A3-IBT-800-400-400-25Z Parts
Motors, Pulleys, & Motor Specific Parts
Motor HP Phs Voltage FLA Shaft Frame Weight RPM Vendor
Lookup Part!  - 186736/A01-ECM-50-480-25 4.800 3 460/480 V 5/4.7 0.000" 119 lbs 1580 Ziehl - Abegg
ODP-ECM (Open Drip Proof Electronically Commutated Motor)  
Show parts
Lookup Part!  - 186736/A01-ECM-60-480-25 4.800 3 460/480 V 5/4.7 0.000" 119 lbs 1580 Ziehl - Abegg
ODP-ECM (Open Drip Proof Electronically Commutated Motor)  
Show parts
Lookup Part!  - 186738/A01-ECM-50-240-25 4.800 3 200-208-220-230-240 V 12-11.5-10.9-10.4-10 0.000" 119 lbs 1580 Ziehl - Abegg
ODP-ECM (Open Drip Proof Electronically Commutated Motor)  
Show parts
Lookup Part!  - 186738/A01-ECM-60-240-25 4.800 3 200-208-220-230-240 V 12-11.5-10.9-10.4-10 0.000" 119 lbs 1580 Ziehl - Abegg
ODP-ECM (Open Drip Proof Electronically Commutated Motor)  
Show parts
Lookup Part!  - 186733/A01-ECM-50-480-25 7.250 3 380/400/415/440/460/480 V 8.8/8.4/8/7.6/7.3/7 0.000" 145 lbs 1840 Ziehl - Abegg
ODP-ECM (Open Drip Proof Electronically Commutated Motor)  
Show parts
Lookup Part!  - 186733/A01-ECM-60-480-25 7.250 3 380/400/415/440/460/480 V 8.8/8.4/8/7.6/7.3/7 0.000" 145 lbs 1840 Ziehl - Abegg
ODP-ECM (Open Drip Proof Electronically Commutated Motor)  
Show parts

The manufacturer reserves the right to use alternate motors from alternate vendors that meet the operating requirements of the fan but may have slightly different specifications.
Intakes & Intake Parts
Part
Lookup Part! CD-VB-I-03MIF-TA Celdek and V-Bank for Size # 3 Modular Indirect-Fired Heater with TA filters. For indoor installation. MERV 8 V-Bank Filters.
Show parts
Lookup Part! CD-VB-I-03MIF Celdek and V-Bank for Size # 3 Modular Indirect-Fired Heater. For indoor installation.
Show parts
Lookup Part! CD-VB-I-03MIF-TA-13 Celdek and V-Bank for Size # 3 Modular Indirect-Fired Heater with TA filters. For indoor installation. MERV 13 V-Bank Filters.
Show parts
Lookup Part! CD-VB-O-03M-HE Celdek and V-Bank for Size # 3 Modular Supply unit with HE filters. For outdoor installation. MERV 15 V-Bank Filters. Includes Screened Intake
Show parts
Lookup Part! CD-VB-O-03M-HE-IL Celdek and V-Bank for Size # 3 Modular Supply unit with HE filters. For outdoor installation. MERV 15 V-Bank Filters. Includes Intake Louver.
Show parts
Lookup Part! CD-VB-I-03M-HE Celdek and V-Bank for Size # 3 Modular Supply unit with HE filters. For indoor installation. MERV 15 V-Bank Filters.
Show parts
Lookup Part! CD-VB-O-03M-HEPA Celdek and V-Bank for Size # 3 Modular Supply unit with HEPA filters. For outdoor installation. Includes Screened Intake
Show parts
Lookup Part! CD-VB-O-03M-HEPA-IL Celdek and V-Bank for Size # 3 Modular Supply unit with HEPA filters. For outdoor installation. Includes Intake Louver.
Show parts
Lookup Part! CD-VB-I-03M-HEPA Celdek and V-Bank for Size # 3 Modular Supply unit with HEPA filters. For indoor installation.
Show parts
Lookup Part! CD-VB-O-03M-TA Celdek and V-Bank for Size # 3 Modular Supply unit with TA filters. For outdoor installation. MERV 8 V-Bank Filters. Includes Screened Intake
Show parts
Lookup Part! CD-VB-O-03M-TA-13-IL Celdek and V-Bank for Size # 3 Modular Supply unit with TA filters. For outdoor installation. MERV 13 V-Bank Filters. Includes Intake Louver.
Show parts
Lookup Part! CD-VB-O-03M-TA-IL Celdek and V-Bank for Size # 3 Modular Supply unit with TA filters. For outdoor installation. MERV 8 V-Bank Filters. Includes Intake Louver.
Show parts
Lookup Part! CD-VB-O-03M-TA-13 Celdek and V-Bank for Size # 3 Modular Supply unit with TA filters.For outdoor installation. MERV 13 V-Bank Filters. Includes Screened Intake
Show parts
Lookup Part! CD-VB-O-03M Celdek and V-Bank for Size # 3 Modular Supply unit. For outdoor installation. Includes Screened Intake
Show parts
Lookup Part! CD-VB-O-03M-IL Celdek and V-Bank for Size # 3 Modular Supply unit. For outdoor installation. Includes Intake Louver.
Show parts
Lookup Part! CD-I A3IF Celdek Evaporative Cooler for Size # 3 Modular Indirect-Fired Heater. 40.75" Wide x 38.125" Long x 43.375" High. For indoor installation. Min. water pressure for optimal performance is 30 PSI. Max. water pressure should not exceed 50 PSI. Use with water softener recommmended.
Show parts
Lookup Part! CD-O A3IF Celdek Evaporative Cooler for Size # 3 Modular Indirect-Fired Heater. 40.75" Wide x 72.313" Long x 43.375" High. Includes screened intake. For outdoor installation. Use with water softener recommended.
Show parts
Lookup Part! CD-O A3IF-IH Celdek Evaporative Cooler for Size # 3 Modular Indirect-Fired Heater. 40.75" Wide x 83.75" Long x 43.375" High. Includes intake hood with filters. For outdoor installation. Use with water softener recommended.
Show parts
Lookup Part! CD-O A3IF-NF Celdek Evaporative Cooler for Size # 3 Modular Indirect-Fired Heater. 40.75" Wide x 83.75" Long x 43.375" High. Includes intake hood without filters. For outdoor installation. Use with water softener recommended.
Show parts
Lookup Part! CD-O A3-IL Celdek Evaporative Cooler for Size # 3 Modular Un-tempered Supply Air Unit. 40.75" Wide x 72.313" Long x 43.375" High. Includes intake louver. For outdoor installation. Use with water softener recommended.
