercial Fans.
Show parts
Lookup Part! A10DDAD4W-A 4-Way Down Discharge Air Diffuser A10, A12, A15. For Commercial Fans.
Show parts
Lookup Part! A10DDAD-A 45° Down Discharge Air Diffuser A10, A12, A15. For Commercial Fans.
Lookup Part! CCDTP2 Downturn Plenum for Size 2 Cooling Coil Module - Required for Down Discharge Cooling Coil Applications
Show parts
Lookup Part! ECRPI Evap Cooler Cooling Interlock Between Remote Panel and Heater
Lookup Part! EC-FPDK-Evap Freeze Protection Drain Control kit for Evaporative Coolers. Includes 3-Way water solenoid valve 8316G064 (shipped loose), Pressure switch installed upstream of 2way solenoid in unit, Brass Tee, 2 NPT half inch nipples, and two stage thermostat T678A1361. Field wiring required by others for 3-way valve. For both Celdek and Standard V-bank type Configurations.
Show parts
Lookup Part! CD-G-32x25x12 Glasdek Media for size 2 celdek evaporative cooler intake. 32in wide x 25in tall x 12in thick.
Lookup Part! CD-G-36x30x12 Glasdek Media for size 3 celdek evaporative cooler intake. 36in wide x 30in tall x 12in thick.
Lookup Part! EGL-MUA Extended Grease Lines for Commercial MUA Fans. Grease Zerk fittings installed on outside of fan housing, directly below disconnect switch. Requires (2) 25/64" holes drilled in cabinet exterior.
Show parts
Lookup Part! XB-2 Extra Set of V-Belts. Only to be ordered as fan option at time fan is ordered.
Lookup Part! MIAMI-DADE NOA-2 Supply Miami Dade Impact and Wind Load Certification +30 / -130 PSF - Miami Dade County Product Control Approved. Florida Building Code approval. Roof Mount Exhaust Curbs up to 20" high must be 18 gauge Aluminized.
Lookup Part! MWP-HMUA Melink Wiring Package for Heated Make-Up Air Units. 3 Phase Inverter duty Motor must be selected.
Show parts
Lookup Part! IBT EVAP INTERLOCK Layer Control for IBT Evap
Show parts
Lookup Part! IHC-EI2 Indoor Hanging Cradle For The Size 2 Electric Heater. 2 HSA125 Hanging Isolators per Uni-Strut Included.
Show parts
Lookup Part! AC-Interlock Cooling Interlock Relay. 24VAC Coil. 120V Contacts. Locks out burner circuit when AC is energized.
Show parts
Lookup Part! CLCOMM_REV04 CASLink building monitoring system communications module. Requires internet & field wired ethernet connection or 3G cellular service. Includes Rev 3 Comm Module, RJ45 to modbus converter, 3 FT cat5 cable, and 1 FT of shielded twisted pair.
Show parts
Lookup Part! DDC-IP BACnet Monitoring Remote IP BACnet monitoring for supply fans.
Show parts
Lookup Part! DDC-MSTP BACnet Monitoring Remote MSTP BACnet monitoring
Show parts
Lookup Part! FECONTABI Field Wired Exhaust Contactor After Blower Interlock. Rated 23 Amps. Starts up to (2) Single Phase Motors. 2HP max. 115V, 3HP max. 240V. Starts one Three Phase Motor. 5HP max. 208V, 7.5HP max 230v 15HP max. 460V. Overload not Included
Show parts
Lookup Part! FECONTBBI Field Wired Exhaust Contactor Before Blower Interlock. Rated 23 Amps. Starts up to (2) Single Phase Motors. 2HP max. 115V, 3HP max. 240V. Starts one Three Phase Motor. 5HP max. 208V, 7.5HP max 230v, 15HP max. 460V. Overload not Included.
Show parts
Lookup Part! EXHSTARTER1-3AAFS Exhaust Fan Starter Installed in size 1, 2, or 3 heater powered after airflow swtich
Lookup Part! EXHSTARTER1-3BBI Exhaust Fan Starter Installed in size 1, 2, or 3 heater powered before blower interlock.
Lookup Part! Exhaust on Fire Exhaust on Fire
Lookup Part! BASMB-MUA-MOD BAS control for MUA mixing box
Show parts
Lookup Part! OCCUPIED SCHEDULING Occupied Scheduling Defaulted for IBT/RTU.
