Rep Our Products

Are you interested in representing CaptiveAire and selling our products?
Please fill out the following form, and we will contact you soon.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

 
A1-16Z Parts
Motors, Pulleys, & Motor Specific Parts
Motor HP Phs Voltage FLA Shaft Frame Weight RPM Vendor
Lookup Part!  - 186725/A01–ECM-50-277-16 1.750 1 208-220-230-240-277 V 6.2-5.8-5.6-5.3-4.6 0.000" 49 lbs 2390 Ziehl - Abegg
ODP-ECM (Open Drip Proof Electronically Commutated Motor)  
Show parts
Lookup Part!  - 186725/A01–ECM-60-277-16 1.750 1 208-220-230-240-277 V 6.2-5.8-5.6-5.3-4.6 0.000" 49 lbs 2390 Ziehl - Abegg
ODP-ECM (Open Drip Proof Electronically Commutated Motor)  
Show parts
Lookup Part!  - 186728/A01–ECM-50-240-16 2.500 3 200-208-220-230-240 V 5.9-5.7-5.4-5.1-4.9 0.000" 55 lbs 2770 Ziehl - Abegg
ODP-ECM (Open Drip Proof Electronically Commutated Motor)  
Show parts
Lookup Part!  - 186728/A01–ECM-60-240-16 2.500 3 200-208-220-230-240 V 5.9-5.7-5.4-5.1-4.9 0.000" 55 lbs 2770 Ziehl - Abegg
ODP-ECM (Open Drip Proof Electronically Commutated Motor)  
Show parts
Lookup Part!  - 186727/A01-ECM-50-480-16 3.400 3 380/400/415/440/460/480 V 4/3.8/3.7/3.4/3.3/3.2 0.000" 49 lbs 3000 Ziehl - Abegg
ODP-ECM (Open Drip Proof Electronically Commutated Motor)  
Show parts
Lookup Part!  - 186727/A01-ECM-60-480-16 3.400 3 380/400/415/440/460/480 V 4/3.8/3.7/3.4/3.3/3.2 0.000" 49 lbs 3000 Ziehl - Abegg
ODP-ECM (Open Drip Proof Electronically Commutated Motor)  
Show parts

The manufacturer reserves the right to use alternate motors from alternate vendors that meet the operating requirements of the fan but may have slightly different specifications.
Intakes & Intake Parts
Part
Lookup Part! CD-VB-O-01M-HE Celdek and V-Bank for Size # 1 Modular Supply unit with HE filters. For outdoor installation. MERV 15 V-Bank Filters. Includes Screened Intake
Show parts
Lookup Part! CD-VB-O-01M-HE-IL Celdek and V-Bank for Size # 1 Modular Supply unit with HE filters. For outdoor installation. MERV 15 V-Bank Filters. Includes Intake Louver.
Show parts
Lookup Part! CD-VB-O-01M-HEPA Celdek and V-Bank for Size # 1 Modular Supply unit with HEPA filters. For outdoor installation. Includes Screened Intake
Show parts
Lookup Part! CD-VB-O-01M-HEPA-IL Celdek and V-Bank for Size # 1 Modular Supply unit with HEPA filters. For outdoor installation. Includes Intake Louver.
Show parts
Lookup Part! CD-VB-O-01M-TA Celdek and V-Bank for Size # 1 Modular Supply unit with TA filters. For outdoor installation. MERV 8 V-Bank Filters. Includes Screened Intake
Show parts
Lookup Part! CD-VB-I-01M-TA Celdek and V-Bank for Size # 1 Modular Supply unit with TA filters. For indoor installation. MERV 8 V-Bank Filters.
Show parts
Lookup Part! CD-VB-O-01M-TA-13-IL Celdek and V-Bank for Size # 1 Modular Supply unit with TA filters. For outdoor installation. MERV 13 V-Bank Filters. Includes Intake Louver.
Show parts
Lookup Part! CD-VB-O-01M-TA-IL Celdek and V-Bank for Size # 1 Modular Supply unit with TA filters. For outdoor installation. MERV 8 V-Bank Filters. Includes Intake Louver.
Show parts
Lookup Part! CD-VB-I-01M-TA-13 Celdek and V-Bank for Size # 1 Modular Supply unit with TA filters. For indoor installation. MERV 13 V-Bank Filters.
Show parts
Lookup Part! CD-VB-O-01M-TA-13 Celdek and V-Bank for Size # 1 Modular Supply unit with TA filters. For outdoor installation. MERV 13 V-Bank Filters. Includes Screened Intake
Show parts
Lookup Part! CD-VB-I-01M Celdek and V-Bank for Size # 1 Modular Supply unit. For indoor installation.
Show parts
Lookup Part! CD-VB-O-01M Celdek and V-Bank for Size # 1 Modular Supply unit. For outdoor installation. Includes Screened Intake
Show parts
Lookup Part! CD-VB-O-01M-IL Celdek and V-Bank for Size # 1 Modular Supply unit. For outdoor installation. Includes Intake Louver.
Show parts
Lookup Part! CD-O A1-IH Celdek Evaporative Cooler for Size # 1 Modular Un-tempered Supply Air unit. 26.75" Wide X 76.438" Long X 29.688" High. Includes intake hood with filters. For outdoor installation. Use with water softener recommended.
Show parts
Lookup Part! CD-O A1 Celdek Evaporative Cooler for Size # 1 Modular Un-tempered Supply Air Unit. 26.75" Wide X 54.5" Long X 36.688" High. Includes screened intake. For outdoor installation.