Show parts
Lookup Part! SI-3 Screen Intake for Size 3 Commercial Fans.
Show parts
Lookup Part! CD-O A3-2-IL Size # 3 Celdek Evaporative Cooler for Size # 2 Modular Un-tempered Supply Air Unit. 40.75" Wide x 72.313" Long x 43.375" High. Includes intake louver. For outdoor installation. Use with water softener recommended.
Show parts
Lookup Part! CD-O A4IF-3 Size # 4 Celdek Evaporative Cooler for Size # 3 Modular Indirect-Fired Heater. 47.813" Wide x 82.5" Long x 51.375" High. Includes screened intake. For outdoor installation. Use with water softener recommended.
Show parts
Lookup Part! CD-O A4IF-IH-3 Size # 4 Celdek Evaporative Cooler for Size # 3 Modular Indirect-Fired Heater. 47.813" Wide x 110.238" Long x 51.375" High. Includes intake hood with filters. For outdoor installation. Use with water softener recommended.
Show parts
Lookup Part! CD-O A4IF-NF-3 Size # 4 Celdek Evaporative Cooler for Size # 3 Modular Indirect-Fired Heater. 47.813" Wide x 110.238" Long x 51.375" High. Includes intake hood without filters. For outdoor installation. Use with water softener recommended.
Show parts
Lookup Part! CD-I A4IF-3 Size 4 Celdek Evaporative Cooler for Size # 3 Modular Indirect Fired Heater. 47.813" Wide x 35.188" Long x 51.375" High. For indoor installation. Min. water pressure for optimal performance is 30 PSI. Max. water pressure should not exceed 50 PSI. Use with water softener recommended.
Show parts
Lookup Part! CD-LPD-VB-O-04-3M-TA-13 Size 4 LPD Celdek and V-Bank for Size # 3 Modular Make Up Air unit. For outdoor installation. Includes Screened Intake
Show parts
Lookup Part! CD-LPD-VB-O-04-3M-TA-13-IL Size 4 LPD Celdek and V-Bank for Size # 3 Modular Make Up Air unit. For outdoor installation. Includes Intake Louver.
Show parts
Lookup Part! CD-LPD-VB-I-04-3M-HEPA Size 4 LPD Celdek and V-Bank for Size # 3 Modular Supply unit. For indoor installation.
Show parts
Lookup Part! CD-LPD-VB-I-04-3M-TA-13 Size 4 LPD Celdek and V-Bank for Size # 3 Modular Supply unit. For indoor installation.
Show parts
Lookup Part! CD-LPD-VB-I-04-3M-HE Size 4 LPD Celdek and V-Bank for Size # 3 Modular Supply unit. For indoor installation.
Show parts
Lookup Part! CD-LPD-VB-I-04-3M-TA Size 4 LPD Celdek and V-Bank for Size # 3 Modular Supply unit. For indoor installation.
Show parts
Lookup Part! CD-LPD-VB-I-04-3M Size 4 LPD Celdek and V-Bank for Size # 3 Modular Supply unit. For indoor installation.
Show parts
Lookup Part! CD-LPD-VB-IH-O-04-3M-TA Size 4 LPD Celdek and V-Bank for Size # 3 Modular Supply unit. For outdoor installation. Includes Intake Hood with 2" EZ filters
Show parts
Lookup Part! CD-LPD-VB-O-04-3M-HEPA Size 4 LPD Celdek and V-Bank for Size # 3 Modular Supply unit. For outdoor installation. Includes Screened Intake
Show parts
Lookup Part! CD-LPD-VB-O-04-3M Size 4 LPD Celdek and V-Bank for Size # 3 Modular Supply unit. For outdoor installation. Includes Screened Intake
Show parts
Lookup Part! CD-LPD-VB-O-04-3M-TA Size 4 LPD Celdek and V-Bank for Size # 3 Modular Supply unit. For outdoor installation. Includes Screened Intake
Show parts
Lookup Part! CD-LPD-VB-O-04-3M-HE Size 4 LPD Celdek and V-Bank for Size # 3 Modular Supply unit. For outdoor installation. Includes Screened Intake
Show parts
Lookup Part! CD-LPD-VB-O-04-3M-IL Size 4 LPD Celdek and V-Bank for Size # 3 Modular Supply unit. For outdoor installation. Includes Intake Louver.
Show parts
Lookup Part! CD-LPD-VB-O-04-3M-HE-IL Size 4 LPD Celdek and V-Bank for Size # 3 Modular Supply unit. For outdoor installation. Includes Intake Louver.
Show parts
Lookup Part! CD-LPD-VB-O-04-3M-HEPA-IL Size 4 LPD Celdek and V-Bank for Size # 3 Modular Supply unit. For outdoor installation. Includes Intake Louver.
Show parts
Lookup Part! CD-LPD-VB-O-04-3M-TA-IL Size 4 LPD Celdek and V-Bank for Size # 3 Modular Supply unit. For outdoor installation. Includes Intake Louver.
Show parts
Lookup Part! SFIH-03MID Sloped Filtered Intake for Size #3 Modular Indirect-Fired Heater. 37.25" Wide X 51.625" Long X 35.188" High. Includes 2" MV EZ Kleen Metal Mesh FIlter.
Show parts
Lookup Part! VB-I-03MIF-TA V-Bank for Size # 3 Modular Indirect-Fired Heater with TA filters. For indoor installation. MERV 8 V-Bank Filters.
Show parts
Lookup Part! VB-I-03MIF V-Bank for Size # 3 Modular Indirect-Fired Heater. EZ Metal Mesh Filters. For indoor installation.
Show parts
Lookup Part! VB-O-03MIF-TA V-Bank for Size # 3 Modular Indirect-Fired Heater with TA Filters. Includes screened intake. For outdoor installation. MERV 8 V-Bank Filters.
Show parts
Lookup Part! VB-I-03MIF-TA-13 V-Bank for Size # 3 Modular Indirect-Fired Heater with TA filters. For indoor installation. MERV 13 V-Bank Filters.
Show parts
Lookup Part! VB-O-03MIF-TA-13 V-Bank for Size # 3 Modular Indirect-Fired Heater with TA Filters. Includes screened intake. For outdoor installation. MERV 13 V-Bank Filters.
Show parts
Lookup Part! VB-O-03MIF V-Bank for Size # 3 Modular Indirect-Fired Heater. EZ Metal Mesh Filters. Includes screened intake. For outdoor installation.
Show parts
Lookup Part! VB-O-03M-HE V-Bank for Size # 3 Modular Make-Up Air unit with HE Filters. Includes screened intake. For outdoor installation. MERV 15 V-Bank Filters.