Lookup Part! OPPSIDE-EH-CTRLS Mount motor and controls on opposite side of heater. Custom electric coil required. Contact engineering. Lead time 14 days.
Lookup Part! SPC3 Single point connection for three phase electric heaters - Not used with multiple heat modules.
Lookup Part! Supply Fan Preset Speed Supply Fan Preset Speed Input to PCB. Field Wired.
Lookup Part! 1 Stage Cooling Terminals (Cooling by Others) 1 Stage Cooling Terminals (Cooling by Others)
Lookup Part! 2 Stage Cooling Terminals (Cooling by Others) 2 Stage Cooling Terminals (Cooling by Others)
Lookup Part! 6 Pole Rotary Disconnect 6 Pole 40 Amp Rotary Disconnect for Fans. Includes Switch, switch handle, mounting plate, gasket, and junction box.
Show parts
Lookup Part! CLOGFILTHMI Clogged Filter Switch with Notification on HMI
Show parts
Lookup Part! CLOGFILT Clogged Filter Switch with Light on Remote Panel
Show parts
Lookup Part! CVOUTLET GFCI 15 amp Convenience Outlet For Heater Enclosure. Power supply by others - Includes receptacle and J box.
Lookup Part! EXTENDED-DROP Extended Drop for Commercial Heaters and Supply Fans. Extends the power and remote panel connections to the unit to 20' of total length.
Lookup Part! Purge mode Purge option selected. Allows the user to purge the space by manually activtating on the HMI.
Show parts
Lookup Part! Single Electrical Cabinet LED Lights Single Electrical Cabinet LED Lights Used on Modular MUA Units
Show parts
Lookup Part! DBWSLC-EH-2 Double Wall Steel Liner for EH. Includes Roof, Floor, and Doors Double Wall Liners
Show parts
Lookup Part! SPRCM-MUA-MOD Static Pressure Mixing box Control (Mounted in Unit, preset to: -0.01 and 0.02) Used with MUA board
Show parts
Lookup Part! MB2-MPU Support shell for Size 2 Modular Package Unit. Includes control vestibule. Includes condenser supports. Does not include return air or inlet air damper.
Show parts
Lookup Part! MB2-MUA Mixing Box for Size 2 Modular Supply Fan. Use with MUA controls.
Show parts
Lookup Part! MB2-IBT-MAN Mixing Box for Size 2 IBT. Actuator Control By 0-10V Output on IBT Board.
Show parts
Lookup Part! MB2-NC Mixing Box for Size 2 Modular Supply Fan. Actuator and Controls provided by others.
Show parts
Lookup Part! MB2-BAS Mixing Box for Size 2 Modular Supply Fan. Actuator Control by 2-10 VDC input.
Show parts
Lookup Part! MB2-SP Mixing Box for Size 2 Modular Supply Fan. Actuator Control by Static Pressure. Photohelic included.
Show parts
Lookup Part! MB2-MP Mixing Box for Size 2 Modular Supply Fan. Actuator Control by Manual Potentiometer. Manual Potenentiometer included.
Show parts
Lookup Part! MB2-TP Mixing Box for Size 2 Modular Supply Fan. 2-Position Actuator Control. Interlock field wired by others. Spring Return to Outside Air Position.