Show parts
Lookup Part! CD-O A1-NF Celdek Evaporative Cooler for Size # 1 Modular Un-tempered Supply Air Unit. 26.75" Wide X 76.438" Long X 36.688" High. Includes intake hood without filters. For outdoor installation. Use with water softener recommended.
Show parts
Lookup Part! CD-O A1-IL Celdek Evaporative Cooler for Size # 1 Modular Un-tempered Supply Air Unit. 26.75" Wide X 54.5" Long X 36.688" High. Includes intake louver. For outdoor installation.
Show parts
Lookup Part! CD-I A1 Celdek Evaporative Cooler for Size # 1 Modular Un-tempered Supply Air unit. 26.75" Wide X 32.125" Long X 29.688" High. For indoor installation. Min. water pressure for optimal performance is 30 PSI. Max. water pressure should not exceed 50 PSI. Use with water softener recommended.
Show parts
Lookup Part! SI-1 Screen Intake for Size 1 Commercial Fans.
Show parts
Lookup Part! CD-O A2-NF-1 Size # 2 Celdek Evaporative Cooler for Size # 1 Modular Un-tempered Supply Air unit. 36.75" Wide X 85.813" Long X 36.688" High. Includes intake hood without filters. For outdoor installation. Use with water softener recommended.
Show parts
Lookup Part! CD-TL-O A2-1 Size # 2 Celdek Evaporative Cooler for Size # 1 Modular Un-tempered Supply Air Unit. 36.75" Wide X 142.438" Long X 36.688" High. Includes duct extension and screened intake. For outdoor installation. Use with water softener recommended.
Show parts
Lookup Part! CD-O A2-IH-1 Size # 2 Celdek Evaporative Cooler for Size # 1 Modular Un-tempered Supply Air unit. 36.75" Wide X 85.813" Long X 36.688" High. Includes intake hood with filters. For outdoor installation. Use with water softener recommended.
Show parts
Lookup Part! CD-O A2-1 Size # 2 Celdek Evaporative Cooler for Size # 1 Modular Un-tempered Supply Air Unit. ~ 36.75" Wide X 62.438" Long X 36.688" High. Includes screened intake. For outdoor installation. Use with water softener recommended.
Show parts
Lookup Part! CD-I A2-1 Size 2 Celdek Evaporative Cooler for Size # 1 Modular Un-tempered Supply Air unit. 36.75" Wide X 32.125" Long X 36.688" High. For indoor installation. Min. water pressure for optimal performance is 30 PSI. Max. water pressure should not exceed 50 PSI. Use with water softener recommended.
Show parts
Lookup Part! CD-LPD-VB-I-02-1M-TA-13 Size 2 LPD Celdek and V-Bank for Size # 1 Modular Supply unit. For indoor installation.
Show parts
Lookup Part! CD-LPD-VB-I-02-1M-TA Size 2 LPD Celdek and V-Bank for Size # 1 Modular Supply unit. For indoor installation.
Show parts
Lookup Part! CD-LPD-VB-I-02-1M Size 2 LPD Celdek and V-Bank for Size # 1 Modular Supply unit. For indoor installation.
Show parts
Lookup Part! CD-LPD-VB-I-02-1M-HEPA Size 2 LPD Celdek and V-Bank for Size # 1 Modular Supply unit. For indoor installation.
Show parts
Lookup Part! CD-LPD-VB-I-02-1M-HE Size 2 LPD Celdek and V-Bank for Size # 1 Modular Supply unit. For indoor installation.
Show parts
Lookup Part! CD-LPD-VB-O-02-1M-HE Size 2 LPD Celdek and V-Bank for Size # 1 Modular Supply unit. For outdoor installation. Includes Screened Intake
Show parts
Lookup Part! CD-LPD-VB-O-02-1M-HEPA Size 2 LPD Celdek and V-Bank for Size # 1 Modular Supply unit. For outdoor installation. Includes Screened Intake
Show parts
Lookup Part! CD-LPD-VB-O-02-1M Size 2 LPD Celdek and V-Bank for Size # 1 Modular Supply unit. For outdoor installation. Includes Screened Intake
Show parts
Lookup Part! CD-LPD-VB-O-02-1M-TA Size 2 LPD Celdek and V-Bank for Size # 1 Modular Supply unit. For outdoor installation. Includes Screened Intake
Show parts
Lookup Part! CD-LPD-VB-O-02-1M-TA-13 Size 2 LPD Celdek and V-Bank for Size # 1 Modular Supply unit. For outdoor installation. Includes Screened Intake
Show parts
Lookup Part! CD-LPD-VB-O-02-1M-IL Size 2 LPD Celdek and V-Bank for Size # 1 Modular Supply unit. For outdoor installation. Includes Intake Louver.
Show parts
Lookup Part! CD-LPD-VB-O-02-1M-HE-IL Size 2 LPD Celdek and V-Bank for Size # 1 Modular Supply unit. For outdoor installation. Includes Intake Louver.
Show parts
Lookup Part! CD-LPD-VB-O-02-1M-HEPA-IL Size 2 LPD Celdek and V-Bank for Size # 1 Modular Supply unit. For outdoor installation. Includes Intake Louver.
Show parts
Lookup Part! CD-LPD-VB-O-02-1M-TA-IL Size 2 LPD Celdek and V-Bank for Size # 1 Modular Supply unit. For outdoor installation. Includes Intake Louver.
Show parts
Lookup Part! CD-LPD-VB-O-02-1M-TA-13-IL Size 2 LPD Celdek and V-Bank for Size # 1 Modular Supply unit. For outdoor installation. Includes Intake Louver.
Show parts
Lookup Part! SFIH-01M Sloped Filtered Intake for Size #1 Modular Untempered Supply Unit. 21.813" Wide x 44.375" Long x 23.375" High. Includes 2" MV EZ Kleen Metal Mesh Filters.