Show parts
Lookup Part! VB-O-03M-HE-IL V-Bank for Size # 3 Modular Make-Up Air unit with HE Filters. Includes intake louver. For outdoor installation. MERV 15 V-Bank Filters.
Show parts
Lookup Part! VB-O-03M-HEPA V-Bank for Size # 3 Modular Make-Up Air unit with HEPA filters. Includes screened intake. For outdoor installation.
Show parts
Lookup Part! VB-O-03M-HEPA-IL V-Bank for Size # 3 Modular Make-Up Air unit with HEPA filters. Includes intake louver. For outdoor installation.
Show parts
Lookup Part! VB-O-03M-TA-13-IL V-Bank for Size # 3 Modular Make-Up Air unit with TA Filters. Includes intake louver. For outdoor installation. MERV 13 V-Bank Filters.
Show parts
Lookup Part! VB-O-03M-TA-IL V-Bank for Size # 3 Modular Make-Up Air unit with TA Filters. Includes intake louver. For outdoor installation. MERV 8 V-Bank Filters.
Show parts
Lookup Part! VB-O-03M-IL V-Bank for Size # 3 Modular Make-Up Air unit. EZ Metal Mesh Filters. Includes intake louver. For outdoor installation.
Show parts
Lookup Part! VB-I-03M-HE V-Bank for Size # 3 Modular Supply unit with HE filters. For indoor installation. MERV 15 V-Bank Filters.
Show parts
Lookup Part! VB-I-03M-HEPA V-Bank for Size # 3 Modular Supply unit with HEPA filters. For indoor installation.
Show parts
Lookup Part! VB-O-03M-IH-EZ V-Bank for Size #3 Modular Indirect-Fired Heater with EZ Filters. Includes intake hood with EZ filters. For outdoor installation. Metal Mesh V-Bank Filters.
Show parts
Lookup Part! VB-O-03M-TA-13-IH-EZ V-Bank for Size #3 Modular Indirect-Fired Heater with TA Filters. Includes intake hood with EZ filters. For outdoor installation. MERV 13 V-Bank Filters.
Show parts
Lookup Part! VB-O-03M-HE-IH-EZ V-Bank for Size #3 Modular Make-Up Air unit with HE Filters. Includes intake hood with EZ filters. For outdoor installation. MERV 15 V-Bank Filters.
Show parts
Lookup Part! VB-O-03M-HEPA-IH-EZ V-Bank for Size #3 Modular Make-Up Air unit with HEPA filters. Includes intake hood with EZ filters. For outdoor installation.
Show parts
Lookup Part! VB-O-03M-TA-IH-EZ V-Bank for Size #3 Modular Make-Up Air unit with TA Filters. Includes intake hood with EZ filters. For outdoor installation. MERV 8 V-Bank Filters.
Show parts
Temperature Controls

No Temperature Controls Found.

Gas Manifold Parts

No Gas Manifold Parts Found.

Blower
Part
Lookup Part! 25Z-3-MOD 25 Inch Plenum Fan for size 3 MOD. Motor integral to Wheel. Max RPM = 1580.
Burner
Part
Lookup Part! IBT800-400-400 Bent Tube Furnaces - 800,000 BTU/HR maximum input, 640,000 BTU/HR maximum output, 53,333 BTU/HR minimum output for NG, 64,000 BTU/HR minimum output for LP. Includes (2) 400 MBH Input Furnaces. Stainless Steel Burner, Heat Exchanger, and Power Vent. No contols or sheet metal housing. Used in size 2,3,4, and 5 IBT.
 
Lookup Part!  - CP715IBT - [2 used] FURNACE - 400,000 BTU/HR Indirect Fired Bent Tube Furnace with Stainless Steel Heat Exchanger, Burner, and Power Vent. No contols or sheet metal housing. Indoor use only. Used in IBT.
Replacement Parts
Part
Lookup Part!  - [28 used] 33008 A0003208 - 3/8" WASHERS
Lookup Part!  - [3 used] 8003 CONDUIT CONNECTOR - 90deg; 1/2" Bridgeport, 1/2" long thread
Lookup Part!  - [2 used] B3DRSP AHU 3 DOOR SUPPORT
Burner and Burner Components
Lookup Part!  - [2 used] 5RS 5" MV Storm Collar
Lookup Part!  - [2 used] 5BVVTH 5'' DuraVent Type B High-Wind Cap. High Wind B Vent cap meets the UL standard for "high Wind" which is a 45 MPH test. Direct replacement for part number 5RHW and 5GVVTH.
Lookup Part!  - [4 used] 5RP12 B-Vent, 5 inch diameter, 12 inches long. Used in IBT.
Lookup Part!  - [2 used] 5RP18 B-Vent, 5 inch diameter, 18 inches long. Used in IBT.
Lookup Part!  - [2 used] 90416 High Temp Silicone Rubber Tubing for IBT power vent. Durometer=50, .25" OD, .125" ID, 450°F Max continuous temperature. Sold Per foot.
Lookup Part!  - [2 used] P5BT445 Square to Round Adapter Used on IBT Heaters. Adapts Power Vent to 5" Round B-Vent. Large Adapter.
Common Heater Components
Lookup Part!  - [1 used] HMI_Bracket 20 GA. Galvanized. Used on IBT controls
Common Heater Electrical Components
Lookup Part!  - [1 used] SU201M-K10 CIRCUIT BREAKER - 10 AMP Circuit Breaker Used for Indirect Heaters. Trip Curve D. UL489. Old P/N S201U-K10
Controller&HMI
Lookup Part!  - [1 used] HMI_01_IBT HMI assembly. Preprogrammed for use with IBT Board. Includes CASHMI PCB, 4 mounting screws, 16 ga. SS backing plate, membrane switches & gasket.
Direct Fired Air Movement Control Components
Lookup Part!  - [5 used] 8164 1/4" Nylon Tubing - Used with the Modular Make-Up Air Units A1-D, A2-D, A3-D, A4-D, A5-D and the NHMUA1, NHMUA2, NHMUA3, AI (Price Per Foot). Type 12.
Lookup Part!  - [1 used] 88130 1/4" Plastic Union Elbow for connecting airflow tubing to airflow probes (17045 & 17045A).
Direct Fired Sheet Metal Components
Lookup Part!  - [4 used] MD15LCOVER Door Louver Cover for Commercial DF 1-5 Units.
