Rep Our Products

Are you interested in representing CaptiveAire and selling our products?
Please fill out the following form, and we will contact you soon.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

 
     
  Parts > Commercial & Industrial Fans > Heaters & Heater Components > Direct Fired Components > Direct Fired Electrical Componets > Direct Fired Modulating System Components  
     

Sort by:   
 
 Direct Fired Modulating System Components
 
     
CaptiveAire Systems
www.captiveaire.com
     
** Please call for pricing or to purchase **
 
Part # & Description
Lookup Part!  - A-306
Static Pressure Kit for Photohelic, contains 1/8" id tubing, fittings and outdoor sensor.

Lookup Part!  - MP2
MP2 series kit. Includes programmable temperature selector (P/N TDM02) and temperature control amplifier (P/N AM02). Sold as set.

Lookup Part!  - SC-1
SIGNAL CONDITIONER - RTC Temperature Modulating System 4-20ma or 2-10vdc, used with TS-01 Discharge Air Sensor. Integral Low Fire Start.

 
     
Maxitrol
www.maxitrol.com
     
** Please call for pricing or to purchase **
 
Part # & Description
Lookup Part!  - 1094C-1050
100-500° F High Temperature Amplifier

Lookup Part!  - A1014R
Maxitrol 14 Temperature Regulation System Used on Heaters for Series 14. Integral low fire start, multiple temp ranges (stickers included for amp dial), integral dial, can be used with or without remote temp dial. Can replace A1014, A1014L1, AD1014, AD1014L1, A1014U, AD1014U.

Lookup Part!  - A1044R
A1044 MODULATING AMPLIFIER - Maxitrol 44 Temperature Regulation System on Heaters for Series 44 with 40 - 140 degree temperature range, Integral Low Fire Start, Powered LED and Valve Output LED.

Lookup Part!  - ES356A
Maxitrol series 44 amplifier, min setting range 40-80, max setting range 80-180. Minimum order quantity 10 - special order.

Lookup Part!  - ES356TS
Maxitrol series 44 discharge air sensor, used with mixing tube, 40-80 degree temp range

Lookup Part!  - ES394-3B-48FQ
Series 94 High Temp Discharge Sensor used with a1094 and a1494 amplifiers and "M" series programmable. 3" X .19" diam probe, not used with mixing tube.

Lookup Part!  - KT/M420B2
Replacement modulating head kit, includes head (includes coil) and plunger for MR212 D, E, G, J valves

Lookup Part!  - T244
TEMPERATURE SELECTOR T244 - Maxitrol "Selectrastat 55-90" 44 temperature regulation

Lookup Part!  - T244A
Maxitrol series 44 sensor/set point, 40-80 degree temp range

Lookup Part!  - TD114
TD 114 Temp Dial Discharge Setpoint with range of 55-90 degree

Lookup Part!  - TD114A
TD114A Temp Dial with range of 80-130 Degree.

Lookup Part!  - TD114B
Temp Dial with 120-170 Degree Range

Lookup Part!  - TD114F
TD114F Temp Dial with range of 40-80 Degree.

Lookup Part!  - TD114G
Maxitrol series 14 temperature setpoint dial, 90-140 degrees.

Lookup Part!  - TD114S
Dual Temp Selection Dials (55-90 & 90-140) and range selection switch mounted in an enclosure.

Lookup Part!  - TD214B
Dual Temp Dials 55-90 and 120-170 Range

Lookup Part!  - TD214G
Dual Temp Dials 55-90 and 90-140 Range

Lookup Part!  - TD244
TD244 Temp Dial (Setpoint) only (used in series 44 split system)

Lookup Part!  - TD294E-609-0818
Digital Series 94 Dual Dial Temp Setpoint 60-90f, 80-180f

Lookup Part!  - TM02
"MP2" series auxillary multi-function timer. To be matched with AM02 "MP2" series amplifier.

Lookup Part!  - TS114
TS114 DISCHARGE AIR SENSOR - Maxitrol 14 Temperature Regulation System, Discharge Sensor with a range of 55-90 degree

Lookup Part!  - TS114A
TS114A TEMPSENSOR 80-130 RANGE.

Lookup Part!  - TS114B
TS114B Discharge Sensor with range of 120-170 degree

Lookup Part!  - TS114F
TS114F Temp Sensor with range of 40-80 Degree.

Lookup Part!  - TS144
DISCHARGE AIR SENSOR - Maxitrol 44 temperature regulation system (TS144). (min-> 40 to 80 F | max-> 80 to 140 F).

Lookup Part!  - TS194Q
Series 94 Discharge Temp Sensor used with a1094 and a1494 amplifiers and "M" series programmable

Lookup Part!  - TS214B
Series 14 discharge air sensor used with TD214B dual dial 55-90, 120-170f

Lookup Part!  - TS214G
Maxitrol series 14 discharge air sensor for dual dial, 55-90, 90-140 degrees

Lookup Part!  - TS244
TS244 Temp Room Sensor Only (used in series 44 split systems) 55-90 Degrees.

Lookup Part!  - TS244-ES02
Epoxy coated TS244 with 18" leads, Temp Sensor as per ES225.

Lookup Part!  - TS394-3B48FQ
Discharge RTD air sensor 3" X .19" PROBE. Used for a high temp sensor 100-500 degree range.

 
     
RTC Solutions
www.rtc-solutions.com
     
** Please call for pricing or to purchase **
 
Part # & Description
Lookup Part!  - DFC-X
MODULATING AMPLIFIER - RTC Solutions Temperature Regulation System. Used on Direct-Fired Heaters with Integrated 40-90deg set point dial and low fire start. Can also be coupled with remote dial. Replaces DFC-1 & DFC-2.

Lookup Part!  - DFTD
DFTD Temp Dial Discharge Setpoint with 5 selectable temperature ranges. (40-90 deg), (80-130deg), (120-170deg), (160-210deg), (200-250deg).

Lookup Part!  - TS-01
DISCHARGE AIR SENSOR - RTC Solutions Temperature Regulation System, Discharge Sensor with a range of 40-250 degree. Direct Replacement for DFTS.