Show parts
Lookup Part! SFIH-01S Sloped Filtered Intake for Size #1 Standard Untempered Supply Unit. 22" Wide x 25.875" Long x 23.375" High. Includes 2" MV EZ Kleen Metal Mesh Filters.
Show parts
Lookup Part! TL-01M TRUNKLINE - Extended Intake for size 1, modular untempered MUA unit, 19.75" Width, 132.32" Length, 21.32" Height Includes intake hood with 2" EZ Kleen metal mesh filters, adjustable legs and 87.75" long extension.
Show parts
Lookup Part! TL-01S TRUNKLINE - Extended Intake for size 1, standard untempered MUA unit, 19.75" Width, 114" Length, 21.32" Height Includes intake hood with 2" EZ Kleen metal mesh filters, and 87.75" long extension.
Show parts
Lookup Part! VB-O-01M-HE-IL V-Bank for Size # 1 Modular Make-Up Air unit with HE Filters. Includes intake louver. For outdoor installation. MERV 15 V-Bank Filters.
Show parts
Lookup Part! VB-O-01M-HEPA-IL V-Bank for Size # 1 Modular Make-Up Air unit with HEPA filters. Includes intake louver. For outdoor installation.
Show parts
Lookup Part! VB-O-01M-TA-13-IL V-Bank for Size # 1 Modular Make-Up Air unit with TA Filters. Includes intake louver. For outdoor installation. MERV 13 V-Bank Filters
Show parts
Lookup Part! VB-O-01M-TA-IL V-Bank for Size # 1 Modular Make-Up Air unit with TA Filters. Includes intake louver. For outdoor installation. MERV 8 V-Bank Filters.
Show parts
Lookup Part! VB-O-01M-IL V-Bank for Size # 1 Modular Make-Up Air unit. EZ Metal Mesh Filters. Includes intake louver. For outdoor installation.
Show parts
Lookup Part! VB-I-01M-HE V-Bank for Size # 1 Modular Supply unit with HE filters. For indoor installation. MERV 15 V-Bank Filters.
Show parts
Lookup Part! VB-I-01M-HEPA V-Bank for Size # 1 Modular Supply unit with HEPA filters. For indoor installation.
Show parts
Lookup Part! VB-I-01M-TA V-Bank for Size # 1 Modular Supply unit with TA filters. For indoor installation. MERV 8 V-Bank Filters.
Show parts
Lookup Part! VB-I-01M-TA-13 V-Bank for Size # 1 Modular Supply unit with TA filters. For indoor installation. MERV 13 V-Bank Filters.
Show parts
Lookup Part! VB-I-01M V-Bank for Size # 1 Modular Supply unit. EZ Metal Mesh Filters. For indoor installation.
Show parts
Lookup Part! VB-O-01M-TA-13-IH-EZ V-Bank for Size #1 Modular Indirect-Fired Heater with TA Filters. Includes intake hood with EZ filters. For outdoor installation. MERV 13 V-Bank Filters.
Show parts
Lookup Part! VB-O-01M-HE V-Bank for Size #1 Modular Make-Up Air unit with HE Filters. Includes and screened intake. For outdoor installation. MERV 15 V-Bank Filters.
Show parts
Lookup Part! VB-O-01M-HE-IH-EZ V-Bank for Size #1 Modular Make-Up Air unit with HE Filters. Includes intake hood with EZ filters. For outdoor installation. MERV 15 V-Bank Filters.
Show parts
Lookup Part! VB-O-01M-HEPA V-Bank for Size #1 Modular Make-Up Air unit with HEPA filters. Includes and screened intake. For outdoor installation.
Show parts
Lookup Part! VB-O-01M-HEPA-IH-EZ V-Bank for Size #1 Modular Make-Up Air unit with HEPA filters. Includes intake hood with EZ filters. For outdoor installation.
Show parts
Lookup Part! VB-O-01M-TA V-Bank for Size #1 Modular Make-Up Air unit with TA Filters. Includes and screened intake. For outdoor installation. MERV 8 V-Bank Filters.
Show parts
Lookup Part! VB-I-01M-TA-13 V-Bank for Size #1 Modular Make-Up Air unit with TA Filters. Includes screened intake. For indoor installation. MERV 13 V-Bank Filters.
Show parts
Lookup Part! VB-O-01M-TA-13 V-Bank for Size #1 Modular Make-Up Air unit with TA Filters. Includes screened intake. For outdoor installation. MERV 13 V-Bank Filters.
Show parts
Lookup Part! VB-O-01M V-Bank for Size #1 Modular Make-Up Air unit. EZ Metal Mesh Filters. Includes screened intake. For outdoor installation.
Show parts
Lookup Part! VB-O-01M-TA-EZ V-Bank for Size #1 with TA Filters. Includes intake hood with EZ filters. For outdoor installation. MERV 8 V-Bank Filters.
Show parts
Replacement Parts
Part
Lookup Part!  - [4 used] 33008 A0003208 - 3/8" WASHERS
Lookup Part!  - [3 used] 8003 CONDUIT CONNECTOR - 90deg; 1/2" Bridgeport, 1/2" long thread
Lookup Part!  - [4 used] MLIFTL LIFTING LUG
Lookup Part!  - [8 used] 0120763.0800 A0031100 - 1"L, 1/4-20 Matpoint, Self Aligning, Hex Head, Grade 5 Bolt
Lookup Part!  - [8 used] 11626-03224 Cage Nut - 1/4" - 20. Installed in 1/2" square hole. Used on 20 gauge material.