Lookup Part!  - [6 used] MLIFTL LIFTING LUG
Exhaust Fan Whiz Nuts & Bolts
Lookup Part!  - [8 used] 800043 A0005678 - Bolt Whiz 3/8-16 X 1 1/2, Steel Grade 5 Minimum (3 Evenly Spaced Radial Marks)
Lookup Part!  - [12 used] 0120763.0800 A0031100 - 1"L, 1/4-20 Matpoint, Self Aligning, Hex Head, Grade 5 Bolt
Lookup Part!  - [12 used] 11626-03224 Cage Nut - 1/4" - 20. Installed in 1/2" square hole. Used on 20 gauge material.
Lookup Part!  - [8 used] 5/16-18 WHIZNUT Zinc-Plated Grade 5 Steel Serrated-Flange Locknut, 5/16"-18 Thread Size, 11/16" Flange Diameter, 9/32" Overall Height.
Exhaust Fan Wiring Options
Lookup Part!  - [32 used] 8002 CONDUIT - 1/2" LT FLEX JIC. (Price per Foot)
Indirect Air Movement Control Components
Lookup Part!  - [1 used] RFS-4100-078 AIR FLOW SWITCH - Used for IBT air proving switch and clogged filter switch option. Factory set @ .25", adjustable.
Lookup Part!  - [2 used] NS2-1112-01 AIR FLOW SWITCH - Used with IBT units. Factory set @ .35". Induced draft fan airflow switch with bleed hole.
Indirect Fired Sheet Metal Components
Lookup Part!  - [1 used] IBT14HEEF IBT 1-4 HE END FLASHING
Lookup Part!  - [1 used] IBT15CBBT IBT 1-5 CABINET BOTTOM
Lookup Part!  - [1 used] IBT15ELBK IBT 1-5 ELECTRICAL BACK
Lookup Part!  - [2 used] IBT15ELSD IBT 1-5 ELECTRICAL SIDE
Lookup Part!  - [2 used] IBT15ELTP IBT 1-5 ELECTRICAL TOP
Lookup Part!  - [1 used] IBT15HC IBT 1-5 HAT CHANNEL
Lookup Part!  - [3 used] IBT15TD IBT 1-5 TIE DOWN
Lookup Part!  - [1 used] IBT15VFDB IBT 1-5 VFD BACK
Lookup Part!  - [1 used] IBT24HELFD IBT 2-4 HE LEFT FLASHING DOUBLE FURNACE
Lookup Part!  - [1 used] IBT24HERF IBT 2-4 HE RIGHT FLASHING
Lookup Part!  - [1 used] IBT24HE400TF IBT 24 HE 400 TOP FLASHING
Lookup Part!  - [1 used] IBT34SDSB IBT 3-4 Averaging Sensor Bracket
Lookup Part!  - [1 used] IBT34BOTTSD IBT 3-4 BOTTOM SIDE DISCHARGE
Lookup Part!  - [1 used] IBT34HEBOTSD IBT 3-4 HE BOTTOM SIDE DISCHARGE
Lookup Part!  - [1 used] IBT34HELID IBT 3-4 HE LID
Lookup Part!  - [4 used] IBT34HS IBT 3-4 HORIZONTAL SUPPORT
Lookup Part!  - [1 used] IBT35IWB IBT 3-5 INNER WALL BOTTOM
Lookup Part!  - [2 used] IBT35HE400IW IBT 3-5 INNER WALL FOR MODULE WITH 400 MBH FURNACE
Lookup Part!  - [1 used] IBT35DFLID IBT 3-5 LID DOUBLE FURNACE
Lookup Part!  - [2 used] IBT35MR IBT 3-5 MAIN RAIL
Lookup Part!  - [2 used] IBT15BDPN IBT Burner Condensate Drip Pan
Lookup Part!  - [2 used] IBTHE400ADS IBT HE 400 AIR DISTRIBUTION SCREEN
Lookup Part!  - [1 used] IBTHE400DIV IBT HE 400 DIVIDER
Indirect Flame Control Components
Lookup Part!  - [2 used] 35-615937-997 24VAC Direct Spark Ignition Control. Combustion blower relay, 15 second trial for ignition, 60 second pre-purge and inter-purge, 120 second post-purge, 3 trials for ignition Recycle on loss of flame remote flame sense. Special extended flame integration time.
Lookup Part!  - [2 used] 1-1437685-3-4 2TK2-48 Snap Track PVC Channel. 4 Inches Long.
Intakes & Accessories
Lookup Part!  - [1 used] DUCTBOARD DUCTBOARD 4X10 SHEET Owens Corning Type 475FRK Insulation. 1 Sheet.
Miscellaneous Electrical Parts
Lookup Part!  - [1 used] CAT5_3FT 3 Foot Long CAT5 Cable
Lookup Part!  - [2 used] 800041 Bolt Whiz 10-32 X 1/2, SFB103212Z, Steel Grade 5 Minimum (3 Evenly Spaced Radial Marks)
Lookup Part!  - [3 used] 8012A J-BOX - SWITCH BOX - CY X 1/2.
Lookup Part!  - [2 used] 800030 Nut Whiz 10-32, SFLN1032Z, Steel, Large Flange
Lookup Part!  - [2 used] FSCWIREHARNESS Wire Harness for IBT Board. 1 Required Per Furnace.
Miscellaneous Heater Components
Lookup Part!  - [6 used] NBB4000516 5/16" NUTS
Lookup Part!  - [10 used] WA4000516 5/16" WASHERS
Lookup Part!  - [1 used] 3M467J Captiveaire Factory Direct sticker
Lookup Part!  - [100 used] INSULATION/sq ft INSULATION (Price per Sq Foot)
Lookup Part!  - [16 used] HG-OTA100 Removable Door Hinge used on Pollution Control Units and KB Blowers
Miscellaneous Hood Parts
Lookup Part!  - [8 used] SCREW 10-24X3/8 ZINC RD HD SLOTTED MS - DOOR HANDLE SCREW 10-24X3/8 ZINC RD HD SLOTTED MS - Used on UC door handles and MUA door handles
Lookup Part!  - [1 used] 104778 SEALANT - 10.3 oz Silicone Silver/Aluminum Sealant. 350 deg silicone used in hoods. (item #104778)
Pollution Control Gasket
Lookup Part!  - [2 used] 397-91PSA-Foot Gasketing - Thermeez Woven Ceramic Tape - 1/4" x 1" with adhesive back - Max Temp 1500°F. To be applied between fan base and grease duct. Per Foot.