Show parts
Lookup Part! MPU2-DF-10-208-1 10 Ton, Dual Circuit (5/5) Modular Packaged Cooling Option for Size 2 DF/EH Modular Packaged Unit. Includes Condenser, DX Coil, Filter/Dryer Kit, Hard Start Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (3,600 to 5,000 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 208V, 1 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 3EZ0802B
Show parts
Lookup Part! MPU2-DF-10-208-3 10 Ton, Dual Circuit (5/5) Modular Packaged Cooling Option for Size 2 DF/EH Modular Packaged Unit. Includes Condenser, DX Coil, Filter/Dryer Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (3,600 to 5,000 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 208V, 3 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 3EZ0802B
Show parts
Lookup Part! MPU2-DF-10-460-3 10 Ton, Dual Circuit (5/5) Modular Packaged Cooling Option for Size 2 DF/EH Modular Packaged Unit. Includes Condenser, DX Coil, Filter/Dryer Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (3,600 to 5,180 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 460V, 3 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 3EZ0802B
Show parts
Lookup Part! MPU2-DF-10-575-3 10 Ton, Dual Circuit (5/5) Modular Packaged Cooling Option for Size 2 DF/EH Modular Packaged Unit. Includes Condenser, DX Coil, Filter/Dryer Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (3,600 to 5,000 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 575V, 3 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 3EZ0802B
Show parts
Lookup Part! MPU2-DF-5-208-1 5 Ton, Single Circuit Modular Packaged Cooling Option for Size 2 DF/EH Modular Packaged Unit. Includes Condenser, DX Coil, Filter/Dryer Kit, Hard Start Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (2,000 to 3,000 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 208V, 1 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 3EZ1001R
Show parts
Lookup Part! MPU2-DF-5-208-3 5 Ton, Single Circuit Modular Packaged Cooling Option for Size 2 DF/EH Modular Packaged Unit. Includes Condenser, DX Coil, Filter/Dryer Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (2,000 to 3,000 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 208V, 3 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 3EZ1001R
Show parts
Lookup Part! MPU2-DF-5-460-3 5 Ton, Single Circuit Modular Packaged Cooling Option for Size 2 DF/EH Modular Packaged Unit. Includes Condenser, DX Coil, Filter/Dryer Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (2,000 to 3,000 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 460V, 3 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 3EZ1001R
Show parts
Lookup Part! MPU2-DF-5-575-3 5 Ton, Single Circuit Modular Packaged Cooling Option for Size 2 DF/EH Modular Packaged Unit. Includes Condenser, DX Coil, Filter/Dryer Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (2,000 to 3,000 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 575V, 3 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 3EZ1001R
Show parts
Lookup Part! MPU2-DF-7.5-208-1 7.5 Ton, Dual Circuit (2.5/5) Modular Packaged Cooling Option for Size 2 DF/EH Modular Packaged Unit. Includes Condenser, DX Coil, Filter/Dryer Kit, Hard Start Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (2,700 to 4,500 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 208V, 1 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 3EZ1101C
Show parts
Lookup Part! MPU2-DF-7.5-208-3 7.5 Ton, Dual Circuit (2.5/5) Modular Packaged Cooling Option for Size 2 DF/EH Modular Packaged Unit. Includes Condenser, DX Coil, Filter/Dryer Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (2,700 to 4,500 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 208V, 3 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 3EZ1101C
Show parts
Lookup Part! MPU2-DF-8-208-1 8 Ton, Dual Circuit (3/5) Modular Packaged Cooling Option for Size 2 DF/EH Modular Packaged Unit. Includes Condenser, DX Coil, Filter/Dryer Kit, Hard Start Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (2,900 to 4,800 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 208V, 1 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 3EZ1101D
Show parts
Lookup Part! MPU2-DF-8-208-3 8 Ton, Dual Circuit (3/5) Modular Packaged Cooling Option for Size 2 DF/EH Modular Packaged Unit. Includes Condenser, DX Coil, Filter/Dryer Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (2,900 to 4,800 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 208V, 3 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 3EZ1101D
Show parts
Lookup Part! MPU2-DF-8-460-3 8 Ton, Dual Circuit (3/5) Modular Packaged Cooling Option for Size 2 DF/EH Modular Packaged Unit. Includes Condenser, DX Coil, Filter/Dryer Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (2,900 to 4,800 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 460V, 3 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 3EZ1101D
Show parts
Lookup Part! MPU2-DF-8-575-3 8 Ton, Dual Circuit (3/5) Modular Packaged Cooling Option for Size 2 DF/EH Modular Packaged Unit. Includes Condenser, DX Coil, Filter/Dryer Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (2,900 to 4,800 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 575V, 3 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 3EZ1101D
Show parts
Lookup Part! MPU2-DF-10-AC-208-1 10 Ton, Dual Circuit (5/5) Modular Packaged AC Cooling Option for Size 2 DF/EH Modular Packaged Unit. Includes Condenser, DX Coil, Filter/Dryer Kit, Hard Start Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (1500 to 3000 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 208V, 1 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 3EY1203T