Lookup Part!  - [8 used] 5/16-18 WHIZNUT Zinc-Plated Grade 5 Steel Serrated-Flange Locknut, 5/16"-18 Thread Size, 11/16" Flange Diameter, 9/32" Overall Height.
Lookup Part!  - [8 used] 8002 CONDUIT - 1/2" LT FLEX JIC. (Price per Foot)
Lookup Part!  - [1 used] DUCTBOARD DUCTBOARD 4X10 SHEET Owens Corning Type 475FRK Insulation. 1 Sheet.
Lookup Part!  - [2 used] 800041 Bolt Whiz 10-32 X 1/2, SFB103212Z, Steel Grade 5 Minimum (3 Evenly Spaced Radial Marks)
Lookup Part!  - [2 used] 800030 Nut Whiz 10-32, SFLN1032Z, Steel, Large Flange
Lookup Part!  - [1 used] 3M467J Captiveaire Factory Direct sticker
Lookup Part!  - [4 used] HG-OTA100 Removable Door Hinge used on Pollution Control Units and KB Blowers
Lookup Part!  - [4 used] SCREW 10-24X3/8 ZINC RD HD SLOTTED MS - DOOR HANDLE SCREW 10-24X3/8 ZINC RD HD SLOTTED MS - Used on UC door handles and MUA door handles
Lookup Part!  - [1 used] 104778 SEALANT - 10.3 oz Silicone Silver/Aluminum Sealant. 350 deg silicone used in hoods. (item #104778)
Lookup Part!  - [1 used] MANUAL UNTEMP Manual for Commercial Supply Fan
Lookup Part!  - [2 used] A7-10-351-20 Black Compression Handle Latch and Clasp
Lookup Part!  - [104 used] SB6-4-RIVET RIVET - 3/16" Diameter, .126 To .250 Grip Range, SB6-4 Button Head Steel/Steel. Replaced 800075.
Lookup Part!  - [10 used] ITH41234 SHEET METAL SCREWS 12-14 X 3/4"
Lookup Part!  - [2 used] M1EFLS 1 END FLASHING
Lookup Part!  - [1 used] B1DDBAVP1618Z A1 Direct Drive Blower Assembly Venturi Assembly Ziehl
Lookup Part!  - [1 used] B1DDCZ A1 Direct Drive Collar Ziehl
Lookup Part!  - [1 used] B1DDDDLZ A1 Direct Drive Down Discharge Liner Ziehl
Lookup Part!  - [1 used] B1DDWGZ A1 Direct Drive Wheel Guard Ziehl
Lookup Part!  - [1 used] B1DDC AHU 1 Direct Drive Discharge Collar
Lookup Part!  - [1 used] B1LIDDPRL AHU 1 LID w/Intergrated Drip Rail
Lookup Part!  - [1 used] B1SDBKHDD AHU 1 Side Discharge Back Hinged Direct Drive
Lookup Part!  - [2 used] ME12MR EC 1-2 MAIN RAIL 35.25X8 GALV14GA. Also used on Size 1 Blower.
Lookup Part!  - [3 used] M1HSUP HORIZONTAL SUPPORT
Lookup Part!  - [4 used] L1VIB Motor Frame Vibration Eliminator 1" Out. Dia. X 1/4" Tall, Rubber (Black) New Style, 5/16-18 x 1/2 dual studs. Durometer = 50
Curbs
Part
Lookup Part! CRB21X7H ROOF CURB - 21" Square X 7" High
Lookup Part! CRB21X8 ROOF CURB - 21" Square X 8" High
Lookup Part! CRB21X12 ROOF CURB - 21" Square X 12" High
Lookup Part! CRB21X14 ROOF CURB - 21" Square X 14" High
Lookup Part! CRB21X15 ROOF CURB - 21" Square X 15" High
Lookup Part! CRB21X16 ROOF CURB - 21" Square X 16" High
Lookup Part! CRB21X20-BTC BOLT TOGETHER ROOF CURB -21" Square X 20" High, 18 GA Galvanized. Ships Flat. Pitched Curb Option Not Available with Bolt Together Curbs.
Lookup Part! CRB21X20 ROOF CURB - 21" Square X 20" High
Lookup Part! CRB21.0X22.5H ROOF CURB - 21.0" Square X 22.5" High
Lookup Part! CRB21X26 CURB - 21" Square X 26" High
Lookup Part! CRB21X30 ROOF CURB - 21" Square X 30" High
Lookup Part! CRB21X42 ROOF CURB - 21" Square X 42" High
Options
Parts
Lookup Part! D4120-DST-1.5-C Duct Mounted Smoke Detector For Commercial Direct Fired Heater. Complete with detector (D4120) and sampling tube (DST-1.5). Ships Loose
Show parts
Lookup Part! CWCM1-2 CW Coil Module for Size 1 Modular Fans - 1,000 thru 3,250 CFM (5 Ton, 5WS1004B-31.5x27.0) Not stocked. Allow 5-6 weeks lead time. Temperature controls, mixing valves, thermostats, and freeze protection by others.
Show parts
Lookup Part! CWCM1-4 CW Coil Module for Size 1 Modular Fans - 1,000 thru 3,250 CFM (12.5 Ton, 5WS1404B-31.5x27.0) Not stocked. Allow 5-6 weeks lead time. Temperature controls, mixing valves, thermostats, and freeze protection by others.
Show parts
Lookup Part! Ecoat-AC-1 Size 1 Cooling Coil Ecoating option for MPU-AC options. Adds 5-6 week lead time.
Lookup Part! Ecoat-1-MPU-RH Size 1 Cooling Coil Ecoating option for MPU-RH options. Adds 5-6 week lead time.