Product Manuals
Lookup Part!  - [1 used] MANUAL INDIRECT BENT TUBE Manual for Commercial Indirect Fired Bent Tube Heater
RTU Miscellaneous Components
Lookup Part!  - [8 used] A7-10-351-20 Black Compression Handle Latch and Clasp
Supply Fan Miscellaneous Parts
Lookup Part!  - [2 used] 2T4000516040000 5/16" BOLTS 4" LONG
Lookup Part!  - [116 used] SB6-4-RIVET RIVET - 3/16" Diameter, .126 To .250 Grip Range, SB6-4 Button Head Steel/Steel. Replaced 800075.
Lookup Part!  - [10 used] ITH41234 SHEET METAL SCREWS 12-14 X 3/4"
Supply Fan Sheet Metal Components
Lookup Part!  - [1 used] B3DDBAVP25Z A3 Direct Drive Blower Assembly Venturi Plate Ziehl
Lookup Part!  - [2 used] B3DDCZ A3 Direct Drive Collar Ziehl
Lookup Part!  - [1 used] B3DDDDLZ A3 Direct Drive Liner Ziehl
Lookup Part!  - [1 used] B3DDWGZ A3 Direct Drive Wheel Guard Ziehl
Lookup Part!  - [1 used] B3SDBKIBT AHU 3 BACK With View Port
Lookup Part!  - [1 used] B3DDC AHU 3 Direct Drive Discharge Collar
Lookup Part!  - [1 used] B3LIDDPRL AHU 3 LID w/Intergrated Drip Rail
Lookup Part!  - [2 used] B3MNRL AHU 3 MAIN RAIL
Lookup Part!  - [1 used] B3SDBKHDD AHU 3 Side Discharge Back Hinged Direct Drive
Lookup Part!  - [2 used] MCONWAS Connecting Washer 12 Gauge 2-7/8" x 2-7/8"
Lookup Part!  - [2 used] M3EFLS END FLASHING 37.9375X8 GALV18GA REV1
Lookup Part!  - [1 used] B3G18COL G18 COLLAR
Lookup Part!  - [3 used] M3HSUP HORIZONTAL SUPPORT
Lookup Part!  - [1 used] B3ULLD Lid Liner Blank for use with AHU-3 Insulation Liner Option.
Lookup Part!  - [1 used] MRDPLATE Rotary Disconnect Plate for Supply Fans. 16 GA G90 Galvanized.
Supply Fan Vibration Isolators
Lookup Part!  - [4 used] L1VIB Motor Frame Vibration Eliminator 1" Out. Dia. X 1/4" Tall, Rubber (Black) New Style, 5/16-18 x 1/2 dual studs. Durometer = 50
Thermostats/Sensors
Lookup Part!  - [1 used] A/CP-DO-240-QC 10K, Type II thermistor with 6" probe. 20' wire leads. (Replaces part# A/CP-DO-120-QC)
Lookup Part!  - [1 used] CP-HT-FA-12 High Temp 10K, Type II thermistor with average sensor wire 12' long operable up to 200F. No metal box included.
Lookup Part!  - [1 used] IBT Board Staging and Modulating PCB for IBT heaters. Includes control of multiple furnaces, forced high fire, modulation. Used in conjunction with CAS HMI. Not a direct replacement for FVFAB.
Transformers
Lookup Part!  - [1 used] BE161640GEK0018 TRANSFORMER - Low 40VA Voltage Transformer Used for 120v Primary and 24v Secondary.
Transformers (Heater Parts)
Lookup Part!  - [1 used] BE141620GEK0032 TRANSFORMER - 120V-24V 20VA with QC's Prod. 50/60Hz
Curbs
Part
Lookup Part! CRB35X84X8INS ROOF CURB - 35" Width X 84" Length X 8" Supply Height, Insulated
Lookup Part! CRB35X84X10INS ROOF CURB - 35" Width X 84" Length X 10" Supply Height, Insulated
Lookup Part! CRB35X84X12INS ROOF CURB - 35" Width X 84" Length X 12" Supply Height, Insulated
Lookup Part! CRB35X84X14INS ROOF CURB - 35" Width X 84" Length X 14" Supply Height, Insulated
Lookup Part! CRB35X84X15INS ROOF CURB - 35" Width X 84" Length X 15" Supply Height, Insulated
Lookup Part! CRB35X84X16INS ROOF CURB - 35" Width X 84" Length X 16" Supply Height, Insulated
Lookup Part! CRB35X84X18INS ROOF CURB - 35" Width X 84" Length X 20" Supply Height, Insulated
Lookup Part! CRB35X84X20INS-BTC BOLT TOGETHER ROOF CURB -35" X 84" X 20" High, Insulated. 18 GA Galvanized. Ships Flat. Pitched Curb Option Not Available with Bolt Together Curbs.
Lookup Part! CRB35X84X20INS ROOF CURB - 35" Width X 84" Length X 20" Supply Height, Insulated
Lookup Part! CRB35X84X22INS ROOF CURB - 35" Width X 84" Length X 22" Supply Height, Insulated
Lookup Part! CRB35X84X24INS CURB - 35" Width X 84" Length X 24" Supply Height, Insulated
Lookup Part! CRB35X84X28INS CURB - 35" Width X 84" Length X 28" Supply Height, Insulated
Lookup Part! CRB35X84X30INS CURB - 35" Width X 84" Length X 30" Supply Height, Insulated
Lookup Part! CRB35X84X31.375INS CURB - 35" Width X 84" Length X 31.375" Supply Height, Insulated
Lookup Part! CRB35X84X36INS ROOF CURB - 35" Width X 84" Length X 36" Supply Height, Insulated
Lookup Part! CRB35X84X40INS CURB - 35" Width X 84" Length X 48" Supply Height, Insulated
Lookup Part! CRB35X84X44INS CURB - 35" Width X 84" Length X 44" Supply Height, Insulated
Lookup Part! CRB35X84X48INS CURB - 35" Width X 84" Length X 48" Supply Height, Insulated
Options
Parts
Lookup Part! CSMDTIL Commercial Smoke Detector Interlock (Detector By Others)
Lookup Part! D4120-DST-1.5-C Duct Mounted Smoke Detector For Commercial Direct Fired Heater. Complete with detector (D4120) and sampling tube (DST-1.5). Ships Loose
Show parts
Lookup Part! CABHTR100WNC Control panel enclosure heater, includes 100w, 120v heater. Recommended for winter design temperature less than 0°F. Operates on PCB controls in IBT Single Modules or RTU
Show parts
Lookup Part! IBT Condensation Kit- 2 Factory Assembled IBT Condensation Drain Kit for 2 Furnace Units. Required for Winter Design Temp of 0 degrees F and lower. Kit includes drain assembly, mounting screws, zip ties, and heat tape for double furnace unit. Field piping from unit by others.