Show parts
Lookup Part! MPU2-DF-10-AC-208-3 10 Ton, Dual Circuit (5/5) Modular Packaged AC Cooling Option for Size 2 DF/EH Modular Packaged Unit. Includes Condenser, DX Coil, Filter/Dryer Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (1500 to 3,000 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 208V, 3 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 3EY1203
Show parts
Lookup Part! MPU2-DF-10-AC-460-3 10 Ton, Dual Circuit (5/5) Modular Packaged AC Cooling Option for Size 2 DF/EH Modular Packaged Unit. Includes Condenser, DX Coil, Filter/Dryer Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (1500 to 3,000 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 460V, 3 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 3EY1203
Show parts
Lookup Part! MPU2-DF-10-AC-575-3 10 Ton, Dual Circuit (5/5) Modular Packaged AC Cooling Option for Size 2 DF/EH Modular Packaged Unit. Includes Condenser, DX Coil, Filter/Dryer Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (1500 to 3,000 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 575V, 3 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 3EY1203
Show parts
Lookup Part! MPU2-DF-5-AC-208-1 5 Ton, Single Circuit Modular Packaged AC Cooling Option for Size 2 DF/EH Modular Packaged Unit. Includes Condenser, DX Coil, Filter/Dryer Kit, Hard Start Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (1,000 to 2,750 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 208V, 1 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 3EY1102T
Show parts
Lookup Part! MPU2-DF-5-AC-208-3 5 Ton, Single Circuit Modular Packaged AC Cooling Option for Size 2 DF/EH Modular Packaged Unit. Includes Condenser, DX Coil, Filter/Dryer Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (1,000 to 2,750 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 208V, 3 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 3EY1102
Show parts
Lookup Part! MPU2-DF-5-AC-460-3 5 Ton, Single Circuit Modular Packaged AC Cooling Option for Size 2 DF/EH Modular Packaged Unit. Includes Condenser, DX Coil, Filter/Dryer Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (1,000 to 2,750 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 460V, 3 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 3EY1102
Show parts
Lookup Part! MPU2-DF-5-AC-575-3 5 Ton, Single Circuit Modular Packaged AC Cooling Option for Size 2 DF/EH Modular Packaged Unit. Includes Condenser, DX Coil, Filter/Dryer Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (1,000 to 2,750 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 575V, 3 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 3EY1102
Show parts
Lookup Part! MPU2-DF-7.5-AC-208-1 7.5 Ton, Dual Circuit (2.5/5) Modular Packaged AC Cooling Option for Size 2 DF/EH Modular Packaged Unit. Includes Condenser, DX Coil, Filter/Dryer Kit, Hard Start Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (1125 to 3000 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 208V, 1 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 3EY1402
Show parts
Lookup Part! MPU2-DF-7.5-AC-208-3 7.5 Ton, Dual Circuit (2.5/5) Modular Packaged AC Cooling Option for Size 2 DF/EH Modular Packaged Unit. Includes Condenser, DX Coil, Filter/Dryer Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (1125 to 3000 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 208V, 3 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 3EY1402
Show parts
Lookup Part! MPU2-DF-8-AC-208-1 8 Ton, Dual Circuit (3/5) Modular Packaged AC Cooling Option for Size 2 DF/EH Modular Packaged Unit. Includes Condenser, DX Coil, Filter/Dryer Kit, Hard Start Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (1200 to 3000 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 208V, 1 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 3EY1302T
Show parts
Lookup Part! MPU2-DF-8-AC-208-3 8 Ton, Dual Circuit (3/5) Modular Packaged AC Cooling Option for Size 2 DF/EH Modular Packaged Unit. Includes Condenser, DX Coil, Filter/Dryer Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (1200 to 3000 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 208V, 3 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 3EY1302T
Show parts
Lookup Part! MPU2-DF-8-AC-460-3 8 Ton, Dual Circuit (3/5) Modular Packaged AC Cooling Option for Size 2 DF/EH Modular Packaged Unit. Includes Condenser, DX Coil, Filter/Dryer Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (1200 to 3000 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 460V, 3 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 3EY1302T
Show parts
Lookup Part! MPU2-DF-8-AC-575-3 8 Ton, Dual Circuit (3/5) Modular Packaged AC Cooling Option for Size 2 DF/EH Modular Packaged Unit. Includes Condenser, DX Coil, Filter/Dryer Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (1200 to 3000 cfm) NOT BUILT WITH OPPOSITE SIDE CONTROLS OR OPPOSITE AIRFLOW DIRECTION. CONDENSERS REQUIRE SEPARATE 575V, 3 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 3EY1302T
Show parts
Lookup Part! A2UPDISCH Up Discharge Construction
Show parts
Lookup Part! A2-D-MBDD INS Motorized Back Draft Insulated Damper 22.75" X 24" for Size 2 Standard & Modular Heater Units w/Extended Shaft, Standard Galvanized Construction, 3/4" Rear Flange, Low Leakage, LF120S Actuator Included. Insulated blades and frame. Thermally broken blades.