Lookup Part! Ecoat-1-C Size 1 Cooling Coil Ecoating option for standard MPU, DX and Chilled Water Coils. Adds 5-6 week lead time.
Lookup Part! Ecoat-1-H Size 1 Heating Coil Ecoating option for standard Hot Water and Steam Coils. Adds 5-6 week lead time.
Lookup Part! 3 Ton 1 Phase 208/230V Condensing Package 3 Ton, Single Circuit Condensing Unit. 1 phase 208-230V. Air Cooled. Includes: Disconnect Switch. R410A refrigerant and piping by others. 24ACC436A003
Show parts
Lookup Part! 3 Ton 208/230V Condensing Package 3 Ton, Single Circuit Condensing Unit. 3 phase 208/230V. Air Cooled. Includes: Disconnect Switch. R410A refrigerant and piping by others. Shipping included in price. 24ABB336A005
Show parts
Lookup Part! 3 Ton 460V Condensing Package 3 Ton, Single Circuit Condensing Unit. 3 phase 460V. Air Cooled. Includes: Disconnect Switch. R410A refrigerant and piping by others. 24ABB336A006
Show parts
Lookup Part! 3 Ton 575V Condensing Package 3 Ton, Single Circuit Condensing Unit. 3 phase 575V. Air Cooled. Includes: Disconnect Switch. R410A refrigerant and piping by others. 24ABB336A001
Show parts
Lookup Part! 5 Ton 1 Phase 208/230V Condensing Package 5 Ton, Single Circuit Condensing Unit. 1 phase 208-230V. Air Cooled. Includes: Disconnect Switch. R410A refrigerant and piping by others. 24ABB360A003
Show parts
Lookup Part! 5 Ton 208/230V Condensing Package 5 Ton, Single Circuit Condensing Unit. 3 phase 208/230V. Air Cooled. Includes: Disconnect Switch. R410A refrigerant and piping by others. 24ABB360A005
Show parts
Lookup Part! 5 Ton 460V Condensing Package 5 Ton, Single Circuit Condensing Unit. 3 phase 460V. Air Cooled. Includes: Disconnect Switch. R410A refrigerant and piping by others. 24ABB360A006
Show parts
Lookup Part! A10SDAD-A 180° Side Discharge Air Diffuser A10, A12, A15. For Commercial Heaters.
Lookup Part! A10DDAD3W-A 3-Way Down Discharge Air Diffuser A10, A12, A15. For Commercial Fans.
Show parts
Lookup Part! A10DDAD4W-A 4-Way Down Discharge Air Diffuser A10, A12, A15. For Commercial Fans.
Show parts
Lookup Part! A10DDAD-A 45° Down Discharge Air Diffuser A10, A12, A15. For Commercial Fans.
Lookup Part! DXM1-3 DX Coil Module for Size 1 Modular Fans - 2,000 thru 3,250 CFM (10 Ton - 2 Circuit DX Coil, 4EZ0903H-31.5x27.0) NOT BUILT WITH OPP SIDE CONTROLS. DXM1-3 Condenser and condenser disconnect (unless provided on quote) will be installed, started and warranted by others. R410A refrigerant and piping by others. Ensure DX-Kit is ordered for filter drier, sight glass, thermal expansion valve. (Old Heatcraft Coil # 5EJ0804B-31.5x27.0)
Show parts
Lookup Part! ECM Wiring Package- RTC (1PH-Ziehl) ECM Wiring Package and Manual or 0-10 VDC Control for Supply EC Single Phase Ziehl Fans. RTC Controller
Show parts
Lookup Part! ECM Wiring Package- RTC (Ziehl) ECM Wiring Package and Manual or 0-10 VDC Control for Supply EC Ziehl Fans. RTC Controller
Show parts
Lookup Part! ECM Wiring Package - MSC (1PH-Ziehl) ECM Wiring Package and Manual or 0-10 VDC Control for Supply EC Single Phase Ziehl Fans. MSC Controller
Show parts
Lookup Part! ECM Wiring Package - MSC (Ziehl) ECM Wiring Package and Manual or 0-10 VDC Control for Supply EC Ziehl Fans. MSC Controller
Show parts
Lookup Part! ECM Wiring Package- ECPM03 (1PH-Ziehl) ECM Wiring Package-Supply - PWM Signal from ECPMO3 Prewire (1 - Phase Ziehl Motor)
Show parts
Lookup Part! ECM Wiring Package- ECPM03 (Ziehl) ECM Wiring Package-Supply - PWM Signal from ECPMO3 Prewire (3 - Phase Ziehl Motor)
Show parts
Lookup Part! EC-FPDK-Evap Freeze Protection Drain Control kit for Evaporative Coolers. Includes 3-Way water solenoid valve 8316G064 (shipped loose), Pressure switch installed upstream of 2way solenoid in unit, Brass Tee, 2 NPT half inch nipples, and two stage thermostat T678A1361. Field wiring required by others for 3-way valve. For both Celdek and Standard V-bank type Configurations.
Show parts
Lookup Part! CD-G-24x20x12 Glasdek Media for size 1 celdek evaporative cooler intake. 24in wide x 20in tall x 12in thick.
Lookup Part! CD-G-32x25x12 Glasdek Media for size 2 celdek evaporative cooler intake. 32in wide x 25in tall x 12in thick.
Lookup Part! UFEC 120V Wiring connection to energize evaporative coolers from untempered supply fans.
Lookup Part! MIAMI-DADE NOA-2 Supply Miami Dade Impact and Wind Load Certification +30 / -130 PSF - Miami Dade County Product Control Approved. Florida Building Code approval. Roof Mount Exhaust Curbs up to 20" high must be 18 gauge Aluminized.