Show parts
Lookup Part! CWCM3-1 CW Coil Module for Size 3 Modular Fans - 3,000 thru 7,000 CFM (10 Ton, 5WS0604B-43.5x42.0) Not stocked. Allow 5-6 weeks lead time. Temperature controls, mixing valves, thermostats, and freeze protection by others.
Show parts
Lookup Part! CWCM3-2 CW Coil Module for Size 3 Modular Fans - 3,000 thru 7,000 CFM (15 Ton, 5WS1004B-43.5x42.0) Not stocked. Allow 5-6 weeks lead time. Temperature controls, mixing valves, thermostats, and freeze protection by others.
Show parts
Lookup Part! CWCM3-3 CW Coil Module for Size 3 Modular Fans - 3,000 thru 7,000 CFM (20 Ton, 5WS1204B-43.5x42.0) Not stocked. Allow 5-6 weeks lead time. Temperature controls, mixing valves, thermostats, and freeze protection by others.
Show parts
Lookup Part! CWCM3-4 CW Coil Module for Size 3 Modular Fans - 3,000 thru 7,000 CFM (25 Ton, 5WS1404B-43.5x42.0) Not stocked. Allow 5-6 weeks lead time. Temperature controls, mixing valves, thermostats, and freeze protection by others.
Show parts
Lookup Part! Ecoat-AC-3 Size 3 Cooling Coil Ecoating option for MPU-AC options. Adds 5-6 week lead time.
Lookup Part! Ecoat-3-C Size 3 Cooling Coil Ecoating option for standard MPU, DX and Chilled Water Coils. Adds 5-6 week lead time.
Lookup Part! DXM3-1 DX Coil Module for Size 3 Modular Fans - 3,000 thru 7,000 CFM (10 Ton - 2 Circuit DX Coil, 4EZ0602H-43.5x42.0) NOT BUILT WITH OPP SIDE CONTROLS. DXM3-1 Condenser and condenser disconnect (unless provided on quote) will be installed, started and warranted by others. R410A refrigerant and piping by others. Ensure DX-Kit is ordered for filter drier, sight glass, thermal expansion valve. (Old Heatcraft Coil # 5EJ0603B-43.5x42.0)
Show parts
Lookup Part! ECM Wiring Package- RTC (Ziehl) ECM Wiring Package and Manual or 0-10 VDC Control for Supply EC Ziehl Fans. RTC Controller
Show parts
Lookup Part! ECM Wiring Package- ECPM03 (Ziehl) ECM Wiring Package-Supply - PWM Signal from ECPMO3 Prewire (3 - Phase Ziehl Motor)
Show parts
Lookup Part! IBT-EC-FPDK-Evap Freeze Protection Drain Control kit for Evaporative Coolers. Includes 3-Way water solenoid valve 8316G064 (shipped loose), Pressure switch installed upstream of 2way solenoid in unit, Brass Tee and 2 NPT half inch nipples. Field wiring required by others for 3-way valve. For both Celdek and Standard V-bank type Configurations.
Show parts
Lookup Part! CD-G-36x30x12 Glasdek Media for size 3 celdek evaporative cooler intake. 36in wide x 30in tall x 12in thick.
Lookup Part! CD-G-43x38x12 Glasdek Media for size 4 celdek evaporative cooler intake. 43in wide x 38in tall x 12in thick.
Lookup Part! PRESSGA35 Gas Pressure Gauge, 0-35", 2.5" Diameter, 1/4" Thread Size
Lookup Part! PRESSGA-0-10-2 Gas Pressure Gauge, 0 to +10 Inches Wc., 2.5" Diameter, 1/8" Thread Size, Rear Thread, For 2 Furnaces
Show parts
Lookup Part! 143-80-2-1-G-5/8 Gas regulator - 1" diameter thread size, 10 PSI Inlet Gas Pressure. 1180 CFH, 6-14" w.c. Outlet Pressure. Includes 173-62-021-17 "Green" spring and 5/8" 10 PSI orifice.
Lookup Part! HGP-A-2 High Pressure Gas Switch (2" - 16" WC) Factory set at 5" w.c. (Natural) or 12" w.c. (L.P.) 2 Switches for Indirects with 2 Furnaces.
Show parts
Lookup Part! LGPSO Low Pressure Gas Switch (1" - 6" WC) Factory set at 2" w.c.
Show parts
Lookup Part! MIAMI-DADE NOA-2 Supply Miami Dade Impact and Wind Load Certification +30 / -130 PSF - Miami Dade County Product Control Approved. Florida Building Code approval. Roof Mount Exhaust Curbs up to 20" high must be 18 gauge Aluminized.
Lookup Part! Single Point Connection - 1 Single Point Electrical Connection for all IBT Heaters with 1 module. QNTY 1 750va Transformer Used. If a Non-DCV Prewire is used on the IBT Heater, the #28, #47, "MA", or "E2" Option Prewire must be selected. Do not provide supply starter in prewire.
Lookup Part! Separate 120V Connection - 1 Separate 120V Electrical Connection for all IBT Heaters with 1 module for Standing power. 120V must be run by electrician from building panel to mua switch.
Lookup Part! IBT EVAP INTERLOCK Layer Control for IBT Evap
Show parts
Lookup Part! IBT ROOM OVERRIDE Option Control for IBT/RTU Scheduling. Do not order as a part.
Lookup Part! IFHIELOR Specially sized orifices for applications above 2,000', notify engineering.
Show parts
Lookup Part! IHC-IDF3 Indoor Hanging Cradle For The Size 3 Indirect Fired Unit. 2 HSA310 Hanging Isolators per Uni-Strut Included.
Show parts
Lookup Part! Blower Delay Start Blower Delay Start. Allows Indirect Furnace to pre-heat before blower operation. Factory set at 90 seconds. TI-11 set at 20 seconds. TI-12 set at 90 seconds.
Lookup Part! Burner-Interlock-IBT/RTU Burner Interlock Input. Locks out cooling when interlock is energized.
Lookup Part! CLCOMM_REV04 CASLink building monitoring system communications module. Requires internet & field wired ethernet connection or 3G cellular service. Includes Rev 3 Comm Module, RJ45 to modbus converter, 3 FT cat5 cable, and 1 FT of shielded twisted pair.
Show parts
Lookup Part! AC-Interlock-IBT/RTU Cooling Interlock Input to PCB Board. Locks out burner circuit when AC is energized.
Lookup Part! DDC-IP BACnet Monitoring Remote IP BACnet monitoring for supply fans.
Show parts
Lookup Part! DDC-LONWorks Monitoring Remote LONWorks monitoring for supply fans.