Show parts
Lookup Part! A2-D-MBDD Motorized Back Draft Damper 22.75" X 24" for Size 2 Standard & Modular Heater Units w/Extended Shaft, Standard Galvanized Construction, 3/4" Rear Flange, Low Leakage, LF120S Actuator Included
Show parts
Lookup Part! A2-MBDD-SL Motorized Back Draft Discharge Damper Shipped Loose 30" X 30" for Size 2 Units w/Extended Shaft, Standard Galvanized Construction, 3/4" Rear Flange, Low Leakage, NFBUP-S Actuator Included, Field Installation Required. Damper, actuator & actuator cover (p/n ACTCOVERMOD) factory assembled.
Show parts
Lookup Part! Full Crating for Heater Full crating for commercial heaters for shipping.
Lookup Part! ENAM-1 Tan Enamel Coating (exterior walls/roof) For Heaters with 7"-15" blower wheels, includes casing and intakes. Consult factory for other colors. Sherwin Williams p/n F75KXN5809-4347, (AX = A0006229)
Lookup Part! Condenser_Locking_Caps_2 Locking caps for double condenser units. Consists of 4 locking caps, part# NCP-4, and 1 key, part# NC-KEY.
Show parts
Lookup Part! Condenser_Locking_Caps_1 Locking caps for single condenser units. Consists of 2 locking caps, part# NCP-4, and 1 key, part# NC-KEY.
Show parts
Lookup Part! DX 2-1 KIT-R410A DX 2-1 Kit R410A. Dual Circuit 5 Ton. Includes Filter Drier, Sight Glass, and Thermal Expansion Valve for DX units. Installation by others. Includes R410A TXV. Installation by others. Includes R410A TXV.
Show parts
Lookup Part! DX 2-2 KIT-R410A DX 2-2 Kit R410A. Dual Circuit 10 Ton. Includes Filter Drier, Sight Glass, and Thermal Expansion Valve for DX units. Installation by others. Includes R410A TXV. Installation by others. Includes R410A TXV.
Show parts
Lookup Part! DX 2-3 KIT-R410A DX 2-3 Kit R410A. Dual Circuit 15 Ton. Includes Filter Drier, Sight Glass, and Thermal Expansion Valve for DX units. Installation by others. Includes R410A TXV. Installation by others. Includes R410A TXV.
Show parts
Lookup Part! DX 2-4 KIT-R410A DX 2-4 Kit R410A. Dual Circuit 20 Ton. Includes Filter Drier, Sight Glass, and Thermal Expansion Valve for DX units. Installation by others. Includes R410A TXV. Installation by others. Includes R410A TXV.
Show parts
Lookup Part! ShipLoose-1C-1PH Ship Condenser Loose - Single Condenser, Single Phase - Condenser Disconnect Shipped Loose. All piping and wiring between indoor and outdoor units by others.
Show parts
Lookup Part! ShipLoose-1C-3PH Ship Condenser Loose - Single Condenser, Three Phase - Condenser Disconnect Shipped Loose. All piping and wiring between indoor and outdoor units by others.
Show parts
Lookup Part! ShipLoose-2C-1PH Ship Condensers Loose - Two Condensers, Single Phase - Condenser Disconnects Shipped Loose. All piping and wiring between indoor and outdoor units by others.
Show parts
Lookup Part! ShipLoose-2C-3PH Ship Condensers Loose - Two Condensers, Three Phase - Condenser Disconnects Shipped Loose. All piping and wiring between indoor and outdoor units by others.
Show parts
Lookup Part! SP-MPU-1C Single Point MPU Connection, 1 Condenser.
Show parts
Lookup Part! SP-MPU-2C Single Point MPU Connection, 2 Condensers.
Show parts
Lookup Part! MELIM-2 Size 2 Moisture Eliminator Option for DX Coil, MPUs and Chilled Water Coils - allows cooling coil face velocity to increase to 650 fpm. Increases cooling coil max cfm to 6000 cfm.
Show parts
Lookup Part! MPU2-RH Size 2 MPU Reheat Option. Reheat uses warm liquid refrigerant. Reheat runs continuously in stage 1 circuit. Option should not be used if entering air dew point is below 65 degrees F. Nominal capacity 14.9 MBH. Increases max CFM to 3250
Show parts
Lookup Part! MELIM-2-AC Size 2 MPU-AC Moisture Eliminator Option - allows cooling coil face velocity to increase to 650 fpm. Increases cooling coil max cfm to 3250 cfm.
Show parts
Lookup Part! D-Hanger Curb Duct Hanger - 1-1/4" Angle Iron Frame Welded to Curb to support standard size ductwork. Priced per curb. Only available when curb assembly is ordered.