Lookup Part! 5181 Gravity Back Draft Damper, 16" wide x 18" high, Standard Galvanized Construction, 1 1/4" Rear Flange, for Size 1 Untempered Fan Housing (5181)
Lookup Part! HWCM1 Hot Water Coil Module for Size 1 Modular Fans - 3350 CFM @ 70deg Temp Rise (253,260 BTU's) Coil = 5MS1402B-19.5x16.5. Opposite airflow requires special order coil with extended lead-time. Temperature controls, mixing valves, thermostats, and freeze protection by others.
Show parts
Lookup Part! IHC-MUA1 Indoor Hanging Cradle For The Size 1 Untempered Unit. 2 HSA125 Hanging Isolators per Uni-Strut Included.
Show parts
Lookup Part! ADD_STARTER Adds a starter for untempered MPUs.
Lookup Part! OPPSIDE-S-CTRLS Mount motor and disconnect on opposite side of fan.
Lookup Part! 6 Pole Rotary Disconnect 6 Pole 40 Amp Rotary Disconnect for Fans. Includes Switch, switch handle, mounting plate, gasket, and junction box.
Show parts
Lookup Part! CVOUTLET GFCI 15 amp Convenience Outlet For Heater Enclosure. Power supply by others - Includes receptacle and J box.
Lookup Part! CT-CC DX Cooling Intake Air Thermostat - Ships Loose with Untempered fan - Set Point For Thermostat Should Be 85°F. Do Not Use When Cooling Option is in Pre-Wire Package.
Show parts
Lookup Part! EXTENDED-DROP Extended Drop for Commercial Heaters and Supply Fans. Extends the power and remote panel connections to the unit to 20' of total length.
Lookup Part! Single Electrical Cabinet LED Lights Single Electrical Cabinet LED Lights Used on Modular MUA Units
Show parts
Lookup Part! MB1-MPU Support shell for Size 1 Modular Package Unit. Includes control vestibule. Includes condenser supports. Does not include return air or inlet air damper.
Show parts
Lookup Part! MB1-NC Mixing Box for Size 1 Modular Supply Fan. Actuator and Controls provided by others.
Show parts
Lookup Part! MB1-SP Mixing Box for Size 1 Modular Supply Fan. Actuator Control by Static Pressure. Photohelic included.
Show parts
Lookup Part! MB1-Manual-0-10V Mixing Box for Size 1 Modular Supply Fan. Actuator Controlled by Manual 0-10V Signal from RTUlink-ACHP board.
Show parts
Lookup Part! MB1-MP Mixing Box for Size 1 Modular Supply Fan. Actuator Control by Manual Potentiometer. Manual Potenentiometer included.
Show parts
Lookup Part! MB1-TP Mixing Box for Size 1 Modular Supply Fan. 2-Position Actuator Control. Interlock field wired by others. Spring Return to Outside Air Position.
Show parts
Lookup Part! MPU1-2-208-1 2 Ton, Single Circuit Modular Packaged Cooling Option for Size 1 Modular Packaged Unit. Includes Condenser, DX Coil, Filter/Dryer Kit, Hard Start Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (1,000 to 1,200 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 208V, 1 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 2EZ0801M
Show parts
Lookup Part! MPU1-3-208-1 3 Ton, Single Circuit Modular Packaged Cooling Option for Size 1 Modular Packaged Unit. Includes Condenser, DX Coil, Filter/Dryer Kit, Hard Start Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (1,100 to 1,800 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 208V, 1 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 2EZ1001N
Show parts
Lookup Part! MPU1-3-208-3 3 Ton, Single Circuit Modular Packaged Cooling Option for Size 1 Modular Packaged Unit. Includes Condenser, DX Coil, Filter/Dryer Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (1,100 to 1,800 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 208V, 3 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 2EZ1001N
Show parts
Lookup Part! MPU1-3-460-3 3 Ton, Single Circuit Modular Packaged Cooling Option for Size 1 Modular Packaged Unit. Includes Condenser, DX Coil, Filter/Dryer Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (1,100 to 1,800 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 460V, 3 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 2EZ1001N
Show parts
Lookup Part! MPU1-3-575-3 3 Ton, Single Circuit Modular Packaged Cooling Option for Size 1 Modular Packaged Unit. Includes Condenser, DX Coil, Filter/Dryer Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (1,100 to 1,800 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 575V, 3 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 2EZ1001N
Show parts
Lookup Part! MPU1-5E-208-3 5 Ton, Dual Circuit (2.5/2.5) Modular Packaged Cooling Option for Size 1 Modular Packaged Unit. Includes Condenser, DX Coil, Filter/Dryer Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (1,800 to 3,000 cfm) NOT BUILT WITH OPPOSITE SIDE CONTROLS OR OPPOSITE AIRFLOW DIRECTION. CONDENSERS REQUIRE SEPARATE 208V, 3 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 2EZ0902ME
Show parts
Lookup Part! MPU1-5-208-1 5 Ton, Dual Circuit (2/3) Modular Packaged Cooling Option for Size 1 Modular Packaged Unit. Includes Condenser, DX Coil, Filter/Dryer Kit, Hard Start Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (1,800 to 3,000 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 208V, 1 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 2EZ0902M
Show parts
Lookup Part! MPU1-2-AC-208-1 2 Ton, Single Circuit Modular Packaged AC Cooling Option for Size 1 Modular Packaged Unit. Includes Condenser, DX Coil, Filter/Dryer Kit, Hard Start Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (450 to 1200 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 208V, 1 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 2Ey1102E
Show parts
Lookup Part! MPU1-3-AC-208-1 3 Ton, Single Circuit Modular Packaged AC Cooling Option for Size 1 Modular Packaged Unit. Includes Condenser, DX Coil, Filter/Dryer Kit, Hard Start Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (450 to 1225 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 208V, 1 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 2EY1402E