Show parts
Lookup Part! DDC-MSTP BACnet Monitoring IBT Remote MSTP BACnet monitoring for IBT
Show parts
Lookup Part! FECONTAAFS Field Wired Exhaust Contactor After Airflow Switch. Rated 23 Amps. Starts up to (2) Single Phase Motors. 2HP max. 115V, 3HP max. 240V. Starts one Three Phase Motor. 5HP max. 208V, 7.5HP 230v, 15HP max. 460V, 15HP max. 575V or (4) Dry Interlocks. Overload not Included
Show parts
Lookup Part! FECONTBAFS Field Wired Exhaust Contactor Before Airflow Switch. Rated 23 Amps. Starts up to (2) Single Phase Motors. 2HP max. 115V, 3HP max. 240V. Starts one Three Phase Motor. 5HP max. 208V, 7.5HP max 230v, 15HP max. 460V. Overload not Included
Show parts
Lookup Part! EXHSTARTER1-3AAFS Exhaust Fan Starter Installed in size 1, 2, or 3 heater powered after airflow swtich
Lookup Part! EXHSTARTER1-3BAFS Exhaust Fan Starter Installed in size 1, 2, or 3 heater powered before airflow switch
Lookup Part! Exhaust on Fire Exhaust on Fire
Lookup Part! OCCUPIED SCHEDULING Occupied Scheduling Defaulted for IBT/RTU.
Lookup Part! OPPSIDE-H-CTRLS Mount motor and controls on opposite side of heater.
Lookup Part! Supply Fan Preset Speed Supply Fan Preset Speed Input to PCB. Field Wired.
Lookup Part! UNOCCUPIED SCHEDULING Unoccupied Scheduling Defaulted for IBT/RTU.
Lookup Part! CLOGFILTHMI Clogged Filter Switch with Notification on HMI
Show parts
Lookup Part! CVOUTLET GFCI 15 amp Convenience Outlet For Heater Enclosure. Power supply by others - Includes receptacle and J box.
Lookup Part! EXTENDED-DROP Extended Drop for Commercial Heaters and Supply Fans. Extends the power and remote panel connections to the unit to 20' of total length.
Lookup Part! CVOUTLET6IBT3 GFCI 6 amp Powered Convenience Outlet For IBT 3 units with 208/230/460 power. Includes receptacle, jbox, cover, and transformer.
Show parts
Lookup Part! Single Electrical Cabinet LED Lights Single Electrical Cabinet LED Lights Used on Modular MUA Units
Show parts
Lookup Part! MB3-MPU Support shell for Size 3 Modular Package Unit. Includes control vestibule. Includes condenser supports. Does not include return air or inlet air damper.
Show parts
Lookup Part! MB3-MPU-3-15 Support shell for Size 3 Modular Package Unit for Third Condenser. Includes control vestibule. Includes condenser supports. Does not include return air or inlet air damper.
Show parts
Lookup Part! MB3-IBT-Analog Mixing Box for Size 3 IBT. Actuator Control By 0-10V Input to IBT Board by others.
Show parts
Lookup Part! MB3-IBT-2P Mixing Box for Size 3 IBT. Actuator Control By Field Wired Switch.
Show parts
Lookup Part! MB3-IBT-MAN Mixing Box for Size 3 IBT. Actuator Control By 0-10V Output on IBT Board.
Show parts
Lookup Part! MB3-IBT-OA Mixing Box for Size 3 IBT. Actuator Control By 0-10V Output On IBT Board to Maintain Desired Outdoor Air %.
Show parts
Lookup Part! MB3-IBT-SCHEDULE Mixing Box for Size 3 IBT. Actuator Control By Schedule.
Show parts
Lookup Part! MB3-SP Mixing Box for Size 3 Modular Supply Fan. Actuator Control by Static Pressure. Photohelic included.
Show parts
Lookup Part! A3IBTUPDISCH Up Discharge Construction Size 3 IBT
Lookup Part! Shaft Grounding Ring Option Shaft Grounding Ring Option
Lookup Part! A3-D-MBDD INS Motorized Back Draft Insulated Damper 30" X 30" for Size 3 Standard & Modular Heater Units w/Extended Shaft, Standard Galvanized Construction, 3/4" Rear Flange, Low Leakage, NFBUP-S Actuator Included. Insulated blades and frame. Thermally broken blades.
Show parts
Lookup Part! A3-D-MBDD Motorized Back Draft Damper 30" X 30" for Size 3 Standard & Modular Heater Units w/Extended Shaft, Standard Galvanized Construction, 3/4" Rear Flange, Low Leakage, NFBUP-S Actuator Included
Show parts
Lookup Part! A3-MBDD-SL Motorized Back Draft Discharge Damper Shipped Loose 30" X 30" for Size 3 Units w/Extended Shaft, Standard Galvanized Construction, 3/4" Rear Flange, Low Leakage, NFBUP-S Actuator Included, Field Installation Required. Damper, actuator & actuator cover (p/n ACTCOVERMOD) factory assembled.
Show parts
Lookup Part! Full Crating for Heater Full crating for commercial heaters for shipping.
Lookup Part! ENAM-2 Tan Enamel Coating (exterior walls/roof) For Heaters with 18"-20" blower wheels, casing and intakes. Consult factory for other colors. Sherwin Williams p/n F75KXN5809-4347, (AX = A0006229)
Lookup Part! Condenser_Locking_Caps_2 Locking caps for double condenser units. Consists of 4 locking caps, part# NCP-4, and 1 key, part# NC-KEY.
Show parts
Lookup Part! Condenser_Locking_Caps_3 Locking caps for triple condenser units. Consists of 6 locking caps, part# NCP-4, and 1 key, part# NC-KEY.
Show parts
Lookup Part! DX 3-1 KIT-R410A DX 3-1 Kit R410A. Dual Circuit 10 Ton. Includes Filter Drier, Sight Glass, and Thermal Expansion Valve for DX units. Installation by others. Includes R410A TXV. Installation by others. Includes R410A TXV.
Show parts
Lookup Part! DX 3-2 KIT-R410A DX 3-2 Kit R410A. Dual Circuit 15 Ton. Includes Filter Drier, Sight Glass, and Thermal Expansion Valve for DX units. Installation by others. Includes R410A TXV. Installation by others. Includes R410A TXV.
Show parts
Lookup Part! DX 3-3 KIT-R410A DX 3-3 Kit R410A. Dual Circuit 20 Ton. Includes Filter Drier, Sight Glass, and Thermal Expansion Valve for DX units. Installation by others. Includes R410A TXV. Installation by others. Includes R410A TXV.
