Parts > Kitchen Ventilation > Heaters & Heater Components > Direct Fired Components > Direct Fired Gas Train Components > Commercial Direct Fired Burners-Aluminum  
     

Sort by:   
 
 Commercial Direct Fired Burners-Aluminum
 
     
Midco
     
** Please call for pricing or to purchase **
 
Part # & Description
Lookup Part!  - HMA-2A-12-A
Direct-fired burner assembly. 550,000 BTU/HR Maximum, 18,333 BTU/HR Minimum. Aluminum Casting with SS Baffles. 12" long. Used in size 1 & 2 direct-fired heater. Used for both Natural and Propane Gas. Pilot/Flame Rod/Spark Assembly included.

Lookup Part!  - HMA-2A-18-A
Direct-fired burner assembly. 825,000 BTU/HR Maximum, 27,500 BTU/HR Minimum. Aluminum Casting with SS Baffles. 18" long. Used in size 2 & 3 commercial direct-fired heater. Used for both Natural and Propane Gas. Pilot/Flame Rod/Spark Assembly included.

Lookup Part!  - HMA-2A-24-3-A
Direct-fired burner assembly. 1,100,000 BTU/HR Maximum, 36,666 BTU/HR Minimum. Aluminum Casting with SS Baffles. 24" long. Used in size 3 commercial direct-fired heater. Used for both Natural and Propane Gas. Pilot/Flame Rod/Spark Assembly included.

Lookup Part!  - HMA-2A-24-4-A
Direct-fired burner assembly. 1,100,000 BTU/HR Maximum, 36,666 BTU/HR Minimum. Aluminum Casting with SS Baffles. 24" long. Used in size 4 commercial direct-fired heater. Used for both Natural and Propane Gas. Pilot/Flame Rod/Spark Assembly included.

Lookup Part!  - HMA-2A-30-A
Direct-fired burner assembly. 1,375,000 BTU/HR Maximum, 45,833 BTU/HR Minimum. Aluminum Casting with SS Baffles. 30" long. Used in size 4 commercial direct-fired heater. Used for both Natural and Propane Gas. Pilot/Flame Rod/Spark Assembly included.

Lookup Part!  - HMA-2A-48-A
Direct-fired burner assembly. 2,200,000 BTU/HR Maximum, 73,333 BTU/HR Minimum. Aluminum Casting with SS Baffles. 48" long-"H" Shaped. Used in size 5 modular and standard direct-fired heater. Used for Natural Gas and Propane. Pilot/Flame Rod/Spark Assembly included.

Lookup Part!  - HMA-2A-6-A
Direct-fired burner assembly. 275,000 BTU/HR Maximum, 13,000 BTU/HR Minimum. Aluminum Casting with SS Baffles. 6" long. Used in size 1 compact & commercial direct-fired heater. Used for both Natural and Propane Gas. Pilot/Flame Rod/Spark Assembly included.

Lookup Part!  - HMA-2A-6-A-D76
Direct-fired burner assembly. 275,000 BTU/HR Maximum, 13,000 BTU/HR Minimum. Aluminum Casting with SS Baffles. 6" long. Used in size 1 compact & commercial direct-fired heater. Used for both Natural and Propane Gas. "Brute" Pilot/Flame Rod/Spark Assembly included. Used in D76.

Lookup Part!  - HMA-2A-60-A
Direct-fired burner assembly. 2,750,000 BTU/HR Maximum, 91,667 BTU/HR Minimum. Aluminum Casting with SS Baffles. 60" long-"H" Shaped. Used in size 5 modular and standard direct-fired heater. Used for Natural Gas and Propane. Pilot/Flame Rod/Spark Assembly included.