Show parts
Lookup Part! MPU1-3-AC-208-3 3 Ton, Single Circuit Modular Packaged AC Cooling Option for Size 1 Modular Packaged Unit. Includes Condenser, DX Coil, Filter/Dryer Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (450 to 1,225 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 208V, 3 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 2EY1402
Show parts
Lookup Part! MPU1-3-AC-460-3 3 Ton, Single Circuit Modular Packaged AC Cooling Option for Size 1 Modular Packaged Unit. Includes Condenser, DX Coil, Filter/Dryer Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (450 to 1,225 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 460V, 3 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 2EY1402E
Show parts
Lookup Part! MPU1-5E-AC-208-3 5 Ton, Dual Circuit (2.5/2.5) Modular Packaged AC Cooling Option for Size 1 Modular Packaged Unit. Includes Condenser, DX Coil, Filter/Dryer Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (750 to 1,350 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 208V, 3 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 2EY1403
Show parts
Lookup Part! MPU1-5-AC-208-1 5 Ton, Dual Circuit (2/3) Modular Packaged AC Cooling Option for Size 1 Modular Packaged Unit. Includes Condenser, DX Coil, Filter/Dryer Kit, Hard Start Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (750 to 1,350 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 208V, 1 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 2EY1403E
Show parts
Lookup Part! MPU1-2-AC-HP-208-1 2 Ton, Single Circuit Modular Packaged AC Cooling Option with Heat Pump for Size 1 Modular Packaged Unit. Includes Heat Pump, DX Coil, Filter/Dryer Kit, Hard Start Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (450 to 1200 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 208V, 1 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 2Ey1102E
Show parts
Lookup Part! MPU1-3-AC-HP-208-1 3 Ton, Single Circuit Modular Packaged AC Cooling Option with Heat Pump for Size 1 Modular Packaged Unit. Includes Heat Pump, DX Coil, Filter/Dryer Kit, Hard Start Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (450 to 1225 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 208V, 1 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 2EY1402E
Show parts
Lookup Part! MPU1-3-AC-HP-208-3 3 Ton, Single Circuit Modular Packaged AC Cooling Option with Heat Pump for Size 1 Modular Packaged Unit. Includes Heat Pump, DX Coil, Filter/Dryer Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (450 to 1,225 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 208V, 3 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 2EY1402
Show parts
Lookup Part! MPU1-3-AC-HP-460-3 3 Ton, Single Circuit Modular Packaged AC Cooling Option with Heat Pump for Size 1 Modular Packaged Unit. Includes Heat Pump, DX Coil, Filter/Dryer Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (450 to 1,225 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 460V, 3 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 2EY1402E
Show parts
Lookup Part! MPU1-2-208-1-HP 2 Ton, Single Circuit Modular Packaged Cooling Option with heat pump for Size 1 Modular Packaged Unit. Includes Heat Pump, DX Coil, Filter/Dryer Kit, Hard Start Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (1,000 to 1,200 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 208V, 1 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 2EZ0801M
Show parts
Lookup Part! MPU1-3-208-1-HP 3 Ton, Single Circuit Modular Packaged Cooling Option with heat pump for Size 1 Modular Packaged Unit. Includes Heat Pump, DX Coil, Filter/Dryer Kit, Hard Start Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (1,100 to 1,800 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 208V, 1 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 2EZ1001N
Show parts
Lookup Part! MPU1-3-208-3-HP 3 Ton, Single Circuit Modular Packaged Cooling Option with Heat Pump for Size 1 Modular Packaged Unit. Includes Heat Pump, DX Coil, Filter/Dryer Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (1,100 to 1,800 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 208V, 3 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 2EZ1001N
Show parts
Lookup Part! MPU1-3-460-3-HP 3 Ton, Single Circuit Modular Packaged Cooling Option with heat pump for Size 1 Modular Packaged Unit. Includes Heat Pump, DX Coil, Filter/Dryer Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (1,100 to 1,800 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 460V, 3 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 2EZ1001N
Show parts
Lookup Part! A1UPDISCH-DD Up Discharge Construction for Direct Drive AHUs
Show parts
Lookup Part! A1-U-MBDD Motorized Back Draft Damper 16" X 18" for Size 1 Untempered Units w/Extended Shaft, Standard Galvanized Construction, 3/4" Rear Flange, Low Leakage, TFB120S Actuator Included
Show parts
Lookup Part! A1-MBDD-SL Motorized Back Draft Discharge Damper Shipped Loose 22.75" X 24" for Size 1 Units w/Extended Shaft, Standard Galvanized Construction, 3/4" Rear Flange, Low Leakage, LF120-S Actuator Included, Field Installation Required. Damper, actuator & actuator cover (p/n ACTCOVERMOD) factory assembled.
Show parts
Lookup Part! Full Crating for Untempered Fan Full crating for untempered fans for shipping.
Lookup Part! SPO10-Enamel Tan Enamel Coating For 10" or smaller Fan. Consult factory for other colors. Sherwin Williams p/n F75KXN5809-4347, (AX = A0006229)
Lookup Part! Condenser_Locking_Caps_2 Locking caps for double condenser units. Consists of 4 locking caps, part# NCP-4, and 1 key, part# NC-KEY.
Show parts
Lookup Part! Condenser_Locking_Caps_1 Locking caps for single condenser units. Consists of 2 locking caps, part# NCP-4, and 1 key, part# NC-KEY.