Show parts
Lookup Part! DX 3-4 KIT-R410A DX 3-4 Kit R410A. Dual Circuit 25 Ton. Includes Filter Drier, Sight Glass, and Thermal Expansion Valve for DX units. Installation by others. Includes R410A TXV. Installation by others. Includes R410A TXV.
Show parts
Lookup Part! MELIM-3-10-AC MPU3-10-AC Moisture Eliminator Option - allows cooling coil face velocity to increase to 650 fpm. Increases cooling coil max cfm to 4550 cfm.
Show parts
Lookup Part! MELIM-3-15-AC MPU3-15-AC Moisture Eliminator Option - allows cooling coil face velocity to increase to 650 fpm. Increases cooling coil max cfm to 5650 cfm.
Show parts
Lookup Part! ShipLoose-1C-1PH Ship Condenser Loose - Single Condenser, Single Phase - Condenser Disconnect Shipped Loose. All piping and wiring between indoor and outdoor units by others.
Show parts
Lookup Part! ShipLoose-1C-3PH Ship Condenser Loose - Single Condenser, Three Phase - Condenser Disconnect Shipped Loose. All piping and wiring between indoor and outdoor units by others.
Show parts
Lookup Part! ShipLoose-3C-1PH Ship Condensers Loose - Three Condensers, Single Phase - Condenser Disconnects Shipped Loose. All piping and wiring between indoor and outdoor units by others.
Show parts
Lookup Part! ShipLoose-3C-3PH Ship Condensers Loose - Three Condensers, Three Phase - Condenser Disconnects Shipped Loose. All piping and wiring between indoor and outdoor units by others.
Show parts
Lookup Part! ShipLoose-2C-1PH Ship Condensers Loose - Two Condensers, Single Phase - Condenser Disconnects Shipped Loose. All piping and wiring between indoor and outdoor units by others.
Show parts
Lookup Part! ShipLoose-2C-3PH Ship Condensers Loose - Two Condensers, Three Phase - Condenser Disconnects Shipped Loose. All piping and wiring between indoor and outdoor units by others.
Show parts
Lookup Part! SP-MPU-2C Single Point MPU Connection, 2 Condensers.
Show parts
Lookup Part! SP-MPU-3C Single Point MPU Connection, 3 Condensers.
Show parts
Lookup Part! MELIM-3 Size 3 Moisture Eliminator Option for DX Coils, MPUs, and Chilled Water Coils - allows cooling coil face velocity to increase to 650 fpm. Increases cooling coil max cfm to 8150 cfm.
Show parts
Lookup Part! MPU3-10-RH Size 3, 10 Ton MPU Reheat Option. Reheat uses warm liquid refrigerant. Reheat runs continuously in stage 1 circuit. Option should not be used if entering air dew point is below 65 degrees F. Nominal Capacity 15.3 MBH. Increases max CFM to 4550.
Show parts
Lookup Part! Damper Presets Damper Preset Position Input to PCB. Field Wired.
Show parts
Lookup Part! D-Hanger Curb Duct Hanger - 1-1/4" Angle Iron Frame Welded to Curb to support standard size ductwork. Priced per curb. Only available when curb assembly is ordered.
Lookup Part! MB3-MERV 13-EXTRA Extra set of MERV 13 filters for Size 3 Mixing Box. Uses 4 15 x 20 x 2 inch filters and 2 15 x 15 x 2 inch filters.
Show parts
Lookup Part! MB3-MERV 8-EXTRA Extra set of MERV 8 filters for Size 3 Mixing Box. Uses 4 15 x 20 x 2 inch filters and 2 15 x 15 x 2 inch filters.
Show parts
Lookup Part! MB3-MERV 13 MERV 13 filter option for Size 3 Mixing Box or Condenser Support. Mixing Box or Condenser Support must be selected for this option. Uses 4 15 x 20 x 2 inch filters and 2 15 x 15 x 2 inch filters.
Show parts
Lookup Part! MB3-MERV 8 MERV 8 filter option for Size 3 Mixing Box or Condenser Support. Mixing Box or Condenser Support must be selected for this option. Uses 4 15 x 20 x 2 inch filters and 2 15 x 15 x 2 inch filters.
Show parts
Lookup Part! Dedicated Combustion 8 inch Round Take-Off Installed in Lid of IBT for dedicated combustion air on indoor units. Control side door constructed without louvers. All combustion ductwork by others.
Show parts
Lookup Part! Ship Modules Separate Ship Modules Separate Option for Modular Units
Lookup Part! MB3-TOPRN Top Return Option for Size 3 Mixing Box - No Filter Option Available. Use top return lid and standard DF base.
Show parts
Lookup Part! FIRESTAT-DISCHARGE- Discharge Firestat. Set to 240°F
Lookup Part! FREEZESTAT- Freezestat factory set at 35°F and 10 minutes.
Lookup Part! FIRESTAT-INTAKE- Intake Firestat. Set to 135°F
Lookup Part! IBT/DF/RTU Nema 4x remote Space Sensor Nema 4x Remote Room Sensor Option. Wall Mountable 10k Room Sensor Included.
Show parts
Lookup Part! IBT/RTU remote Space Sensor Remote Room Sensor Option. Wall Mountable 10k Room Sensor Included.
Show parts
Lookup Part! Blower Delay Stop Blower Delay Stop. Allows supply fan to run after the burner has shut off Factory set at 90 secs for indirect 30 secs for direct.
Lookup Part! VBI-CSF "Insulation" for V-bank Intake Option.
Lookup Part! VB-DS-MB3 V-bank Downstream of Mixing-Box Option Size 3
Lookup Part! DCVWP-SUPPLY Separate 120VAC Wiring Package for Make-Up Air Units. Option must be selected when mounting VFD in prewire panel or with DCV package. Provides separate 120VAC input to supply fan. This 120V signal must be run by electrician from DCV to mua switch.
Show parts
Lookup Part! VAV-WP-VDC-INPUT-MUA VAV (Variable-Air-Volume) Wiring Package for Commercial Fans. 0-10VDC Speed Control Variable Frequency Drive Included
Lookup Part! VAV-WP-BSPC-MUA VAV (Variable-Air-Volume) Wiring Package for Commercial Fans. Building Static Pressure Variable Frequency Drive Control Included
Show parts
Lookup Part! VAV-WP-MC-MUA VAV (Variable-Air-Volume) Wiring Package for Commercial Fans. Manual Speed Control Variable Frequency Drive Included
Lookup Part! VFDINUNIT VFD factory mounted and wired in unit control vestibule.