Lookup Part! MB2-MERV 13-EXTRA Extra set of MERV 13 filters for Size 2 Mixing Box. Uses 2 20 x 25 x 2 inch filters and 1 16 x 25 x 2 inch filters.
Show parts
Lookup Part! MB2-MERV 8-EXTRA Extra set of MERV 8 filters for Size 2 Mixing Box. Uses 2 20 x 25 x 2 inch filters and 1 16 x 25 x 2 inch filters.
Show parts
Lookup Part! MB2-MERV 13 MERV 13 filter option for Size 2 Mixing Box or Condenser Support. Mixing Box or Condenser Support must be selected for this option. Uses 2 20 x 25 x 2 inch filters and 1 16 x 25 x 2 inch filters.
Show parts
Lookup Part! MB2-MERV 8 MERV 8 filter option for Size 2 Mixing Box or Condenser Support. Mixing Box or Condenser Support must be selected for this option. Uses 2 20 x 25 x 2 inch filters and 1 16 x 25 x 2 inch filters.
Show parts
Lookup Part! Ship Modules Separate Ship Modules Separate Option for Modular Units
Lookup Part! MB2-TOPRN Top Return Option for Size 2 Mixing Box - No Filter Option Available. Use top return lid and standard DF base.
Show parts
Lookup Part! FIRESTAT-DISCHARGE Discharge Firestat for Heaters Set to 240°F - Old Controls
Show parts
Lookup Part! FRSTAT-10 Freezestat With 10' Sensor. Factory set at 35°F and 10 minutes.
Show parts
Lookup Part! FRSTAT-LTL Freezestat With 10' Sensor and Low Temp Light on Remote Panel. Factory set at 35°F and 10 minutes.
Show parts
Lookup Part! FRSTAT-365 Day Freezestat With 10' Sensor and Low Temp Indicator on 365 Day Stat. Factory set at 35°F and 10 minutes.
Show parts
Lookup Part! FIRESTAT-INTAKE Intake Firestat for Heaters Set to 135°F - Old Controls
Show parts
Lookup Part! CCUTP2 Upturn Plenum for Size 2 Cooling Coil Module - Required for Up Discharge Cooling Coil Applications
Show parts
Lookup Part! VBI-CSF "Insulation" for V-bank Intake Option.
Lookup Part! VB-DS-MB2 V-bank Downstream of Mixing-Box Option Size 2
Lookup Part! DCVWP-SUPPLY Separate 120VAC Wiring Package for Make-Up Air Units. Option must be selected when mounting VFD in prewire panel or with DCV package. Provides separate 120VAC input to supply fan. This 120V signal must be run by electrician from DCV to mua switch.
Show parts
Lookup Part! VAV-WP-VDC-INPUT-MUA VAV (Variable-Air-Volume) Wiring Package for Commercial Fans. 0-10VDC Speed Control Variable Frequency Drive Included
Lookup Part! VAV-WP-BSPC-MUA VAV (Variable-Air-Volume) Wiring Package for Commercial Fans. Building Static Pressure Variable Frequency Drive Control Included
Show parts
Lookup Part! VAV-WP-BSPC VAV (Variable-Air-Volume) Wiring Package for Commercial Fans. Building Static Pressure Variable Frequency Drive Control Included
Show parts
Lookup Part! VAV-WP-BSPC-PCBMUA VAV (Variable-Air-Volume) Wiring Package for Commercial Fans. Building Static Pressure Variable Frequency Drive Control Included-MUA Board
Show parts
Lookup Part! VAV-WP-DSPC-PCBMUA VAV (Variable-Air-Volume) Wiring Package for Commercial Fans. Duct Static Pressure Variable Frequency Drive Control Included- MUA Board
Show parts
Lookup Part! VAV-WP-MC VAV (Variable-Air-Volume) Wiring Package for Commercial Fans. Manual Speed Control Variable Frequency Drive Included
Lookup Part! VAV-WP-MC-MUA VAV (Variable-Air-Volume) Wiring Package for Commercial Fans. Manual Speed Control Variable Frequency Drive Included
Lookup Part! VAV-WP-PS VAV (Variable-Air-Volume) Wiring Package for Commercial Fans with Frequency Drive. Preset Speed or Speed Reference Variable Frequency Drive Input Field Wired
Lookup Part! VFDINUNIT VFD factory mounted and wired in unit control vestibule.