Show parts
Lookup Part! HP_Condenser_Locking_Caps_1 Locking caps for single heat pump condenser units. Consists of 3 locking caps, part# NCP-4, and 1 key, part# NC-KEY.
Show parts
Lookup Part! DX 1-1 KIT-R410A DX 1-1 Kit R410A. Single Circuit, 3 Ton. Includes Filter Drier, Sight Glass, and Thermal Expansion Valve for DX units. Installation by others. Includes R410A TXV. Installation by others. Includes R410A TXV.
Show parts
Lookup Part! DX 1-2 KIT-R410A DX 1-2 Kit R410A. Single Circuit 5 Ton. Includes Filter Drier, Sight Glass, and Thermal Expansion Valve for DX units. Installation by others. Includes R410A TXV. Installation by others. Includes R410A TXV.
Show parts
Lookup Part! DX 1-3 KIT-R410A DX 1-3 Kit R410A. Dual Circuit 10 Ton. Includes Filter Drier, Sight Glass, and Thermal Expansion Valve for DX units. Installation by others. Includes R410A TXV. Installation by others. Includes R410A TXV.
Show parts
Lookup Part! DX 1-4 KIT-R410A DX 1-4 Kit R410A. Dual Circuit 12.5 Ton. Includes Filter Drier, Sight Glass, and Thermal Expansion Valve for DX units. Installation by others. Includes R410A TXV. Installation by others. Includes R410A TXV.
Show parts
Lookup Part! ShipLoose-1C-1PH Ship Condenser Loose - Single Condenser, Single Phase - Condenser Disconnect Shipped Loose. All piping and wiring between indoor and outdoor units by others.
Show parts
Lookup Part! ShipLoose-1C-3PH Ship Condenser Loose - Single Condenser, Three Phase - Condenser Disconnect Shipped Loose. All piping and wiring between indoor and outdoor units by others.
Show parts
Lookup Part! ShipLoose-2C-1PH Ship Condensers Loose - Two Condensers, Single Phase - Condenser Disconnects Shipped Loose. All piping and wiring between indoor and outdoor units by others.
Show parts
Lookup Part! ShipLoose-2C-3PH Ship Condensers Loose - Two Condensers, Three Phase - Condenser Disconnects Shipped Loose. All piping and wiring between indoor and outdoor units by others.
Show parts
Lookup Part! SP-MPU-1C Single Point MPU Connection, 1 Condenser.
Show parts
Lookup Part! SP-MPU-2C Single Point MPU Connection, 2 Condensers.
Show parts
Lookup Part! MELIM-1 Size 1 Moisture Eliminator Option for DX Coils, MPUs and Chilled Water Coils - allows cooling coil face velocity to increase to 650 fpm. Increases cooling coil max cfm to 3650 cfm.
Show parts
Lookup Part! MPU1-RH Size 1 MPU Reheat Option. Reheat uses warm liquid refrigerant. Reheat runs continuously in stage 1 circuit. Option should not be used if entering air dew point is below 65 degrees F. Nominal capacity 7.6 MBH. Increases max CFM to 1460.
Show parts
Lookup Part! MELIM-1-AC Size 1 MPU-AC Moisture Eliminator Option - allows cooling coil face velocity to increase to 650 fpm. Increases cooling coil max cfm to 1450 cfm.
Show parts
Lookup Part! MPU-AC CONTROL Control Package for Mod Package Unit Cooling Only Unit. Includes airflow proving switch, RTUlink-ACHP board and terminal blocks.
Show parts
Lookup Part! MPU-HP CONTROL Control Package for Mod Package Unit Heat Pump Unit. Includes airflow proving switch, RTUlink-ACHP board and terminal blocks.
Show parts
Lookup Part! SCM1 Steam Coil Module for Size 1 Modular Fans - 2,250 CFM @ 70deg Temp Rise (188,730 BTU's) Coil = 5JA0902B-19.5x16.5 Temperature controls, mixing valves, thermostats, and freeze protection by others.
Show parts
Lookup Part! D-Hanger Curb Duct Hanger - 1-1/4" Angle Iron Frame Welded to Curb to support standard size ductwork. Priced per curb. Only available when curb assembly is ordered.
Lookup Part! MB1-MERV 13-EXTRA Extra set of MERV 13 filters for Size 1 Mixing Box. Uses 5 10 x 16 x 2 inch filters.
Show parts
Lookup Part! MB1-MERV 8-EXTRA Extra set of MERV 8 filters for Size 1 Mixing Box. 5 10 x 16 x 2 inch filters.
Show parts
Lookup Part! MB1-MERV 13 MERV 13 filter option for Size 1 Mixing Box or Condenser Support. Mixing Box or Condenser Support must be selected for this option. Uses 5 10 x 16 x 2 inch filters.
Show parts
Lookup Part! MB1-MERV 8 MERV 8 filter option for Size 1 Mixing Box or Condenser Support. Mixing Box or Condenser Support must be selected for this option. Uses 5 10 x 16 x 2 inch filters.
Show parts
Lookup Part! MB1-TOPRN Top Return Option for Size 1 Mixing Box - No Filter Option Available. Use top return lid and standard DF base.
Show parts
Lookup Part! VBI-CSF "Insulation" for V-bank Intake Option.
Lookup Part! VB-DS-MB1 V-bank Downstream of Mixing-Box Option Size 1
Lookup Part! DCVWP-SUPPLY Separate 120VAC Wiring Package for Make-Up Air Units. Option must be selected when mounting VFD in prewire panel or with DCV package. Provides separate 120VAC input to supply fan. This 120V signal must be run by electrician from DCV to mua switch.
Show parts
Lookup Part! VFDINUNIT VFD factory mounted and wired in unit control vestibule.